• Title/Summary/Keyword: Expansion rate

Search Result 1,398, Processing Time 0.028 seconds

Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants (친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측)

  • Roh, Geun-Sang;Kim, Jong-Ryeol
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.2
    • /
    • pp.301-306
    • /
    • 2013
  • In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.

Changes in Physico-Chemical Properties of Burley Leaf Tobacco by Expansion Process. (팽화처리에 의한 Burley종의 물리화학적 특성변화)

  • 김병구;김기환;임광수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.2
    • /
    • pp.144-151
    • /
    • 1999
  • This study was carried out to compare the change physico-chemical properties in the 10 grades of Burley leaf tobacco expanded by $CO_2$. The filling capacity of AB3T was increased from 5.44cc/g to 9.52cc/g with the expansion rate 75.0% and that of CD3W was increased from 5.57cc/g to 10.16cc/g with the expansion rate 82.4%. But the rate of cut tobacco longer than 3.36 mm decreased from 77.2% to 49.9% and from 67.3% to 41.2% in grade B1T and C1W, respectively. The contents of nicotine and total volatile base in the of expanded cut tobacco decreased 11.9% and 10.4% respectively. The contents of onganic acids, except oxalic and palmitic acid, essential oil, amino acids, nicotine, tar and ammonia contents in the cigarette smoke decreased by expansion procecs. These results suggest that expanded tobacco was very useful to make less irritative cigarettes.

  • PDF

An Ergonomic Study on Functional Utility of Movement in Sleeves (소매의 동작기능성에 관한 인간공학적 연구)

  • 최해주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.5
    • /
    • pp.826-841
    • /
    • 1995
  • This study is concerned with the functional utility of movement in sleeve from an ergonomic viewpoint. Experiments were carried out which include 43 upper extremity segments, 21 motions and 35 female subjects. The major conclusions of the study are. 1. The expansion rate of upper extremity was higher in length than in circumference mesurements. The amounts of expansion were, especially high (more than 60mm) for inner arm length, axillary arm circumference, and outer arm length. Therefore, a lot of ease is necessary for these parts. On the other hand, armhole circumference, forearm circumference, and wrist circumference had low rates of expansion. The sleeve cap length was also contracted in all motions. 2. The expansion rate and the range of expansion and contraction were higher in the upper arm than in the forearm. The main points of expansion were the axillary and elbow parts. The segment of maximum expansi (rate of 44.8%) was Iii of axillary parts. As the body surface expands mainly in some segments, it is desirable to allow ease to the main segments of expansion. 3. In a basic sleeve, necessary ease was lacking in the measurements for outer arm length and axillary arm circumference, while it was too large in armhole circumference, forearm circumference, wrist circumference, and sleeve cap length. Therefore, a basic sleeve is inadequate as a functional sleeve for hard work in point of functional utility of movement. Wider application of these findings would lead to an improvement in the comfort of workers.

  • PDF

The Relation between Hydrogen absorption and Expansion behavior in the Rolled Plate (압연가공판재의 수소저장과 팽창거동과의 관계)

  • Jung, Young-Guan;Kim, Kyoung-Hoon;Lee, Keun-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.12 no.2
    • /
    • pp.121-128
    • /
    • 2001
  • In order to study the relation between expansion of the specimen and the hydrogen absorption rate, thin palladium plates with cold rolling were used. Thin palladium plates were hydrogenated in the 0.1mol $H_2SO_4$ electrolyte by electrochemical method. The expansion behavior on hydrogen absorbing can be obtained by X-ray diffraction analysis and by micrometer measurement It is noted that the expansion rate of Palladium specimens in thickness direction is larger than in length and width direction. The lattice constants increase quickly with increasing hydrogen absorbing rate up to 0.5, but above the rate they keep constant. Also the clues for plastic deformation, such as slip lines and voids, were observed in abundantly even though the plates were hydrogenated once.

  • PDF

A Study on the Application Medium Expansion Foam Extinguisher by a Fire Performance Analysis used Medium Expention Foam Agent (중발포 소화약제 소화성능 분석을 통한 중발포기 적용에 관한 연구)

  • Lee, Jang Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.402-408
    • /
    • 2019
  • Purpose: The study want to verify application the medium expantion foam extinguisher of expantion foam rate and fire extinguishing Performance test because the medium expansion system can maintain the discharge distance less affected by air currents, and the foam agent can be used efficiently. Method: For the study, the medium-expansion testing apparatus was manufactured and with synthetic surfactant foam agent of (class B) fire extinguishing model, and Fire Performance was analyzed for foam expansion rate and the fire agent consumption was measured and analyzed. Results: We measured the medium-spray testing apparatus and found that the expansion rate was 26.1 times. The test results of a 20-unit fire extinguishing model show that the extinguishing time is faster than the high and low foam expansion. It has been analyzed that it is possible to apply a hand-operated with a hose reel or medium expansion apparatus. Conclusion: Considering that the foaming agent and the extinguishing performance of the medium foam ratio are excellent, It is necessary to introduce the technical standards of medium foam agent for the introduction of hand-operated equipment, such as hose reel or portable medium foam apparatus.

The comparison research of the setting expansion and surface condition by using method of dental stone (치과용 경석고의 사용방법에 따른 경화팽창과 표면상태 비교연구)

  • Park, Soo-chul;Nam, Sang-young;Jung, In-ho
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.263-272
    • /
    • 2016
  • Purpose: The purpose of this study is to measure and compare a degree of setting expansion of dental stone by time depending on the mixing methods and mixing ratios of dental stone, to compare the surface state of each specimen with the use of an optical camera with microscope, and thereby to provide a fundamental material for making dental prostheses. Methods: The test on setting expansion of dental stone is based on ISO 6873. With two different mixing ratios and three kinds of stone mixing methods, test groups were created, and a total of six types of specimens (N=30) were made. Based on the specimens, the setting expansion rate of each one was measured in each time slot of 24 hours, and the surface of the set stone was measured. Results: According to the analysis on setting expansion rate of stone, the setting expansion of the specimen that was created in the way of vacuum mixing at normal mixing ratio was 0.1944% at 120 minutes; the setting expansion of the specimen that was created in the way of vacuum mixing at the mixing ratio which was 40% higher than normal mixing ratio was 0.195% at 120 minutes; the setting expansion of the specimen that was created in the way of mixing with hands at normal mixing ratio and then removing bubbles in vacuum mixer was 0.196% at 120 minutes. Conclusion: The setting expansion rate of each dental stone specimen was significantly different with the lapse of time up to 24 hours(p<.001).

A Study on the Movement-Fitness according to the Surface changing of Lower-Limb -On the Movements and Shapes of Lower-limb- (하복의 체표변화에 따른 동작적합성에 관한 연구 -하복동작 및 체형을 중심으로-)

  • 박영득;서영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.2
    • /
    • pp.257-269
    • /
    • 1996
  • The puropose of this study was to investigate the movement-fitness according to the surface changing of lower limb The experimental items were divided into the lower limb movements (5) and body-shapes (7). This study was done by the expansion and contraction rate consideration of length, girth Also, the lower half of body shape-change on the movements and body-shapes by flat shell was done simultaneously. The summarized findings resulted from experiments and investigation are suggested as follows; First, when commpared the expansion and contraction rate of the length and girth items, the expansion rate of the back crotch length (14~20%), hip girth (10~ 21%) and knee girth (6.2~18.5%) in rabbit leap movement was the most notable among all variables considered in this experimentation. On the others hand, the front croth length (-22~-52%) contracted remarkably. And big-thigh type was the most notable on the body-shape comparision. Second, in comparision of the expansion and contraction rate of the area on the blocks, the expansion of the hip (50~200%) and knee (51~74%) block was the most remarkable. Especially, in the sit on knees movement of the hip-down type expanded 209.4%. Third, in comparision of the lower half of body shape-change, on the movements and body- shapes by the flat shell, under the influence of knee-joint and hip-joint the shape-changs of the hip and knee block was the most notable. But the shape-change of the waist, abdomen, calf, and ankle was feeble.

  • PDF

A Study on the Characteristics of the Treatment with Bed Expansion and the Biomass Attachment in the Start-up of the AFBR (혐기성 유동층 반응기에서 층팽창에 따른 처리특성 및 미생물 부착특성)

  • 안재동;정종식;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.20-26
    • /
    • 1995
  • The objective of this study is to estimate the effect of the bed expansion and the characteristics of attached biomass in the start-up in the anaerobic fluidized bed reactor(AFBR). The fluidized bed reactor was operated with bacteria supported on the bed of granular activated carbon(GAC). The reactor was operated at 35$\circ$C, 5 kg $COD/m^3\cdot day$ at bed expansion varying from 0 to 100% with soluble glucose wastewater(5,000 mg/l). When the effluent reached a steady state at 100% of bed expansion, maximum COD removal efficiency of 87.3% and 0.031 $m^3CH_4/kg COD_{removed}$ were obtained. At higher bed expansion, COD removal efficiency, methane production rate and biogas production rate increased. Especially, at 50% of bed expansion, the efficiency of the treatment increasedg rapidly in the AFBR. The biomass colonized in the pits and crevices of the GAC particle and no complete biofilm was established in the bioreactor during the experiment.

  • PDF

Optimization of Heat Pump Systems (열펌프의 성능 최적화에 관한 연구)

  • Choi, Jong-Min;Yun, Rin;Kim, Yong-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.22-30
    • /
    • 2007
  • An expansion device plays an important role in optimizing the heat pumps by controlling refrigerant flow and balancing the system pressures. Conventional expansion devices are being gradually replaced with electronic expansion valves due to increasing focus on comfort, energy conservation, and application of a variable speed compressor. In addition, the amount of refrigerant charge in a heat pump is another primary parameter influencing system performance. In this study, the flow characteristics of the expansion devices are analyzed, and the effects of refrigerant charge amount on the performance of the heat pump and the variation of compressor speed are investigated at various operating conditions. Mass flow rate through capillary tube, short tube orifice, and EEV was strongly dependent on the upstream pressure and subcooling. The heat pump system is very sensitive with a variation of refrigerant charge amount. The performance of it can be optimized by adjusting the flow rate through expansion device to maintain a constant superheat at all test conditions.

  • PDF

The Interaction of Vortex and Premixed Flame with Consideration of Volume Expansion Effect (체적팽창효과를 고려한 예혼합화염과 와동의 상호작용에 관한 연구)

  • Chung, Eui-Heon;Kwon, Se-jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1669-1680
    • /
    • 1998
  • A method is developed to include the effect of volume expansion in the description of the flame dynamics using G-equation. Line volume-source is used to represent the effect of the exothermic process of combustion with source strength assigned by the density difference between the burned and the unburned region. The present model provides good agreement with the experimental results. Including volume expansion, the flow field is adjusted to accommodate the increased volume flow rate which crossing the flame front and the result predicts the same behavior of measured velocity field qualitatively. The effect of increasing volume expansion does not change the initial growth rate of flame area but increase the residence time. Consequently this effect increases the maximum area of flame front. The flame propagation in varying flow field due to volume expansion provides a promising way to represent the wrinkled turbulent premixed flames in a numerically efficient manner.