Browse > Article
http://dx.doi.org/10.13000/JFMSE.2013.25.2.301

Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants  

Roh, Geun-Sang (Tongmyong University)
Kim, Jong-Ryeol (Tongmyong University)
Publication Information
Journal of Fisheries and Marine Sciences Education / v.25, no.2, 2013 , pp. 301-306 More about this Journal
Abstract
In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.
Keywords
COP; Natural Refrigerant; Two-stage Compression; Two-stage Expansion;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Chaichana, C.. Aye, L. & Charters, W. W. S.(2003). Natural working fluids for solar-boosted heat pumps. Int. J. Refrigeration Vol. 26, 637-643.   DOI   ScienceOn
2 fChart Software Inc(2006). Engineering Equation Solver
3 LIM, Tae-Woo. YOU, Sam-Sang & KIM, Hwan-sung(2008), Nucleate Boiling Heat Transfer from Micor Finned Surfaces with subcooled FC-72, Jour. fish. Mar. Sci. Edu, Vol. 20, No. 3, 410-415.
4 Roh, Geon-sang(2010). Prediction on performance of Cascade Refrigeration System using Natural Refrigerants, Jour.of Korean Soc. of Mechanical Technology, Vol. 12, No. 3, 45-51.   과학기술학회마을   DOI   ScienceOn
5 Roh, Geo-nsang(2011). Prediction on performance of Cascade Refrigeration System using alternative freon Refrigerants, Jour.of Korean Soc. of Mechanical Technology, Vol. 13, No. 1, 73-79
6 UNEP(1992). Copenhagen, Decision, The Fourth Meeting of the Parties to the Montreal Protocol
7 YOU, Sam-Sang.LIM, Tae-Woo.JEONG, Seok-Kwon & PARK, Jong-Un(2007), A Study on gem microcooling Fing Fabrication Process for Enhancing Boiling Heat Transfer, Jour. fish. Mar. Sci. Edu, Vol. 19, No. 3, 366-372