• Title/Summary/Keyword: Expanded metal

Search Result 115, Processing Time 0.034 seconds

Effects of Monsoon Rainfalls on Surface Water Quality in a Mountainous Watershed under Mixed Land Use (토지이용이 다변화된 산림 유역의 수질에 미치는 몬순 강우의 영향)

  • Jo, Kyeong-Won;Lee, Hyun-Ju;Park, Ji-Hyung;Owen, Jeffrey S.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.3
    • /
    • pp.197-206
    • /
    • 2010
  • To provide baseline information essential for assessing environmental impacts of monsoon rainfalls in a mountainous watershed under mixed land use, we investigated spatiotemporal variations in water quality using a combined approach of seasonal water quality survey and intensive storm samplings. Biannual water sampling at nine locations encompassing major land use types showed generally lower electrical conductivity and Cl- concentrations during the typical wet period compared to the dry period, indicating rainfall-induced dilution of dissolved ions. Total metal concentrations, however, were significantly higher during the monsoon period, probably associated with rainfall-induced increases in suspended sediments. Intensive storm sampling during a small monsoon rainfall event (18 mm) and an extreme event (452 mm) showed rapid changes in both suspended sediments and dissolved solutes in an agricultural stream draining the Haean Basin where arable lands have expanded rapidly over the recent decades. By contrast, a nearby forest stream derived from North Korea showed little responses to the small event compared to larges changes during the extreme event. In the agricultural stream total Pb concentrations showed significant positive relationships with suspended sediments. Although limited sampling frequency and locations require a cautious interpretation, the overall results suggest that expansion of agricultural fields in steep mountainous watersheds can increase the susceptibility of soil erosion and its off-site environmental impacts under increasing rainfall variability and extremes.

Flotation for Recycling of a Waste Water Filtered from Molybdenite Tailings (몰리브덴 선광광미 응집여과액 재활용을 위한 부유선별 특성)

  • Park, Chul-Hyun;Jeon, Ho-Seok;Han, Oh-Hyung;Kim, Byoung-Gon;Baek, Sang-Ho;Kim, Hak-Sun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.235-242
    • /
    • 2010
  • Froth flotation using the residual water in the end of flotation process has been performed through controlling of pH. IEP (isoelectric point) of molybdenite and quartz in distilled water was below pH 3 and pH 2.7, respectively and the stabilized range was pH 5~10. In case of a suspension in reusing water, zeta potential of molybdenite decreased to below -10 mV or less at over pH 4 due to residual flocculants. As result of pH control, flotation efficiency in the alkaline conditions was deteriorated by flocculation, resulting from expanded polymer chain, ion bridge of the divalent metal cations ($Ca^{2+}$), and hydrophobic interactions between the nonpolar site of polymer/the hydrophobic areas of the particle surfaces. However, the weak acid conditions (pH 5.5~6) improved the efficiency of flotation as hydrogen ions neutralize polymer chains and then weakened its function. In cleans after rougher flotation, the Mo grade of 52.7% and recovery of 90.1% could be successfully obtained under the conditions of 20 g/t kerosene, 50 g/t AF65, 300 g/t $Na_2SiO_3$, pH 5.5 and 2 cleaning times. Hence, we developed a technique which can continuously supply waste water filtered from tailings into the grinding-rougher-cleaning processes.

2020 Korean Dietary Reference Intakes of selenium and a review of selenium database of foods by evaluating of selenium contents of the recommended menus (셀레늄의 2020 한국인 영양소 섭취기준 개정 및 권장식단의 셀레늄 함량 평가를 통한 식품의 셀레늄 데이터베이스 검토)

  • Choi, Kyungsuk;Lee, Okhee
    • Journal of Nutrition and Health
    • /
    • v.55 no.4
    • /
    • pp.430-440
    • /
    • 2022
  • Selenium is an important trace mineral that plays an essential role in maintaining the body's immunity with oxidative stress defense and antioxidant activity, immunity, thyroid hormone control, defense against drug or heavy metal harm, and reducing the risk of chronic diseases. A selenium deficiency increases the risk of various chronic diseases, such as cancer, cardiovascular disease, diabetes, neurological disease, osteoarthritis, muscle necrosis and weakness, thyroid disease, and inflammatory diseases. This paper explains the criteria for establishing and revising selenium in the 2020 Dietary Reference Intake for Koreans (KDRIs) and reviews the current status of the selenium database and suggestions for setting the 2025 KDRIs in the future. In the 2020 KDRIs, the selenium intake with the maximum plasma selenoprotein P level was used as the criteria. The weight and coefficient of the variation were applied to the Chinese' reported values. Compared to 2015 KDRIs, there were some revisions in the selenium dietary reference intakes by gender and age according to the change in reference weight. To improve and revise selenium dietary reference intakes in the future, a selenium intervention study is needed to determine the maximum level of plasma selenoprotein P in Koreans. In addition, a revision of the selenium database of the nutritional assessment program (CAN-Pro 5.0) is needed. An analysis of the selenium content of foods should be expanded to assess the selenium intake accurately. In addition, research on the relationship between selenium intake and the biological indicators in the body is required for healthy people and subjects of special environments, such as patients and athletes with various oxidative stress.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Risk Assessment of Heavy Metals Migrated from Plastic Food Utensils, Containers, and Packaging Distributed in Korea (국내 유통 식품용 플라스틱 기구 및 용기, 포장의 중금속 위해도 평가)

  • Kyung Youn, Lee;Hyung Soo, Kim;Dae Yong, Jang;Ye Ji, Koo;Seung Ha, Lee;Hye Bin, Yeo;Ji Su, Yoon;Kyung-Min, Lim;Jaeyun, Choi
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.175-182
    • /
    • 2022
  • Heavy metals can be intentionally or unintentionally introduced into plastic food utensils, containers, and packaging (PFUCP) as additives or contaminants, which can be ingested with food by humans. Here, seven-heavy metals (lead, cadmium, nickel, chromium, antimony, copper, and manganese) with toxicity concerns were selected, and risk assessment was done by establishing their migration from 137 PFUCP products made of 16 materials distributed in Korea. Migration of heavy metals was examined by applying 4% acetic acid as a food simulant (70℃, 30 minutes) to the PFUCP products. Inductively coupled plasma mass spectrometry (ICP-MS) was employed for the analysis of migrated heavy metals, and the reliability of quantitative results was confirmed by checking linearity, LOD, LOQ, recovery, precision, and expanded uncertainty. As a result of monitoring, heavy metals were detected at a level of non-detection to 8.76 ± 11.87 ㎍/L and most of the heavy metals investigated were only detected at trace amounts of less than 1 ㎍/L on average. However, antimony migrated from PET products was significantly higher than other groups. Risk assessment revealed that all the heavy metals investigated were safe with a margin of exposure above 311. Collectively, we demonstrated that heavy metals migrated from PFUCP products distributed in Korea appear to be within the safe range.