• Title/Summary/Keyword: Exit system

Search Result 706, Processing Time 0.032 seconds

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

Development of Expert System for Burr Formation Prediction in Face Milling (II) - In Milling Multi Featured workpiece with Multi (밀링가공시 버 형성 예측을 위한 전문가 시스템 개발 (II) - 복잡한 형상의 피삭재와 다중경로에 의한 밀링가공시)

  • 고성림;김영진;장재은;이장범;김지환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.25-33
    • /
    • 2003
  • A burr has been defined as undesirable projection of material formed as a result of plastic flow from a cutting or shearing operation. It is unavoidable in all kinds of machining operation. As a result, burr makes troubles on manufacturing process due to deburring cost, quality of products and productivity. In this study, the primary interest is about exit burr. The burr formation mechanism in each type of burr is classified. Data bases are developed to predict burr formation result. In the milling operation, we develop an algorithm to analyze the burr formation mechanism by the geometrical analysis on the multi featured workpiece with multi cutting path. The algorithm includes three steps, i. e., the feature identification, the cutting condition identification, and the analysis on exit burr formation. We can predict which portion of workpiece would have the exit burr in advance so that we can manage to find a way to minimize the exit burr formation in an actual cutting. Also, this algorithm can be implemented in a commercial CAM package so that we can simulate the NC code to review the burr formation in advance.

Design of Low-Density Parity-Check Codes for Multiple-Input Multiple-Output Systems (Multiple-Input Multiple-output system을 위한 Low-Density Parity-Check codes 설계)

  • Shin, Jeong-Hwan;Chae, Hyun-Do;Han, In-Duk;Heo, Jun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.587-593
    • /
    • 2010
  • In this paper we design an irregular low-density parity-check (LDPC) code for multiple-input multiple-output (MIMO) system, using a simple extrinsic information transfer (EXIT) chart method. The MIMO systems considered are optimal maximum a posteriori probability (MAP) detector. The MIMO detector and the LDPC decoder exchange soft information and form a turbo iterative receiver. The EXIT charts are used to obtain the edge degree distribution of the irregular LDPC code which is optimized for the MIMO detector. It is shown that the performance of the designed LDPC code is better than that of conventional LDPC code which was optimized for either the Additive White Gaussian Noise (AWGN) channel or the MIMO channel.

Analysis of Flow Around A Rigid Body on Water-Entry & Exit Problems (접수와 이수 문제에서 강체주위 유동해석)

  • Il-Ryong Park;Ho-Hwan Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.37-47
    • /
    • 1999
  • A Finite Volume Method for the discretization of the two-dimensional incompressible Navier-Stokes equation is used to analyse water entry & exit problems in a generalized coordinate system. The free-surface deformations generated by the water entry or exit of a rigid body are simulated by the Level-Set scheme[11]. In the water entry problems for a wedged section and a flared-ship section, the calculation results of water impact force are compared with the experimental results[5] and the time varying free-surface deformations and flow characteristics of the water exit of a cylinder are investigated.

  • PDF

A Study on Burial Guideline of Horizontal Geothermal Heat Exchanger based on Exit Temperature (출구 온도를 고려한 수평형 지중열교환기의 매설 지침에 관한 연구)

  • Cho, Sung-Woo;Ihm, Pyeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.553-558
    • /
    • 2014
  • Geothermal energy can be used with a geothermal heat pump or an earth-to-air heat exchange system (EAHES), which is referred to as a "cooling tube" in Korea. In this study, we suggest EAHES burial guidelines in terms of the parameters of buried pipe length and air velocity regarding the exit air temperature of EAHES. The exit air temperature for EAHES in three regions (Changwon, Busan and Seoul) was calculated with variation in buried pipe length and air velocity at ${\Phi}100mm$ and ${\Phi}200mm$. In conclusion, variation in the buried pipe length is more effective than that of air velocity to achieve the required exit air temperature.

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.

Route Exploration Algorithm for Emergency Rescue Support on Urgent Disaster (긴급 재해 발생 시 피난 지원을 위한 탈출 경로 탐색 알고리즘)

  • Hwang, Jun-Su;Choi, Young-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.12-21
    • /
    • 2016
  • The emergency evacuation support system supports evacuation assistance when an urgent disaster occurs. We have implemented evacuation route search algorithm to assist people's escape when a disaster occurs such as fires or terrorism in the building. The algorithm will guide the escape route at the fastest emergency exit of each region at the emergency state. The algorithm calculates the escape route by applying the weighting factor of age groups and population density around the emergency exit and of other regions. So the system helps escape to bypass the crowded emergency exit and the disaster area, and reduces the congestion of emergency exit and overloading of evacuation route.

Computer Simulation Study of the Thermoelectric Cooling by Hybrid Method (하이브리드법을 이용한 열전냉각의 수치해석 연구)

  • Kim, N.J.;Lee, J.Y.;Kim, C.B.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.97-108
    • /
    • 2000
  • The purpose of this study is to minimize the heat transfer surface area and cold fluid exit temperature of heat exchanger which applied to the refrigeration and air-conditioning system by utilizing the thermoelectric principle. Both uniform and non-uniform current distribution methods which applied to the analysis of the TE elements that incorporates heat exchanger were investigated. The non-uniform current distribution method had the better coefficient of performance and had the lower cold fluid exit temperature of the TE cooling system than the uniform current distribution method. It was found that if a TE cooling system incorporates a heat exchanger, a non-uniform current distribution should guarantee to the lowest cold fluid exit temperature. Also, the hybrid method (combination of the uniform and non-uniform current distribution method) is investigated to achieve the best results by combining the uniform and non-uniform current distributions. The results show that it can lower the cold fluid exit temperature and reduce the heat transfer surface area for the parallel flow arrangement if we apply the constant current in some entry region and the non-uniform increasing current in the direction of the cold fluid flow afterwards.

  • PDF

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

A study on the Improvement Method of the Report and Reward System on an Illegal Behavior of the Emergency Exit (비상구 불법행위 신고포상제도의 개선방안에 관한 연구)

  • Kim, Myeong Sik;Lee, Tae Shik;Cho, Won Cheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.49-59
    • /
    • 2012
  • The safety management of the emergency exit, by directly related to the $civil^{\circ}$Øs dead in the fire situation, have limited by which the fire station take the on-side and control-centered way of business processing, it is expect to the effects in which the citizen have to concern and to take part. From 2010 years in the back-ground, it is operated nationally the report and reward system on an illegal behavior of the emergency exit, it is happened to the unfit operating situation in the mission and direction of the system up which the exit paparazzi act with intent to receive the reward payments. The study suggests solution through analyzing the illegal emergency exit operation result of sixteen counties and the Seoul metropolitan from year 2010 to 2011. Firstly, the report destination is adjusted to the multiple use establishments and the large-scale multiple use facilities over the limit level is limited under five times the report events of the same people in the minor endorsement. And the fine incomes should be invested to the disaster prevention acting related with the exit. Secondly, for upgrade of the report accuracy, a reporter is received the possible information for the confirmation of an illegal act, has become to lead the pre-monitoring act which the reporter is can to take the safety education and to guide the information about season and vulnerable business location. Finally, considering the support way about the encounter facility, the fire officer is not happen to occur the repetitive report in the same place, is related to the volunteer service system the report acts, consider as the volunteer service time, and must support them to act as the disaster prevention volunteer.