• 제목/요약/키워드: Exhaust gas heat exchanger

검색결과 92건 처리시간 0.034초

3 MWth 급 매체순환연소 시스템의 운전변수 변화에 따른 성능 예측 (Performance Prediction of 3 MWth Chemical Looping Combustion System with Change of Operating Variables)

  • 류호정;남형석;황병욱;김하나;원유섭;김대욱;김동원;이규화;전명훈;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.419-429
    • /
    • 2022
  • Effects of operating variables on temperature profile and performance of 3 MWth chemical looping combustion system were estimated by mass and energy balance analysis based on configuration and dimension of the system determined by design tool. Air reactor gas velocity, fuel reactor gas velocity, solid circulation rate, and solid input percentage to fluidized bed heat exchanger were considered as representative operating variables. Overall heat output and oxygen concentration in the exhaust gas from the air reactor increased but temperature difference decreased as air reactor gas velocity increased. Overall heat output, required solid circulation rate, and temperature difference increased as fuel reactor gas velocity increased. However, overall heat output and temperature difference decreased as solid circulation rate increased. Temperature difference decreased as solid circulation rate through the fluidized bed heat exchanger increased. Effect of each variables on temperature profile and performance can be determined and these results will be helpful to determine operating range of each variable.

열교환 단일 원관의 양력과 항력 변동에 따른 PSD 특성 연구 (The Power Spectral Density Characteristics of Lift and Drag Fluctuation on a Heat Exchanger Circular Tube)

  • 하지수
    • 한국가스학회지
    • /
    • 제19권4호
    • /
    • pp.35-40
    • /
    • 2015
  • 열교환기의 전열관군은 전열관군 외부로 흐르는 유동에 의해 유동 유발 진동이 일어나며 이것으로 말미암아 전열관군에서 파손을 야기할 수 있어서 열교환기의 구조적 안정성을 위해 열교환기의 전열관군에서 유동 유발 진동 특성을 규명할 필요가 있다. 일반적인 열교환기 전열관군에서 유동 유발 진동에 관한 실험적 연구는 기존에 많이 진행되어 오고 있으며 유동 유발 진동에 대한 무차원 PSD(Power Spectral Density) 함수를 무차원 주파수인 Strouhal 수, fU/U의 함수로 도출된 실험적 결과들이 도출되어 있다. 본 연구는 열교환기 단일 원관에서 유동 유발 진동에 관한 기존의 연구들의 결과를 전산유체해석을 통해 검증하고 배열회수 보일러의 전열관군의 유동 유발 진동 특성에 적용하기 위한 기반을 마련하는 것을 목적으로 한다. 이러한 것을 위해 단일 원관에서 비정상 상태 유동해석을 수행하여 주기적인 와동 발생 특성과 원관에서의 양력과 항력의 변화 특성을 살펴보았다. 또한 원관에서 양력과 항력의 변동 특성으로부터 유동 유발 진동에 따른 PSD 특성 결과를 도출하여 기존의 연구들과 비교를 통해 원관 주위의 PSD 특성을 살펴보았으며 양력과 항력의 진폭과 주파수의 특성을 규명하였다.

순산소 재순환 연소를 채택한 $CO_2$ 회수형 보일러 개발: 3 MW급 시스템 연소 특성 (Oxy-fuel FGR Combustion Boiler for $CO_2$ Capturing: 3 MW Class Combustion Experiment)

  • 안준;김혁주;최규성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1019-1024
    • /
    • 2008
  • A 3 MW class oxy-fuel boiler has been developed to capture $CO_2$ from the exhaust gas. The system is a scale-up of the previous 0.5 MW class system in general. A heat exchanger and a mixer are additionally installed to stabilize the flame for the FGR mode. The system yields the exhaust gas with $CO_2$ concentration over 90% and reduced NO emission to 1/10 of conventional air combustion system.

  • PDF

배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구 (The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator)

  • 하지수;이부윤
    • 한국가스학회지
    • /
    • 제20권2호
    • /
    • pp.23-29
    • /
    • 2016
  • 배열회수 보일러의 전열관군은 외부에 고온의 배기가스가 흐르면서 유동 유발 진동을 야기 시키며 배열회수 보일러의 전열관군에서 파손을 야기할 수 있어서 열교환기의 구조적 안정성을 위해 열교환기의 전열관군에서 유동 유발 진동 특성을 규명할 필요가 있다. 일반적인 열교환기 전열관군에서 유동 유발 진동에 관한 실험적 연구는 기존에 많이 진행되어 오고 있으며 단일 원관이나 전열관군의 원관들에서 유동 유발 진동에 대한 무차원 PSD(Power Spectral Density) 함수를 무차원 주파수인 Strouhal 수, fD/U의 함수로 도출된 실험적 결과들이 도출되어 있다. 본 연구는 배열회수 보일러에 사용하는 휜튜브 전열관군에서 유동 유발 진동 특성을 규명하는 것을 목적으로 한다. 이러한 것을 위해 단일 휜튜브에서 비정상 상태 유동해석을 수행하여 주기적인 와동 발생 특성과 단일 휜튜브에서의 양력과 항력 변화 특성을 살펴보았다. 또한 단일 휜튜브에서 양력과 항력 변동 특성으로부터 유동 유발 진동에 따른 PSD 특성 결과를 도출하여 기존에 단순 원관에서 이루어졌던 연구들과 비교를 통해 단일 휜튜브 주위의 PSD 특성을 정립하였다.

Numerical and experimental studies of cryogenic reciprocating expander without inner piston

  • Park, Sehyeon;Bae, Junhyuk;Kim, Kyoungjoong;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권3호
    • /
    • pp.21-27
    • /
    • 2018
  • It is difficult to fabricate and maintain moving parts of expander at cryogenic temperature. This paper describes numerical analysis and experimental investigation on a cryogenic reciprocating expander without moving piston. An intake valve which takes high-pressure gas, and an exhaust valve which discharges low-pressure gas, are connected to a tube. The inside pressure of the tube is pulsated for work production. This geometric configuration is similar to that of pulse tube refrigerator but without regenerator. An orifice valve and a reservoir are installed to control the phase of the mass flow and the pressure. At the warm end, a heat exchanger rejects the heat which is converted from the produced work of the expanded gas. For the numerical analysis, mass conservation, energy conservation, and local mass function for valves are used as the governing equations. Before performing cryogenic experiments, we carried out the expander test at room temperature and compared the performance results with the numerical results. For cryogenic experiments, the gas is pre-cooled by liquid nitrogen, and then it enters the pulse tube expander. The experiments are controlled by the opening of the orifice valve. Numerical analysis also found the expander conditions that optimize the expander performance by changing the intake pressure and valve timing as well as the opening of the orifice valve. This paper discusses the experimental data and the numerical analysis results to understand the fundamental behavior of such a newly developed non-mechanical expander and elucidate its potential feature for cryogenic application.

대형 가솔린 엔진의 폐열 회수 장치인 슈퍼히터의 최적 위치선정을 위한 시뮬레이션 연구 (A Simulation Study for Selecting Optimum Position of a Superheater in a Waste Heat Recovery System Integrated with a Large Gasoline Engine)

  • 김세린;최경욱;이기형;김기범
    • 대한기계학회논문집B
    • /
    • 제40권2호
    • /
    • pp.69-73
    • /
    • 2016
  • 최근 자동차 엔지니어들은 자동차 엔진의 열효율을 향상시키기 위한 수단으로 폐열 회수 기술에 많은 관심을 기울이고 있다. 배기량이 큰 가솔린 엔진은 대체로 V형인데, 열 회수를 위해 두 개의 슈퍼히터를 각각의 배기 다기관 가까이에 설치하는 것은 비용 면에서 효율적이지 않다. 하나의 슈퍼히터를 한쪽 배기 다기관에 최대한 가깝게 부착하면 좀 더 높은 열교환 효율을 얻을 수 있으나 폐열회수를 위한 배기가스의 유량은 절반이 된다. 반면에, 배기가스의 유량을 전부 이용하기 위하여 두 배기관이 합류된 지점에 슈퍼히터를 설치하면 배기가스의 온도는 많이 감소된다. 이 사실을 바탕으로 슈퍼히터의 최적 위치를 조사하기 위하여 상용프로그램인 AMESim을 이용해 해석을 수행하였다. 이 때, 배기가스 유량 중 절반만을 사용하더라도 슈퍼히터를 배기 다기관과 최대한 가까이 부착하는 것이 엔진의 배기가스로부터 3.8 kW의 열을 더 회수할 수 있는 것으로 나타났다. 이 결과를 바탕으로 최적의 폐열 회수 모델을 도출하고 제안하였다.

수직 Rayleigh 유동내의 입자 거동 해석 (Analysis of Particles Motion in Vertical Rayleigh Flow)

  • 고석보;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.447-456
    • /
    • 2007
  • Suspended particles behavior when they go through a vertical riser with heat transfer is of significant concern to system designers and operators in pneumatic transport, various processes such as in chemical, pharmaceutical and food industries. When it comes with the energy system, that knowledge is critical to the reliable design practices of related equipment as heat exchangers, especially in the phase of system scale-up. Without haying a good understanding of the related physics, many scale-up practices based on their pilot plant experience suffer from unexpected behaviors and problems of unstable fluidization typically associated with excessive pressure drop, pressure fluctuation and even unsuccessful particle circulation. In the present study, we try to explain the observed phenomena with related physics, which may help understanding of our unanswered experiences and to provide the designers with more reliable resources for their work. We selected hot exhaust gas with solid particle that goes through a heat exchanger riser as our model to be considered. The effect of temperature change on the gas velocity, thermodynamic properties, and eventually on the particles motion behavior is reviewed along with some heat transfer analyses. The present study presents an optimal riser length at full scale under given conditions, and also defines the theoretical limiting length of the riser. The field data from the numerical analysis was validated against our experimental results.

상변화물질(PCM)을 이용한 가정용 보일러의 잠열축열식 예열모듈 개발 (Development of Preheating Module for Domestic Heating Facility, Using PCM(Phase Change Material) Thermal Storage Equipment)

  • 손철민;김태욱;나규동
    • 한국산업융합학회 논문집
    • /
    • 제12권3호
    • /
    • pp.163-169
    • /
    • 2009
  • A preheating module for domestic heating facility will increase a energy efficiency. That collects the wasted heat of exhaust gas and saves the energy. So a heating load is decreased because of a preheating that has a heating energy. Using of a preheating module, a boiler can reduce frequent operation of a burner. So it is increased persistence, decreased discharging noxious gases. Therefore we will intend to develop a heating facility that is a convenient system for the saving energy.

  • PDF

열교환 단일 원관의 유동 유발 진동 특성에 관한 연구 (A study on the flow induced vibration on a heat exchanger circular cylinder)

  • 하지수;이부윤;심성훈
    • 에너지공학
    • /
    • 제24권3호
    • /
    • pp.109-114
    • /
    • 2015
  • 배열회수 보일러의 전열관군은 외부에 고온의 배기가스가 흐르면서 유동 유발 진동을 야기 시키며 배열회수 보일러의 전열관군에서 파손을 야기할 수 있어서 열교환기의 구조적 안정성을 위해 열교환기의 전열관군에서 유동 유발 진동 특성을 규명할 필요가 있다. 일반적인 열교환기 전열관군에서 유동 유발 진동에 관한 실험적 연구는 기존에 많이 진행되어 오고 있으며 유동 유발 진동에 대한 무차원 PSD(Power Spectral Density) 함수를 무차원 주파수인 Strouhal 수, fU/U의 함수로 도출된 실험적 결과들이 도출되어 있다. 본 연구는 열교환기 전열관군에서 유동 유발 진동에 관한 기존의 연구들의 결과를 전산유체해석을 통해 검증하고 배열회수 보일러의 전열관군의 유동 유발 진동 특성에 적용하기 위한 기반을 마련하는 것을 목적으로 한다. 이러한 것을 위해 단일 원관에서 비정상 상태 유동해석을 수행하여 주기적인 와동 발생 특성과 원관에서의 양력 변화 특성을 살펴보았다. 또한 원관에서 양력 변동 특성으로부터 유동 유발 진동에 따른 PSD 특성 결과를 도출하여 기존의 연구들과 비교를 통해 원관 주위의 PSD 특성을 정립하였다.