• 제목/요약/키워드: Exhaust fan

검색결과 134건 처리시간 0.032초

실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구 (A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

무창돈사를 위한 컨트롤러 일체형 환기팬 개발 (Development of Exhaust Fan with an Embedded Controller for Windowless Swine Housing)

  • 김웅
    • 농업생명과학연구
    • /
    • 제50권2호
    • /
    • pp.187-194
    • /
    • 2016
  • 본 연구는 무창돈사에서 최적 환경조절이 가능한 시스템을 구축하고자 환경조절이 가능한 모형돈사를 제작하여 온도분포특성을 분석하고 ICT 융합기술을 활용한 온도센서 위치 최적화 및 컨트롤 일체형 환기팬을 개발하고자 하였다. 팬 상부에 부착된 센서에 의해 측정된 온도는 다른 측점온도보다 1℃ 내의 낮은 온도차를 나타내어 측정오차를 고려할 때 온도센서가 팬 상부에 위치하여도 문제가 없을 것으로 판단되었다. 환기팬 성능은 최대 출력일 때 회전수 1920rpm, 송풍량 125㎥/min로 나타났으며, 최대 효율은 개방면적비 약 70%를 고려할 경우 사용된 환기팬의 적정 송풍량은 75㎥/min에 60pa로 나타났다. 댐퍼의 개방면적비가 약 70%일 때 환기팬의 동력과 상관없이 최대효율을 나타내었다. 팬의 출력별 회전수는 출력 100%일 때 최대 1,920rpm으로 나타났으며, 컨트롤러의 펄스 듀티비를 변화시킴에 따라 AC 출력 위상이 지연 없이 변화하는 것으로 나타나 빠른 응답속도로 팬 속도조절이 가능한 것으로 판단되었다.

공동주택의 주방에서 사용되는 시판 환풍기의 환기 성능 평가에 관한 연구 (A Study on the Ventilation Performance Estimation of Marketing Ventilation Fan Used in the Apartment House Kitchen)

  • 송필동;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.315-320
    • /
    • 2002
  • Marketing ventilation fan 3 kinds been using in kitchen of apartment house into compensation discharge performance of contaminant measure. When propane gas burns by gas table, did waste heat into measurement compensation with carbon dioxide that it happens. In measured all type of exhaust fan, discharge performance of carbon dioxide and waste heat was high there are been much displacement. Among A, B, C three types, performance of A type exhaust fan was most superior and performance of C type exhaust fan was most poor

  • PDF

친환경 환풍기를 위한 BLDC모터 제어기 연구 (Research for Environmentally Friendly Exhaust Fan BLDC Motor Controller)

  • 정영득
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.403-410
    • /
    • 2015
  • This study documents the 3-phase BLDC(Brushless DC) motor to improve conventional exhaust fan motor. Energy efficiency, noise, and air pollution reduction for the high-performance vibration of the BLDC motor has been used in many fields. It is necessary to achieve the information of rotor position for driving 3-phase type brushless DC motor. It is also necessary that the PWM control algorithm design for a MOSFET driver to control the motor speed control for each of three phases. BLDC motors for exhaust fan, we studied the controller and software. The control circuit and motor control program through which Exhaust fan up close and person can be used safely and protect the environment.

공동주택의 국소배기용 루프팬 성능개선에 관한 연구 (Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment)

  • 권용일;정열화;안정헌
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계 (Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit)

  • 유기정;김유일;이관수;차우호
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구 (A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

초음파 수첨가 연소에 의한 석유 홴 히터의 배기가스 특성 고찰 (An Investigation of Combustion Emission Characteristics of Kerosene Fan Heater with Addition of Water Droplets by Ultrasonic Atomizer)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.44-53
    • /
    • 1999
  • This study is concerned with the emission characteristics of kerosene fan heater, which is burned with kerosene and water droplets simultaneously in the burner, in order to prohibit the emissions of harmful exhaust gas and reduce smell caused by incomplete combustion, and the addition of water droplets to the conventional kerosene fan heater was performed by ultrasonic atomizer. For the investigation of this study, the measurement of exhaust gas components and exhaust gas temperature was carried out by using an automatic combustion gas analyser and $NO_x$ analyser, and the measurement of consumption weight of oil and water was obtained by using electric digital balance. Consequently, according as the water percent weight ratio of about $21{\sim}23%$ was supplied for this study, it was found that the combustion-generated $NO_x$ and CO emissions were reduced very largely, but the emissions of $O_2\;and\;CO_2$ and the temperature of exhaust gas were not changed.

  • PDF

배연용 축류팬의 내열 신뢰성 향상 (Improvement of the Heat Resistance Reliability of an Axial Smoke Exhaust Fan)

  • 허진혁;허기무;문승재;이재헌
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.656-662
    • /
    • 2009
  • In this paper, the heat resistance reliability of an axial smoke exhaust fan was investigated. An axial smoke exhaust fan should be capable of operating at $250^{\circ}C$ for 2 hours. The heat resistance reliability was evaluated by the heat resistance reliability test. A B10 life with a 90% confidence level was estimated to be about 48 minute. The failure occurred in the motor due to high temperature. The main failure mechanisms of the motor were melting of bond and insulating paper and burning of insulating materials in the coil. The heat resistance reliability was improved by changing the way to unite the core and the coil and by replacing the insulating paper and the insulating materials of the coil. A B10 life with a 90% confidence level of a modified axial smoke exhaust fan was estimated to be over 120 minute.

가스를 연료로 사용한 주방에서의 오염물질 발생 특성에 대한 연구 (A Study on the Occurrence Character of Contaminant in the Kitchen that Use Gas Fuel)

  • 박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2001년도 학술발표대회논문집
    • /
    • pp.77-82
    • /
    • 2001
  • This paper is contents that measure the ventilation rates and temperature by driving condition of exhaust fan, vapor, contaminant occurrence amount of carbon dioxide etc. In kitchen of apartment house. The ventilation rates in the apartment kitchen measured by Tracer Gas Method. And, temperature of when cook by gas table hood lower part 10cm and floor upside 10cm of kitchen central part, 120cm, 210cm heights measure. As ventilation rates measurement result, ventilation number of times was 0.7(number of times/hour) when did not to operate exhaust fan. but we were measured by 2.3(number of times/hour) when drove strongly. As temperature measurement result at cooking by gas table, temperature showed highest in hood lower part 10cm of case that do not operate exhaust fan. Temperature at kitchen central was most low in 10cm height in talc floor, and 210cm were measured highest. Concentration of carbon dioxide is very high by 4,350ppm after measurement time 10 minutes in state who do not operate exhaust fan at cooking by gas table.

  • PDF