• Title/Summary/Keyword: Excitation circuit

Search Result 146, Processing Time 0.026 seconds

Design of Permanent Magnet Type Wind Power Generators for Cogging Torque Reduction with Optimum Pole Arc Pitch Ratio (코깅토크 저감을 위한 최적 극호비를 갖는 영구자석형 풍력발전기의 설계)

  • Jang, Seok-Myeong;Kim, Jin-Soon;Ko, Kyoung-Jin;Choi, Jang-Young;Yoon, Gi-Gab
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.38-40
    • /
    • 2009
  • In order to achieve a gearless construction of the wind energy conversion system(WECS), a low-speed generator should be used. Of the various candidate machine types, radial-field, multi-pole, permanent magnet, synchronous machines may be used for low-speed applications. So, this paper deals with the design of direct-coupled, multi-pole radial field machines with permanent magnet(PM) excitation for wind power applications for cogging torque reduction through the determination of optimum pole arc/pitch ratio. On the basis of an equivalent magnetic circuit method(EMCM) and a space harmonic method(SHM), an initial design is performed considering restricted conditions. And then, a detailed design is made using a non-linear finite element analyses(FEA). Finally, test results concerning generating characteristics are given to confirm the validation of the design.

  • PDF

Tandem Structured Hot Electron-based Photovoltaic Cell with Double Schottky Barriers

  • Lee, Young Keun;Lee, Hyosun;Park, Jeong Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.310.1-310.1
    • /
    • 2013
  • We show the novel hot electron based-solar energy conversion using tandem structured Schottky diode with double Schottky barriers. In this report, we show the effect of the double Schottky barriers on solar cell performance by enhancing both of internal photoemission and band-to-band excitation. The tandem structured Au/Si diode capped with TiO2 layer as second semiconductor exhibited improved ability for light harvesting. The proposed mechanisms consist of multiple reflections of hot electrons and additional pathway of solar energy conversion due to presence of multiple interfaces between thin gold film and semiconductors. Short-circuit photocurrent measured on the tandem structured Au/Si diodes under illumination of AM1.5 increased by approximately 70% from 3.1% to 5.3% and overall incident photon to electron conversion efficiency (IPCE) was enhanced in visible light, revealing that the concept of the double Schottky barriers have significant potential as novel strategy for light harvesting.

  • PDF

Morus Nigra Extract Attenuates Cognition Impairment and GABAergic Interneuron Degeneration in Aged Rat Brain

  • Lee, Joo Hee;Kim, Yoonju;Song, Min Kyung;Kim, Youn-Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.24 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • Purpose: Aging process comes with cognitive impairment due to decreased neuronal cell number, activity, and neuronal circuit. Alteration of inhibitory neurons contributes to cognitive impairment in normal aging and is responsible for disrupting the excitation/inhibition balance by reducing the synthesis of gamma-aminobutyric acid (GABA). Morus nigra (Mulberry) is a natural physiologically active substance that has been proven to have anti-oxidant, anti-diabetic, and anti-inflammatory effects through many studies. This study aimed to evaluate the effects of the mulberry extract (ME) on cognitive function through anti-oxidant enzyme and GABAergic neuronal activity in aged rat brain. Methods: Sprague Dawley rats were randomly assigned as the young group (8 weeks, n= 8), aging group (67 weeks, n= 8), and aging+ mulberry extract group (67 weeks, n= 8). The aging+ mulberry extract group was orally administered 500 mg/kg/d mulberry extract for 6 weeks. Results: The aging+ mulberry extract group improved spatial and short-term memory. The antioxidant potential of ME increased the expression of superoxide dismutase-1 (SOD-1) and decreased inducible nitric oxide synthase (iNOS). Also, the aging+ mulberry extract group significantly increased the expression of GABAergic interneuron in hippocampus cornu ammonis1 (CA1) compared to the aging group. Conclusion: The number of GABAergic inhibitory interneurons was deceased and memory functions in the aging process, but those symptoms were improved and restored by mulberry extract administration.

Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger (전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가)

  • Kang, Hyung-Sub;Hong, Young-Pyo;Lee, In-Ho;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.558-566
    • /
    • 2017
  • In this study, we developed an electron-emission OH radical generator for waste water treatment. The stability of the circuitry was ensured by implementing stable pulse waves with a MOSFET and reducing the momentary current rise. The OH radical generator uses a high-voltage and low-current discharger. The performance of the device was evaluated experimentally, which showed that it is possible to produce a stable and uniform pulse waveform for the drain current of the power MOSFET, which is connected to the input side of an AC multiplying converter through negative feedback circuitry with CR-snubber architecture. It was also possible to reduce the excitation current of the converter and improve the stability of the oscillation circuit. In addition, the generator can generate hydroxyl radicals stably. The bactericidal activities were also evaluated, and the germicidal power for E. coli, S. aureus, and S. flexneriwas improved by 99.9% or more after 60 minutes.

Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator (스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

Effect of Sintering Temperature on Dielectric Properties of 72 wt%(Al2O3):28 wt%(SiO2) Ceramics

  • Sahu, Manisha;Panigrahi, Basanta Kumar;Kim, Hoe Joon;Deepti, PL;Hajra, Sugato;Mohanta, Kalyani
    • Korean Journal of Materials Research
    • /
    • v.30 no.10
    • /
    • pp.495-501
    • /
    • 2020
  • The various sintered samples comprising of 72 wt% (Al2O3) : 28 wt% (SiO2) based ceramics were fabricated using a colloidal processing route. The phase analysis of the ceramics was performed using an X-ray diffractometer (XRD) at room temperature confirming the presence of Al2O5Si and Al5.33Si0.67O9.33. The surface morphology of the fracture surface of the different sintered samples having different sizes of grain distribution. The resistive and capacitive properties of the three different sintered samples at frequency sweep (1 kHz to 1 MHz). The contribution of grain and the non-Debye relaxation process is seen for various sintered samples in the Nyquist plot. The ferroelectric loop of the various sintered sample shows a slim shape giving rise to low remnant polarization. The excitation performance of the sample at a constant electric signal has been examined utilizing a designed electrical circuit. The above result suggests that the prepared lead-free ceramic can act as a base for designing of dielectric capacitors or resonators.

Plasma control by tuning network modification in 4MHz ionized-physical vapor deposition (4MHz I-PVD장치에서 정합회로를 이용한 플라즈마 제어)

  • 주정훈
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.75-82
    • /
    • 1999
  • Ion energy is one of the crucial property in thin film deposition by internal ICP assisted I-PVD. As ion energy is determined by the difference between the plasma potential and the substrate bias potential, ICP excitation frequency was tested with medium frequency of 4 MHz and two types of tuning circuits, alternate and floating LC network with a biasing resistor, were tested. The results showed that plasma potential was less than 5 V in a range of Ar pressures, 5mTorr to 30 mTorr, at 4 MHz RF 600 W and 60 V of maximum RF antenna voltage was maintained either at RF input or output terminal. By proper control of RLC circuit installed after after RF antenna, 50V of RF induced voltage on RF antenna was obtained at 500W input power. The total impedance of RF antenna and plasma was around 10$\Omega$, and minimum RF voltage was obtained with a condition of lowest reactance at most 0.05$\Omega$.

  • PDF

Bias-Dependent Photoluminescence Analysis on InGaN/GaN MQW Solar Cells

  • Shim, Jae-Phil;Jeong, Hoonil;Choi, Sang-Bae;Song, Young Ho;Jho, Young-Dahl;Lee, Dong-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.347-348
    • /
    • 2013
  • To obtain high conversion efficiency in InGaN-based solar cells, it is critical to grow high indium (In) composed InGaN layer for increasing sun light absorption wavelength rage. At present, most InGaN-based solar cells adopt InGaN/GaN multi-quantum-well (MQW) structure for high crystalline quality of InGaN with high In composition. In this study, we fabricated and compared the performances of two types of InGaN/GaN MQW solar cells which have the 15% (SC 15) and 25% (SC 25) of In composition at quantum well layer. Although both devices showed similar dark current density and leakage current, SC 15 showed better performance under AM 1.5G illumination as shown in Fig. 1. It is interesting to note that SC 25 showed severe current density decrease as increasing voltages. As a result, it lowered short circuit current density and fill factor of the device. However, SC 15 showed steady current density and over 75 % of fill factor. To investigate these differencesmore clearly, we analyzed their photoluminescence (PL) spectra under various applied voltages as shown in Fig. 2. At the same time, photocurrent, which was generated by PL excitation, was also measured as shown in Fig. 3. Further, we investigated the relationship between piezoelectric field and performance of InGaN based solar cell varying indium composition.

  • PDF

Analytical evaluation and experimental validation of energy harvesting using low-frequency band of piezoelectric bimorph actuator

  • Mishra, Kaushik;Panda, Subrata K.;Kumar, Vikash;Dewangan, Hukum Chand
    • Smart Structures and Systems
    • /
    • v.26 no.3
    • /
    • pp.391-401
    • /
    • 2020
  • The present article reports the feasibility of the electrical energy generation from ambient low-frequency vibration using a piezoelectric material mounted on a bimorph cantilever beam actuator. A corresponding higher-order analytical model is developed using MATLAB in conjunction with finite element method under low-frequency with both damped and undamped conditions. An alternate model is also developed to check the material and dimensional viability of both piezoelectric materials (mainly focussed to PVDF and PZT) and the base material. Also, Genetic Algorithm is implemented to find the optimum dimensions which can produce the higher values of voltage at low-frequency frequencies (≤ 100 Hz). The delamination constraints are employed to avoid inter-laminar stresses and to increase the fracture toughness. The delamination has been done using a Teflon sheet sandwiched in between base plates and the piezo material is stuck to the base plate using adhesives. The analytical model is tested for both homogenous and isotropic material characteristics of the base material and extended to investigate the effect of the different geometrical parameters (base plate dimensions, piezo layer dimensions and placement, delamination thickness and placement, excitation frequency) on the model responses of the bimorph cantilever beam. It has been observed that when the base material characteristics are homogenous, the efficiency of the model remains higher when compared to the condition when it is of isotropic material. The necessary convergence behaviour of the current numerical model has been established and checked for the accuracy by comparing with available published results. Finally, using the results obtained from the model, a prototype is fabricated for the experimental validation via a suitable circuit considering Glass fibre and Aluminium as the bimorph material.

A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.