• Title/Summary/Keyword: Exchange flow

Search Result 827, Processing Time 0.025 seconds

Performance Characteristics of PEMFC by flow Configurations and Operating Condition (유로형상 및 운전조건에 따른 고분자 전해질 연료전지의 성능 특성)

  • Lee, Pil-Hyong;Cho, Son-Ah;Han, Sang-Seok;Hwang, Sang-Soon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3440-3445
    • /
    • 2007
  • For proton exchange membrane fuel cell, it is very important to design the flow channel on separation plate optimally to maximize the current density at same electrochemical reaction surface and reduce the concentration polarization occurred at high current density. In this paper, three dimensional computation model including anode and cathode domain together was developed to examine effects of flow patterns and operation conditions such as humidity and operating temperature on performance of fuel cell. Results show that voltage at counter flow condition is higher than that at coflow condition in parallel and interdigitated flow pattern. And fuel cell with interdigitated flow pattern which has better mass transport by convection flow through gas diffusion layer has higher performance than with parallel flow pattern but its pressure drop is increased such that the trade off between performance and pressure drop should be considered for selection of flow pattern of fuel cell.

  • PDF

High Efficiency Hybrid Ion Exchange Chemical Filter for Removal of Acidic Harmful Gases (산성유해가스 제거를 위한 고효율 음이온교환 복합 폼 화학필터의 제조)

  • Jung, Youn Seo;Kim, In Sik;Hyeon, Seung Mi;Hwang, Taek Sung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.539-546
    • /
    • 2017
  • In this study, an outstanding anion exchange chemical filter was prepared for acidic gas removal. Commercial anion exchange resin was attached to polyurethane (PU) foam by using different types of pressure sensitive adhesive (PSA). The water and chemical resistance and also adhesive elongation were investigated. Also, the behavior of HCl and HF adsorption was evaluated as functions of the initial concentration and flow rate. ATE-701, AT-4000C and HCA-1000 showed 900, 1,500% and 2,400% of the elongation, respectively. It was confirmed that the desorption ratio of HCA-1000 was less than 6% and had excellent durability in water and chemical resistance tests. The adsorption occurred faster as the concentration and flow rate of HCl and HF increased. But 100% adsorption equilibrium occurred after 110 minutes, regardless of the concentration and flow rate. In addition, SEM morphology showed that the adhesive was uniformly dispersed, while the porous structure of the ion exchange resin was maintained, and the chemical filter exhibited excellent durability for the adsorption/desorption process.

Tidal Exchange Of Sea Water In Gamag Bay (가막만의 해수교환)

  • Lee, Myeong-Cheol;Chang, Sun-duck
    • 한국해양학회지
    • /
    • v.17 no.1
    • /
    • pp.12-18
    • /
    • 1982
  • Tidal exchanges of sea water are studied by using drogue experiments and tidal current measurement data in Gamag Bay which has two channels. At the spring tide, the volume of tidal transport in the bay was estimated to be 46∼52% of the total volume of sea water in Gamag Bay, 7.1 10$\^$8/㎥. The tidal transport through the wide channel occupies 87% of the total tide transport of the bay. Residual current was deduced to flow north-northeastward at the rate of 3.254 10$\^$5/㎥ per tidal cycle. the tidal exchange of the sea water during the flood flow was estimated to be approximately 26% of the tidal transport, while that during the ebb flow was 41%. The tidal exchange through the wide channel during the flood flow occupies 77% of total tidal exchange of the bay through both channels, whereas that during the ebb flow does 88%. The diffusion coefficient of 2.08∼ 2.30 10$\^$7/$\textrm{cm}^2$/sec at the narrow channel was greater than that at the wide channel which was 1.2∼2.8 10$\^$6/$\textrm{cm}^2$/sec.

  • PDF

The Effects of Regular Resistive Exercise on Cardiopulmonary Ability and Cerebral Blood Flow Velocity (규칙적인 저항 운동이 심폐 능력과 뇌혈류 속도에 미치는 영향)

  • Yu, Jae-Ho;Lee, Suk-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.255-264
    • /
    • 2010
  • Purpose : The purpose of this study is to analysis effects of resistive exercise on cardiopulmonary fitness and cerebral artery blood flow velocity. Methods : Ten healthy university students had done resistive exercise without aerobic exercise over one year participated resistive exercise group and ten general university students, then were calculated oxygen consumption ($VO_2$) and respiratory exchange rate($VO_2/VCO_2$). After a week, they were measured Transcranial Doppler Ultrasonography(TCD) at moderate exercise(HRmax 50%), maximal exercise (HRmax 100%) for taking cerebral blood flow velocity. Results : In the comparison between groups, resistive exercise group showed significant higher oxygen consumption and lower respiratory exchange than controls(p<0.05). In resistive exercise group, oxygen consumption was significant negative correlation with cerebral artery pulsatory index(p<0.05). but, oxygen consumption was significant positive correlation with systolic blood flow velocity in controls(p<0.05). Conclusions : After considering all the factors, important value in resistive exercise is regular participation and help us increasing contingency response ability.

The Comparison of Proton Exchange Membrane Fuel Cell According to Flow Field Design (고체고분자전해질형 연료전지의 유로형상에 따른 성능의 비교)

  • LEE, KEON JOO
    • Journal of Digital Convergence
    • /
    • v.19 no.5
    • /
    • pp.279-284
    • /
    • 2021
  • In this study, the performance and distribution of fluid concentration, pressure, and current density of a proton exchange membrane fuel cell was investigated. In this paper, the two different types of flow field design were compared, singel channel and 5-channels. As a result, the 5-channels of flow field showed the better performance than that of single chanel. Especially, the single channel showed better performance in terms of mass transfer loss area.

Groundwater Fluxes in a Watershed with a Lake

  • Bae, Sang-Keun
    • Korean Journal of Hydrosciences
    • /
    • v.7
    • /
    • pp.9-19
    • /
    • 1996
  • The purpose of this study is to investigate the influence of the position of lake upon groundwater fluxes on a lake watershed, and to provide for the monitoring network design to survey the exchange relations between groundwater and lake water. Three kinds of hypothetical flow through lakes, which are located at the upper, middle, and lower portion of a watershed were considered. Groundwater flow for each case was numercally simulated under three-dimensional steady state conditions. The exchange rates of the groundwater, the amounts of recharge and discharge, and groundwater fluxes between lake and groundwater in a watershed system with a lake were clarified.

  • PDF

Aluminum and Plastic Heat Exchange Element : A Performance Comparison for Cooling of Telecommunication Cabinet (통신 함체 냉각용 알루미늄과 플라스틱 열교환 소자의 성능 비교)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.279-288
    • /
    • 2017
  • Heat generation rate in a telecommunication cabinet increases due to the continued usage of mobile devices. Insufficient removal of heat intensifies the cabinet temperature, resulting in the malfunction of electronic devices. In this study, we assessed both aluminum and plastic heat exchangers used for cooling of the telecommunication cabinet, and compared the results against theoretical predictions. The aluminum heat exchanger was composed of counter flow parallel channels of 4.5 mm pitch, and the plastic heat exchangers were composed of cross flow triangular channels of 2.0 mm pitch. Samples were made by installing two plastic heat exchangers in both series and parallel. Results showed that the heat transfer rate was highest for the series cross flow heat exchanger, and was least for the aluminum heat exchanger. The temperature efficiency of the series cross flow heat exchanger was 59% greater than that of the aluminum heat exchanger, and was 4.3% greater than that of the parallel cross flow heat exchanger. In contrast, the pressure drop of the parallel cross flow heat exchanger was significantly lower than other samples. The heat exchange efficiency was also the largest for the parallel cross flow heat exchanger. The theoretical analysis predicted the temperature efficiency to be within 3.3%, and the pressure drop within 6.1%.

Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate (단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발)

  • Yun, Byong-Jo;Kang, Kyong-Ho;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.172-179
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.

  • PDF

Operating Parameters for Glutamic Acid Crystallization in Displacement Ion Exchange Chromatography

  • Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.2 no.2
    • /
    • pp.117-121
    • /
    • 1997
  • Glutamic acid can be crystallized inside cation exchange column when displacer NaOH concentration is high enough to concentrate displaced glutamic acid beyond its solubility limit. Resulting crystal layer of glutamic acid was moved with liquid phase through the column, and thus could be eluted from the column and recovered in fraction collector. For the purpose of enhancing crystal recovery, effects of operating parameters on the crystal formation were investigated. The increase in the degree of crosslinking of resin favored crystal recovery because of its low degree of swelling. Higher concentration of displacer NaOH was advantageous. If NaOH concentration is too high, however, crystal recovery was lowered due to the solubility-enhancing effects of high pH and ionic strength. The decrease of mobile phase flow rate enhanced crystal recovery because enough time to attain local equilibrium could be provided, but film diffusion would control the overall crystal formation with extremely low flow rate. Lower temperature reduced solubility of glutamic acid and thus favored crystal formation unless the rate of ion exchange was severely reduced. The ion exchange operated by displacement mode coupled with crystallization was advantageous in reducing the burden of further purification steps and in preventing purity-loss resulted from overlapping between adjacent bands.

  • PDF

A Design of Clinical Information Exchange Framework for Performance Improvement based on Lazy Response Model (지연 응답 모델에 기반한 성능 개선 진료정보 교류 프레임워크의 설계)

  • Lee, Se-Hoon;Shim, Woo-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.9
    • /
    • pp.157-164
    • /
    • 2012
  • Recently medical service environment, the clinical information exchange which contribute to medical safety, promotion of service quality and patient's convenience, efficiency of medical procedures and medical management is essential medical service model. But, practical exchange of clinical information which variation of information level, absence of standardization system, build of heterogeneous information systems is difficult in each medical institute. In this paper, We analyzed the related technical standardizations and the models of clinical information exchange. So, we designed the clinical information exchange system based on the ideal lazy response model which is aimed at vitalizations the exchange of clinical information under domestic law environment. In case of exchange the clinical information, we separate CDA document flow from metadata flow. As a experimental result we acquired 24% improved performance compared with existed system based on the lazy response model.