• Title/Summary/Keyword: Exchange coupling

Search Result 259, Processing Time 0.031 seconds

The development of high fidelity Steam Generator three dimensional thermal hydraulic coupling code: STAF-CT

  • Zhao, Xiaohan;Wang, Mingjun;Wu, Ge;Zhang, Jing;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.763-775
    • /
    • 2021
  • The thermal hydraulic performances of Steam Generator (SG) under both steady and transient operation conditions are of great importance for the safety and economy in nuclear power plants. In this paper, based on our self-developed SG thermal hydraulic analysis code STAF (Steam-generator Thermalhydraulic Analysis code based on Fluent), an improved new version STAF-CT (fully Coupling and Transient) is developed and introduced. Compared with original STAF, the new version code STAF-CT has two main functional improvements including "Transient" and "Fully Three Dimensional Coupling" features. In STAF-CT, a three dimensional energy transferring module is established which can achieve energy exchange computing function at the corresponding position between two sides of SG. The STAF-CT is validated against the international benchmark experiment data and the results show great agreement. Then the U-shaped SG in AP1000 nuclear power plant is modeled and simulated using STAF-CT. The results show that three dimensional flow fields in the primary side make significant effect on the energy source distribution between two sides. The development of code STAF-CT in this paper can provide an effective method for further SG high fidelity research in the nuclear reactor system.

Magnetic Properties of Hard/Soft Nanocomposite Ferrite Synthesized by Self-Combustion Precursors (자전 연소 전구체로 합성한 나노 크기 경/연 복합페라이트의 자기 특성)

  • Oh, Young Woo;Ahn, Jong Gyeon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.45-50
    • /
    • 2015
  • The goal of this research is the create novel magnets with no rare-earth contents, with larger energy product by comparison with currently used ferrites. For this purpose we developed nano-sized hard-type/soft-type composite ferrite in which high remanent magnetization (Mr) and high coercivity (Hc). Nano-sized Ba-ferrite, Ni-Zn ferrite and $BaFe_{12}O_{19}/Ni_{0.5}Zn_{0.5}Fe_2O_4$ composite ferrites were prepared by sol-gel combustion method by use of glicine-nitrate and citric acid. Nanocomposite ferrites were calcined at temperature range $700-900^{\circ}C$ for 1h. According to the X-ray diffraction patterns and FT-IR spectra, single phase of NiZn-ferrite and Ba-ferrite were detected and hard/soft nanocomposite ferrite was indicated to the coexistence of the magnetoplumbite-structural $BaFe_{12}O_{19}$ and spinel-structural $Ni_{0.5}Zn_{0.5}Fe_2O_4$ that agreed with the standard JCPDS 10-0325 data. The particle size of nanocomposite turn out to be less than 120 nm. The nanocomposite ferrite shows a single-phase magnetization behavior, implying that the hard magnetic phase and soft magnetic phase were well exchange-coupled. The specific saturation magnetization ($M_s$) of the nanocomposite ferrite is located between hard ($BaFe_{12}O_{19}$) and soft ferrite($Ni_{0.5}Zn_{0.5}Fe_2O_4$). The remanence (Mr) of nanocomposite ferrite is much higher than that of the individual $BaFe_{12}O_{19}$ and $Ni_{0.5}Zn_{0.5}Fe_2O_4$ ferrite, and $(BH)_{max}$ is increased slightly.

MnIr Thickness Dependence of Torque Signals in CoFe/MnIr Thin Films (CoFe/MnIr 박막 재료에서 MnIr의 두께에 따른 토오크 신호 분석)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.140-145
    • /
    • 2014
  • We analyzed the MnIr thickness dependence of torque signals measured in exchange coupled CoFe/MnIr ($t_{AF}$) bilayers. The measured torque signals were compared with calculated ones by Stoner-Wohlfarth model. The exchange coupling anisotropy $J_c$ was considered for the model calculation between ferromagnetic (F) and antiferromagnetic (AF) layers with uniaxial anisotropy constant of $K_F$ and $K_{AF}$, respectively. The rotational losses were appeared in the range of $0.5t_c$ < $t_{AF}$ < $t_c$ ($=J_c/K_{AF}$) by the unpinned AF layer. While, the unidirectional anisotropy ($J_k$) was caused by the pinned AF layer at $t_{AF}$ > $t_c$. The critical thickness of MnIr layer was $t_c$ = 3.4 nm in CoFe/MnIr bilayers. The rotational losses behavior as shown in $t_{AF}$ = 3 nm sample were explained by the random orientation of the easy axis of AF grains. The unidirectional anisotropy obtained from torque signal of $t_{AF}$ = 10 nm sample was $J_k=0.63J_c$. Thus, the unidirectional anisotropy can be enhanced up to $J_k=J_c$ by aligning the AF easy axis.

Development of Magnetoimpedance Sensor Utilizing Soft Magnetic Amorphous Ribbon with Exchange Coupling and Application to Nondestructive Testing (교환결합을 가진 연자성 비정질 리본을 이용한 자기 임피던스 센서 개발과 비파괴검사 응용)

  • Yoon, Seok-Soo;Kim, Gun-Woo;Lee, Sang-Hun;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.401-406
    • /
    • 2008
  • Recently, portable magnetic sensors with high sensitivity are strongly required for various applications such as biosensor, nondestructive testing and directional sensor. A novel magnetic sensor system was developed by utilizing giant magnetoimpedance(MI) effect of soft magnetic ribbons. The sensor system consists of sensing head of $Co_{66}Fe_{4}Si_{15}B_{15}$ ribbon having asymmetric MI characteristics through exchange coupling produced by field-annealing in open air and circuit for signal processing. The sensor system showed almost linear characteristics in dynamic range of $-1\;Oe\;{\sim}\;1\;Oe$ and sensitivity of 10.5 V/Oe. The sensor was applicable to nondestructive testing system to detect defects in wire ropes.

Characterization of SPAES Composite Membrane Containing Variously Funtionallized MMT for Direct Methanol Fuel Cell Application (다양한 관능기를 포함한 MMT/SPAES 복합막의 직접 메탄올 연료전지용 적용을 위한 특성평가)

  • Kim, Deuk-Ju;Hwang, Hae-Young;Kim, Se-Jong;Hong, Young-Taik;Kim, Hyoung-Juhn;Leem, Tae-Hoon;Nam, Sang-Yong
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.1
    • /
    • pp.42-50
    • /
    • 2011
  • The Montmorillonite (MMT) in the polymer matrix is expected to reduce methanol permeability due to the tortous path formed by dispersed silicate layers. However, the polymer composite membranes containing non-proton conducting inorganic particle tend to show low proton conductivity. To solve this problem, we used an ion exchange method to prepare functionalized MMT with various silane coupling agents. The modified MMT was randomly dispersed in sulfonated poly (arylene ether sulfone) (SPAES) matrix to prepare SPAES/modified MMT composite membranes. The performances of hybrid membranes for DMFCs application were investigated. The SPAES/modified composite membrane showed increased proton conductivity compared with the non-modified MMT composite membrane. However, the methanol permeability of the SPAES/modified membrane was higher than that of the non-modified MMT.

ThE Variation of Magnetoresistande Ratio and Magnetization Curve by Insertion Co Layer in the$[Ni_{80}Fe_{20}/Cu/Co/Cu]$ Multilayers (교환 결합 상태가 다른 $[Ni_{80}Fe_{20}/Cu/Co/Cu]$ 다층 박막에서 Co 계면 삽입이 자기적 특성에 미치는 영향)

  • 이정주;최상준;홍재화;권순주
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 1998
  • The $[Ni_{80}Fe_{20}/Cu/Co/Cu]$ multilayers were grown by evaporation technique, and according to magnetic exchange coupling relation, magnetoresistance ratio and magnetization curve were studied by Co inserting $Ni_{80}Fe_{20}/Cu$ interface. Insertion of Co layer to the antiferromagnetically coupled system, i. e $t_{Cu} = 25\;{\AA}$, decrese the MR ratio contrary to previous reports. However the insertion to the ferromagneticalyl coupled $(t_{Cu} = 27\;{\AA})$ and the noncoupled $(t_{Cu} = 47\;{\AA})$ systems increase the ratio to 3.5 % and 6 % respectively. The results imply that the insertion change the magnetic exchange coupling state as well as the spin dependent scattering of conduction electrons. Besides, insertion of Co layer between Cu and $Ni_{80}Fe_{20}$ layer enhaces thermal stability to the 300 $^{\circ}C$, which indicates that insertion of Co has a role of the effective diffusion barrier.

  • PDF

Giant Magnetoresistance Behavior and the Effect of Ferromagnetic Layer on the Co-Ag Nano-granular Alloy Films (Co - Ag 합금박막의 거대자기저항 및 강자성 상하지층의 효과)

  • 김용혁;이성래
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • The magnetoresistance and the saturation field behavior of the Co-Ag nano granular films as a function of the composition and the ferromagnetic underlayer and overlayermaterials were investigated. The maximum magnetoresistance of 23% and the saturation field of 2.3 kOe at room temperature were obtained in the as-deposited 3000$\AA$ $Co_{30}Ag_{70}$ single alloy films. The magnetoresistance and the saturation field of 100$\AA$ $Co_{30}Ag-{70}$ alloy film were 3.65 % and 3.0 kOe respectively. Those of the sandwiched films with 200$\AA$ Fe were 3.3 % and 1.23 kOe respectively. The saturation field of the sandwiched alloy films could be reduced by the exchange coupling between the ferromagnetic layers and the alloy layer. The effective depth of the exchange coupling was approximately 150$\AA$ in each Fe layer. Among the Fe, Co, and FeNi, the most effective materials to reduce the saturation field of the sandwiched alloy films was Fe.

  • PDF

Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System (지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발)

  • Shin, Ho-Sung;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.65-73
    • /
    • 2013
  • Ground-coupled heat pump system has attracted attention as a promising renewable energy technology due to its improving energy efficiency and eco-friendly mechanism for space cooling and heating. Pipes buried in the ground play a role of direct thermal interaction between circulating fluid inside the pipe and surrounding soils in the geothermal exchange system. However, both complexities of turbulent flow coupling thermal-hydraulic phenomena and very long aspect ratio of the pipe make it difficult to model the heat exchange system directly. Energy balance for fluid flow inside the pipe was derived to model thermal-hydraulic phenomena, and one-dimensional pipe element was proposed through Galerkin formation and time integration of the equation. Developed element is combined to pre-developed FEM code for THM phenomena in porous media. Numerical results of Thermal Response Test showed that line-source model overestimates equivalent thermal conductivity of surrounding soils due to thermal interaction between adjacent pipes and finite length of the pipe. Thus, inverse analysis for the TRT simulation was conducted to present optimal transformation matrix with utmost convergence.

Determination of a Weak Exchange Interaction in Magnetically Coupled Cluster System by EPR Singlet-Triplet Transition Lines

  • Cho, Young-Hwan;Hyunsoo So
    • Proceedings of the Korean Magnetic Resonance Society Conference
    • /
    • 2002.08a
    • /
    • pp.70-71
    • /
    • 2002
  • Exchange-coupled cluster of transition-metal ions are relevant to many different scientific areas, ranging from chemistry to solid-state physics, biology, material science and has been the subject of much research in recent years(1,2). Single crystal EPR spectroscopy works as a very effective tool for the measurement of J values for small exchange interactions. This makes EPR technique very suitable for detection of weak exchange coupling transmitted over long distances via extended atomic and melecular bridges. Large polyoxometallates (3) may provide ideal structural environments for the study of interactions between paramagnetic ions. The detailed nature of magnetic interaction (positive sign and magnitude of J~0.006 $cm^{-1}$ /) was clearly determined for di-copper(II) system by single crystal EPR spectroscopy (4). The single-triplet (S-T) transitions are forbidden by different symmetries of the wave functions. However, when the singlet ground state is mixed into triplet states, the S-T transitions can be allowed and observed as weak lines. These weak S-T lines are positioned symmetrically with respect to the main transitions in the distance equals to 2J from the center of the spectrum. This lines allow one to determine the J-value with very high accuracy when │J│ < hv 0.32 $cm^{-1}$ /. Unfortunately, the S-T transitions in the single crystal were detected by EPR method only in a few complexes until now. We have measured single-triplet transition lines for several magnetically coupled cluster systems and determined their J values accurately. The temperature dependency of J was studied by monitoring the changes in S-T.

  • PDF

Design and Analysis of Plasmonic Grating-Assisted Directional Coupler based on Silicon Waveguide (실리콘 도파로에 기초한 플리즈마 격자 구조형 방향성 결합기의 설계 및 분석)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.55-60
    • /
    • 2012
  • Longitudinal transmission-line modal theory is applied to analyze maximum power transfer in plasmonic grating-assisted directional couplers (P-GADC) based on silicon waveguide. By defining a coupling efficiency amenable to rigorous analytical solutions and interference between even and odd modes, the power exchange of TE modes as a function of propagation distance is evaluated. The numerical result reveals that maximum power transfer occurs at a grating period ${\Lambda}_{eq}=10.26{\mu}m$, in which the insertion loss of supermodes is equal to each other. That is, it is generally different from conventional phase-matching condition or minium gap condition of GADC.