• Title/Summary/Keyword: Excess Temperature

Search Result 657, Processing Time 0.025 seconds

Preparation of PMN-PT-BT/Ag Composite and its Mechanical and Dielectric Properties (PMN-PT-BT/Ag 복합체 제조 및 기계적, 유전적 특성)

  • Lim, Kyoung-Ran;Jeong, Soon-Yong;Kim, Chang-Sam;Nahm, Sahn
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.9
    • /
    • pp.846-850
    • /
    • 2002
  • A PMN-PT-BT/Ag composite was prepared by surface modification with MgO sol with hoping to suppress silver's migration during sintering. The mixture of PbO, $N_2O_5,\;TiO_2\;with\;Mg(NO_3)_2$ instead of MgO was ball milled, the solvent was removed and then the dried powders were calcined at 950$^{\circ}C$/1h. The calcined powder were treated with 3.0 mol% $Ag_2O$ and 1.0 wt% MgO sol and calcined at 550$^{\circ}C$/1h. The dielectrics sintered at 1000$^{\circ}C$/4h under a flowing oxygen showed the density of 7.84g/$cm^3$, the room temperature dielectric constant of 18400, the dielectric loss of 2.4%, the specific resistivity of $0.24{\times}10^{12}{\Omega}{\cdot}cm$. It also showed the bending strength of $120.7{\pm}11.26$ MPa and the fracture toughness of $0.87{\pm}0.002\;MPam^{1/2}$ which were comparable to commercial PZT. The microstructure sonsisted of grains of ∼4${\mu}m$. SEM and SIMS analysis showed that Ag grew as ∼1${\mu}m$ and excess MgO as ∼0.5${\mu}m$.

Formation of Biogenic Amines by Lactobacillus plantarum Isolated from Makgeolli (막걸리에서 분리한 Lactobacillus plantarum의 biogenic amine 생성능)

  • Kwak, Hee Jung;Kim, Jae Young;Lee, Hyun Sook;Kim, Soon Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.438-445
    • /
    • 2014
  • We examined biogenic amine (BA) production as well as the diversity of bacterial flora in 11 types of commercial makgeolli stored at 4 and $20^{\circ}C$. Moreover, we studied the BA-producing activity of three L. plantarum strains isolated from makgeolli. At $20^{\circ}C$, the BA content was highly increased and the denatured DNA bands were more variable in non-sterilized makgeolli compared to sterilized makgeolli. The major BAs produced in commercial makgeolli were histamine and putrescine. Histamine, tyramine, putrescine, and cadaverine were produced in excess by inoculation of the three L. plantarum isolates to makgeolli stored at $20^{\circ}C$ for 21 days. These results suggest that some L. plantarum strains in makgeolli can produce different types of BAs, depending on the extent of degradation of makgeolli.

Characteristics of ferroelectric $YMnO_3$ thin film with low dielectric constant for NDRO FRAM (비파괴 판독형 메모리 소자를 위한 저유전율 강유전체 $YMnO_3$박막의 특성 연구)

  • 김익수;최훈상;최인훈
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.258-262
    • /
    • 2000
  • $YMnO_3$thin films are deposited on Si(100) and $Y_2O_3/Si(100)$ substrate by radio frequency sputtering. The deposition condition of oxygen partial pressure and annealing temperature have significant influences on the preferred orientation of $YMnO_3$film and the size of memory window. The results of x-ray diffraction show that the film deposited in the oxygen partial pressure of 0% is highly oriented along c-axis after annealing at $870^{\circ}C$ for 1 hr in oxygen ambient. However, the films deposited on Si and $Y_2O_3/Si$ in the oxygen partial pressures of 20% show $Y_2O_3$ peak, the excess $Y_2O_3$ in the $YMnO_3$film suppresses the c-axis oriented crystallization. Especially memory windows of the $Pt/YMnO_3/Y_2O_3/Si$ capacitor are 0.67~3.65 V at applied voltage of 2~12 V, which is 3 times higher than that of the film deposited on $Y_2O_3/Si$ in 20% oxygen (0.19~1.21 V) at the same gate voltage because the film deposited in 0% oxygen is well crystallized along c-axis.

  • PDF

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

Characteristics of RDF Char Combustion in a Bubbling Fluidized Bed (기포 유동층 내에서 RDF 촤의 연소 특성)

  • Kang, Seong-Wan;Kwak, Yeon-Ho;Cheon, Kyoung-Ho;Park, Sung Hoon;Jeon, Jong-Ki;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.429-432
    • /
    • 2011
  • The feasibility of applications of the char obtained from a gasification process of municipal-waste refuse derived fuel (RDF) as an auxiliary fuel was evaluated by combustion experiments. The higher heating value of the RDF char was 3000~4000 kcal/kg and its chlorine content was below the standard requirement demonstrating its potential as an auxiliary fuel. In the combustion exhaust gas, the maximum $NO_x$ and $SO_2$ concentrations were 240 ppm and 223 ppm, respectively. If an aftertreatment is applied, it is possible to control their concentrations low enough to meet the air pollutant emission standard. The HCl concentration was relatively high indicating that a care should be taken for HCl emission from the combustion of RDF. Based on the temperature distribution within the reactor, the concentration change of $O_2$ and $CO_2$, and the amount and the loss on ignition of solid residue, it was inferred that the combustion reaction was the most reliable when the excess air ratio of 1.3 was used.

Degradation kinetics of vitamins in premixes for pig: effects of choline, high concentrations of copper and zinc, and storage time

  • Yang, Pan;Wang, Hua Kai;Zhu, Min;Li, Long Xian;Ma, Yong Xi
    • Animal Bioscience
    • /
    • v.34 no.4
    • /
    • pp.701-713
    • /
    • 2021
  • Objective: The present work was undertaken to evaluate the effects of storage time, choline chloride, and high concentrations of Cu and Zn on the kinetic behavior of vitamin degradation during storage in two vitamin premixes and four vitamin-trace mineral (VTM) premixes. Methods: Two vitamin premixes (with or without 160,000 mg/kg of choline) were stored at 25℃ and 60% humidity. Besides, four VTM premixes were used to evaluate the effects of choline (0 vs 40,000 mg/kg) and trace minerals (low CuSO4+ZnO vs high CuSO4+ZnO) on vitamin stability in VTM premixes stored in room, and the VTM premixes were stored in room temperature at 22℃. Subsamples from each vitamin and VTM premix were collected at 0, 1, 2, 3, 6, and 12 months. The retention of vitamin A (VA), vitamin D3 (VD3), vitamin E (VE), vitamin K3 (VK3), vitamin B1 (VB1), vitamin B2 (VB2), vitamin B3 (VB3), vitamin B5 (VB5), and vitamin B6 (VB6) in vitamin premixes and VTM premixes during storage was determined. The stability of vitamins in vitamin premixes and VTM premixes was determined and reported as the residual vitamin activity (% of initial) at each sampling point. Results: The effect of choline on VK3 retention was significant in vitamin premixes (p<0.05). The negative effect of storage time was significant for the retentions of VD3, VK3, VB1, VB2, VB5, and VB6 in vitamin premix (p<0.05). For VTM premixes, negative effect of storage time was significant (p<0.05) for the losses of vitamin in VTM premixes. Choline and high concentrations of Cu and Zn significantly increased VA, VK3, VB1, and VB2 loss during storage (p<0.05). The supplementation of high concentrations of Cu and Zn significantly decreased the concentrations of VD3 and VB6 (p<0.05) in VTM premixes at extended storage time. Conclusion: The maximum vitamin stability was detected in vitamin and VTM premixes containing no choline or excess Cu and Zn. The results indicated that extended storage time increased degradation of vitamin in vitamin or VTM premixes. These results may provide useful information for vitamin and VTM premixes to improve the knowledge of vitamin in terms of its stability.

Effects of Soil Water Content on Growth and Antioxidative Enzymes of Tomato Plug Seedlings (토양 수분함량이 토마토 묘의 생육 및 항산화 효소에 미치는 영향)

  • Kim, D.E.;Kang, J.K.;Shin, Y.A.;Hong, S.J.;Lee, W.Y.;Woo, Y.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.21 no.2
    • /
    • pp.59-69
    • /
    • 2019
  • This study was carried out to investigate effects of soil water content on growth and antioxidative enzymes activity of tomato seedlings during the nursery period. The water stress significantly damages morphological, physiological, and biochemical activities in plants. The seedlings planted with soil on the tray were irrigated and categorized into 3 groups with 30 g, 40 g, and 50 g of plant-soil weight. After then, the changes in weight of the soil and the seedling were measured evey 2 hours for 4 days and the leaf temperature was measured with the thermal-camera at the same time. The antioxidant enzymes were measured to determine the level of stress using all of the seedling samples. The result showed that the decrease of soil weight in the day time was faster than that in the night time, but there was no significant difference in the weight loss of the seedlings and soil among the groups. However, the group with 50 g of wight showed the highest SOD and POD contents. This is considered that the continuously wet soil on the root zone of the seedlings caused more stress for the seedlings. Therefore, it is concluded that the excess moisture content causes stress to stimulate the secretion of antioxidant enzymes, and the effect of stress is required to be analyzed comprehensively using environmental data and also the physiological data that are collected over a longer period.

Evaluation of Health Impact of Heat Waves using Bio-Climatic impact Assessment System (BioCAS) at Building scale over the Seoul City Area (생명기후분석시스템(BioCAS)을 이용한 폭염 건강위험의 검증 - 서울시 건물규모를 중심으로 -)

  • Kim, Kyu Rang;Lee, Ji-Sun;Yi, Chaeyeon;Kim, Baek-Jo;Janicke, Britta;Holtmann, Achim;Scherer, Dieter
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • The Bio-Climatic impact Assessment System, BioCAS was utilized to produce analysis maps of daily maximum perceived temperature ($PT_{max}$) and excess mortality ($r_{EM}$) over the entire Seoul area on a heat wave event. The spatial resolution was 25 m and the Aug. 5, 2012 was the selected heat event date. The analyzed results were evaluated by comparing with observed health impact data - mortality and morbidity - during heat waves in 2004-2013 and 2006-2011,respectively. They were aggregated for 25 districts in Seoul. Spatial resolution of the comparison was equalized to district to match the lower data resolution of mortality and morbidity. Spatial maximum, minimum, average, and total of $PT_{max}$ and $r_{EM}$ were generated and correlated to the health impact data of mortality and morbidity. Correlation results show that the spatial averages of $PT_{max}$ and $r_{EM}$ were not able to explain the observed health impact. Instead, spatial minimum and maximum of $PT_{max}$ were correlated with mortality (r=0.53) and morbidity (r=0.42),respectively. Spatial maximum of $PT_{max}$, determined by building density, affected increasing morbidity at daytime by heat-related diseases such as sunstroke, whereas spatial minimum, determined by vegetation, affected decreasing mortality at nighttime by reducing heat stress. On the other hand, spatial maximum of $r_{EM}$ was correlated with morbidity (r=0.52) but not with mortality. It may have been affected by the limit of district-level irregularity such as difference in base-line heat vulnerability due to the age structure of the population. Areal distribution of the heat impact by local building and vegetation, such as spatial maximum and minimum, was more important than spatial mean. Such high resolution analyses are able to produce quantitative results in health impact and can also be used for economic analyses of localized urban development.

Intracellular Concentrations of NAD(P), NAD(P)H, and ATP in a Simulated Oxic-settling-anaerobic (OSA) Process (OSA 공정의 세포 내 ATP, NAD(H), NADP(H) 농도)

  • Ventura, Jey-R Sabado;Nam, Ji-Hyun;Yang, Benqin;Na, Ri;Kil, Hyejin;Nam, Deok-Hyeon;Kang, Ki-Hoon;Jahng, Deokjin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.599-609
    • /
    • 2015
  • In order to investigate why OSA (oxic-settling-anaerobic) process produces less sludge than CAS (conventional activated sludge) process, sequential cultivation through 1st aerobic-anaerobic-2nd aerobic conditions, were carried out. Then, the intracellular concentrations of adenosine triphosphate (ATP), nicotinamide adenine dinucleotide (NAD and NADH), and nicotinamide adenine dinucleotide phosphate (NADP and NADPH) were monitored for these three stages. Results showed that the concentrations of these energy substances rapidly decreased through time in both aerobic and anaerobic conditions but the anaerobic culture contained the lower energy level than aerobic culture. The 2nd aerobic culture that experienced anaerobic condition showed lower concentration of these energy substances than those of the 1st aerobic culture. Meanwhile, the anaerobic culture corresponding to the sludge holding stage of OSA was subjected to different soluble chemical oxygen demand (SCOD) levels, detention time, and temperature to evaluate the effects of these variations on the energy level difference between the 1st and 2nd aerobic stages. The lower the SCOD concentration, the longer detention time; and the higher temperature in the anaerobic stage tended to further reduce the intracellular level of the 2nd aerobic culture. On the average, the intracellular energy level of the anaerobic and 2nd aerobic stage were 57.73% and 39.12% of the 1st aerobic culture, respectively. These indicated that the insertion of an anaerobic stage between two aerobic stages could lower the intracellular energy levels, hence the lower the sludge in OSA than CAS process. Moreover, manipulation of the operating conditions of the intervening anaerobic stage can change intracellular energy levels thereby controlling sludge production.

Studies on Wet Paddy Field Underdrainage Improvement in the Gum-Ho Area (I) (금호지구 저습답의 암거배수효과에 관한 연구(I))

  • 김조웅;김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.4
    • /
    • pp.82-95
    • /
    • 1980
  • This paper complies the results of the studies so far made on the subsoil improvement of subsurface drainage systems for wet paddy fields (those were located in the Gum-Ho area in Kyung Buk province) which had poor permeability and a high water table. In general, a drainage problem is an excess of water on the ground surface which can effect the productivity and bearing capacity of the soil. With drain pipe systems, (According to their depths and spacing) it may be possible to correct that problem. The experimentation consisted of three test plots, two of which included drain pipe systems with varing depths and width spacing of the pipes. The third plot (C) was an ordinary plot being exempt of a drain pipe system. In detail, the depth of plot A was 80 cm, and the width spacings began at 2. Om and increased by 2. Om up to 10. 0m. The depth of plot B was 60cm and the width spacing was the same as plot A. These tests were performed to research specific details; such as crop yeild, bearing capacity of the soil, the amount of underdrainage, surface cracks, root distribution, the water table level, the consumptive water depth and the soil moisture content. The test period lasted three years, from 1977 thru 1979. The results obtained were as follows: 1. During the test period, the weather conditions for the area tested were in accordance with the annual average for that area. Furthermore the precipitation factor during the spring cultivation season, the intermediate drainage period and the harvest drainage period was of optimum conditions for controling surface cracks, because of less precipitation than evaporation. 2. The difference in the level of the ground water table in plots A and B was hardly noticable, but the difference in the test plots and the ord. plot was greatly noticable. The test plots (A, B) were 30 to 40cm lower than the ordinary plot. On the whole, the ground water table of the ord. plot always stayed at a level of 15-20cm beneath the surface of the soil, the ground water table of the test plot A showed The difference in the depth of the pipe lower than the test plot B, while the test plots showed a remarkable descending effect. 3. The soil temperature in plot A was slightly core than in plot B with a difference of 0. 47$^{\circ}$C, but plot A was 1. 6$^{\circ}$C higher than the ord. plot during the flooding period, but after drainage the temperature difference climed to 2. 0$^{\circ}$C. 4. During the 3rd test year, the values of the cracks were recorded with the values of 59cm in plot A, 42cm in plot B and 15cm in the ordinary plot. Plots A and B had increased 2.5 times the value of the first year while the ordinary plot had remained the same. 5. The root weight of the rice was measured at a value of 77.2 gr. for plot A, 73.5 gr. for plot B and 65.3 gr. for the ord. plot. Therefore, the root growths in plots A and B were much more energetic than in the ord. plot. 6. The consumptive water depth measured during the 3rd year resulted in the values of 26. 0mm per day for plot A, and 24.9 mm per day for plot B, respectively. Therefore, both plot A and plot B maintained the optimum consumptive water depths, but the ordinary plot only obtained the value of 12.3 mm per day, which clearly showed less than the optimum consumptive water depth which is 20 to 30 mm/day. 7. The soil moisture content is in direct relationship to the ground water level. During drainage, test plot A decreased in its ground water level much more rapidly than the other two plots. Therefore, plot A had a much less soil moisture content. But this decreased water level could be directly effected by the weather conditions. 8. The relationship between the bearing capacity and the soil moisture content were directly inversely proportional. It can be assumed that the occurence of soil creaks is limited by the soil moisture content. Therefore, the greater the progress of the surface creaks resulted in a greater bearing capacity. So, tast plot A with a greater amount of surface cracks than the other test plots resulted in a greater bearing capacity. But, the bearing capacity at the harvest season could be effected by the drainage during the intermediate drainage period and by the weather conditions. 9. Comparing the production of the test plots to the ord. plot; there was an increased value of 840kg for plot A, 755kg for plot B and 695kg for the ord. plot in the rough rice. Therefore, plot A had an increase of 20% over the ordinary plot. The possibility of producing double crops was investigated. The effects on barley production in the test plots showed a value of 367kg per 10 acres, which substantiated the possibility of double crops because that value showed an increased value over the average yearly yield for those uplands. 10. So as a result, it can be recommended that by including a drain pipe system with the optimum conditions of an (80cm centimeter) depth and a (l0m) spacing will have a definite positive effect on the over all production capacity and quality of wetpaddy fields.

  • PDF