• 제목/요약/키워드: Excess Attenuation

검색결과 14건 처리시간 0.028초

지표면에 의한 음의 초과 감쇠 특성 연구 (A Study on the Characteristics of Excess Attenuation of the Sound due to the Ground)

  • 황철호;정성수
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.401-409
    • /
    • 1997
  • This study observed the meterological influence on the excess attenuation with various flow resistivities. The flow resistivity is simulated up to 30, 000 cgs rayls. There is no significant differences among results from spherical wave analysis for excess attenuation, from plane wave analysis, and from locally reacting analysis. This is validated only when the flow resistivity is more than 100 cgs rayls. For the determination of effective flow resistivity of ground by measuring the excess attenuation experimentally, it is highly recommended that the distance between source and receiver is about 2.5m, and that the height of them is 0.3-0.4 m in case that they have the same height. Under this proposed conditions, the flow resistivity of 6-month-passed asphalt ground is estimated to 5, 000 cgs rayls by comparing the measured excess attenuation with the calculated.

  • PDF

지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구 (A study of estimation for excess attenuation of Noise propagated on the ground)

  • 오재응;김동규;임동규
    • 한국음향학회지
    • /
    • 제7권2호
    • /
    • pp.20-25
    • /
    • 1988
  • 본 연구는 소음전파에 대한 옥외실험과 축적 음향모형실험에 의해서 지표면에 의한 초과감쇠 특징을 밝힌 것으로써, 옥외실험에 의한 소음전파감쇠는 음향출력이 큰 소형엔진을 사용하여, 거리감쇠로부터 산출한 실측의 초과감쇠와 Log(D/(Hs+Hr))의 관계를 확인했다. 그 결과 소음전파감쇠는 풍향, 주파수에 따라 다르며 직선회귀 된다는 것을 알 수 있었다. 그리고, 지표면상의 초과감쇠치는 통기저항을 이용해서 Log(D/Hs+Hr))을 파라미터로써 구할 수 있었고, 가장 적당한 통기저항$\sigma$는 실측의 초과감쇠치와 임의의 $\sigma$에 대한 $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ 식의 평균자승 오차가 가장 적어질 때 결정된다. 모형의 지표로써 축척 1/40의 모형실험으로, 큰 무향실내에서 거리감쇠의 측정을 한 결과, 실측치와의 대응이 충분하다는 것을 확인했다.

  • PDF

지표면 임피던스에 의한 소음의 초과감쇠에 관한 연구 (Effects of the Finite Ground Impedance on the Excess Attenuation of Noise)

  • 김동일;강병용;장호경;김예현
    • 한국음향학회지
    • /
    • 제13권5호
    • /
    • pp.5-14
    • /
    • 1994
  • 본 연구에서는 초지, 흙으로 된 표면, 아스팔트, 시멘트도로 등의 지표면 위의 자유공간에서 정상파 방법을 이용하여 음향 임피던스를 측정하였으며, 음의 초과감쇠를 조사하였다. 사용한 주파수의 범위는 300Hz에서 1000Hz이며, 각 지표면의 음향 임피던스를 측정한 결과 Delany와 Bazley의 이론식과 비교적 잘 일치하였다. 음향임피던스는 초지, 흙, 아스팔트, 시멘트도로의 순으로 커지고, 주파수가 증가하면 그 값은 감소한다. 음의 초과감쇠는 주로 음향임피던스에 의해 좌우됨을 확인하였으며, 각 지표면과 마이크로폰의 높이에 따른 이론치와 실험결과를 비교하였다.

  • PDF

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

In-line Variable Attenuator Based on the Evanescent Wave Coupling Between a Side-polished Single-mode Fiber and an Index Matched Dielectric Plate

  • Kim, Kwang-Taek;Kim, Hyo-Kyeom
    • Journal of the Optical Society of Korea
    • /
    • 제8권1호
    • /
    • pp.17-20
    • /
    • 2004
  • An in-line variable attenuator has been proposed and demonstrated exploiting a side-polished single-mode (SM) fiber evanescently coupled with an index matched dielectric plate. The attenuation can be controlled by fine mechanical sliding of the index matched dielectric plate. We have achieved 49 ㏈ dynamic range and very low excess loss of 0.2 ㏈ at 1550 nm wavelength. The measured polarization dependent losses (PDL) were 0.1, 0.2, and 0.4 ㏈ at 10, 20, and 30 ㏈ attenuation, respectively. Wavelength sensitivity was measured to be -0.017/nm ㏈ at 20 ㏈ attenuation.

In-line Variable Optical Attenuator Based on the Bending of the Tapered Single Mode Fiber

  • Kim, Kwang-Taek;Kang, Ji-Hoon;HwangBo, Seung;Im, Kie-Gon
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.349-353
    • /
    • 2009
  • We propose a simple in-line variable optical attenuator (VOA) based on the bending effect of tapered single mode fibers. The influence of the taper structure and the reflective index of the external medium surrounding the taper region on the bending loss of the tapered fiber have been investigated experimentally. An attenuation range exceeding 35 dB and a very low excess loss of < 0.2 dB at 1550 nm were achieved. The measured polarization dependent loss of the present VOA at the attenuation level of 10 dB, 20 dB, and 30 dB were 0.1 dB, 0.2 dB, and 0.5 dB, respectively.

Imbalance in the spinal serotonergic pathway induces aggravation of mechanical allodynia and microglial activation in carrageenan inflammation

  • Junxiu Jin;Dong Ho Kang;Jin Jeon;Hyung Gon Lee;Woong Mo Kim;Myung Ha Yoon;Jeong Il Choi
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.51-59
    • /
    • 2023
  • Background: This study investigated the effect of an excess and a deficit of spinal 5-hydroxytryptamine (5-HT) on the mechanical allodynia and neuroglia activation in a rodent pain model of carrageenan inflammation. Methods: Male Sprague-Dawley rats were implanted with an intrathecal (i.t.) catheter to administer the drug. To induce an excess or deficit of 5-HT in the spinal cord, animals were given either three i.t. 5-HT injections at 24-hour intervals or a single i.t. injection of 5,7-dihydroxytryptamine (5,7-DHT) before carrageenan inflammation. Mechanical allodynia was measured using the von Frey test for 0-4 hours (early phase) and 24-28 hours (late phase) after carrageenan injection. The changes in the activation of microglia and astrocyte were examined using immunofluorescence of the dorsal horn of the lumbar spinal cord. Results: Both an excess and a deficit of spinal 5-HT had no or a minimal effect on the intensity of mechanical allodynia during the early phase but prevented the attenuation of mechanical allodynia during the late phase, which was observed in animals not treated with i.t. 5-HT or 5,7-DHT. Animals with an excess or deficit of 5-HT showed stronger activation of microglia, but not astrocyte, during the early and late phases, than did normal animals. Conclusions: Imbalance in the descending 5-HT pathway in the spinal cord could aggravate the mechanical allodynia and enhance the activation of microglia, suggesting that the spinal 5-HT pathway plays an essential role in maintaining the nociceptive processing in balance between facilitation and inhibition in inflammatory pain caused by carrageenan inflammation.

Compact Multi-harmonic Suppression LTCC Bandpass Filter Using Parallel Short-Ended Coupled-Line Structure

  • Wang, Xu-Guang;Yun, Young;Kang, In-Ho
    • ETRI Journal
    • /
    • 제31권3호
    • /
    • pp.254-262
    • /
    • 2009
  • This paper presents a novel simple filter design method based on a parallel short-ended coupled-line structure with capacitive loading for size reduction and ultra-broad rejection of spurious passbands. In addition, the introduction of a cross-coupling capacitor into the miniaturized coupled-line can create a transmission zero at the second harmonic frequency for better frequency selectivity and attenuation level. The aperture compensation technique is also applied to achieve a strong coupling in the coupled-line section. The influence of using the connecting transmission line to cascade two identical one-stage filters is studied for the first time. Specifically, such a two-stage bandpass filter operating at 2.3 GHz with a fractional bandwidth of 10% was designed and realized with low-temperature co-fired ceramic technology for application in base stations that need high power handling capability. It achieved attenuation in excess of -40 dB up to $4f_0$ and low insertion loss of -1.2 dB with the size of 10 mm ${\times}$ 7 mm ${\times}$ 2.2 mm. The measured and simulated results showed good agreement.

Microsized Corn-Oil Droplet (MOD)의 Trichloroethylene (TCE) 생물학적 탈염소화 분해 자연저감 완효성 촉진제 적용성 평가 (Feasibility of Natural Attenuation for TCE Anaerobic Reductive Dechlorination Using Microsized Corn-Oil Droplet as an Activator)

  • 한경진;김희윤;권수열;김영
    • 한국물환경학회지
    • /
    • 제40권1호
    • /
    • pp.11-18
    • /
    • 2024
  • Recently, enhanced in situ bioremediation using slow substrate release techniques has been actively researched for managing TCE-contaminated groundwater. This study conducted a lab-scale batch reactor experiment to evaluate the feasibility of natural attenuation for TCE dechlorination using microsized corn-oil droplet (MOD) as an activator considering the following three factors: 1) TCE dechlorination in the presence or absence of MOD; 2) TCE dechlorination in the presence or absence of inactivator of native microbial activity; and 3) MOD concentration effects on TCE dechlorination. Batch reactors were constructed using site groundwater and soil in which Dehalococcoides bacteria were present. Without MOD, TCE was decomposed into dichloroethylene (DCE). However, other by-products of TCE dechlorination were not detected. With MOD, DCE, vinyl chloride (VC), and ethylene (ETH) were sequentially observed. This result confirmed that MOD effectively supplied electrons to complete dechlorination of TCE to ETH. However, when an excess of MOD was provided, it formed unfavorable conditions for anaerobic digestion because dechlorination reaction did not proceed while propionic acid was accumulated after DCE was generated. Therefore, if an appropriate amount of MOD is supplied, MOD can be effectively used as a natural reduction activator to promote biodegradation in an aquifer contaminated by TCE.

고속철도 터널내를 전파하는 압축파의 일차원 수치해석 (One-Dimensional Numerical Study of Compression Wave Propagating in High-Speed Railway Tunnel)

  • 김희동;엄용균;송미일태
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1280-1290
    • /
    • 1995
  • In order to investigate the compression wave propagating in a high-speed railway tunnel, a numerical calculation was applied to the wave phenomenon occurring in a model tunnel. Unsteady, one-dimensional inviscid or viscous flows were solved by an explicit TVD scheme, and the calculated flows were compared with the results of measurement in real tunnels. Tunnel noises caused by emission of the compression wave were characterized in terms of excess pressure of compression wave, pressure gradient in the wave front and width of the compression wave. Calculated attenuation, pressure gradient and width of compression wave with the propagating distance agreed with the results of measurement in the real tunnels. The results also show that tunnel noises are proportional to the train velocity entering the tunnel.