• Title/Summary/Keyword: Excess Absolute Risk

Search Result 5, Processing Time 0.022 seconds

Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer (자궁경부암 근접치료 시 선량 검증 프로그램을 통한 임상적 위험성 평가)

  • Dong‑Jin, Kang;Young‑Joo, Shin;Jin-Kyu, Kang;Jae‑Yong, Jung;Woo-jin, Lee;Tae-Seong, Baek;Boram, Lee
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.553-560
    • /
    • 2022
  • The purpose of this study is to evaluate the clinical risk according to the applicator heterogeneity, mislocation, and tissue heterogeneity correction through a dose verification program during brachytherapy of cervical cancer. We performed image processing with MATLAB on images acquired with CT simulator. The source was modeled and stochiometric calibration and Monte-Carlo algorithm were applied based on dwell time and location to calculate the dose, and the secondary cancer risk was evaluated in the dose verification program. The result calculated by correcting for applicator and tissue heterogeneity showed a maximum dose of about 25% higher. In the bladder, the difference in excess absolute risk according to the heterogeneity correction was not significant. In the rectum, the difference in excess absolute risk was lower than that calculated by correcting applicator and tissue heterogeneity compared to the water-based calculation. In the femur, the water-based calculation result was the lowest, and the result calculated by correcting the applicator and tissue heterogeneity was 10% higher. A maximum of 14% dose difference occurred when the applicator mislocation was 20 mm in the Z-axis. In a future study, it is expected that a system that can independently verify the treatment plan can be developed by automating the interface between the treatment planning system and the dose verification program.

Excess Deaths During the COVID-19 Pandemic in Southern Iran: Estimating the Absolute Count and Relative Risk Using Ecological Data

  • Mohammadreza Zakeri;Alireza Mirahmadizadeh;Habibollah Azarbakhsh;Seyed Sina Dehghani;Maryam Janfada;Mohammad Javad Moradian;Leila Moftakhar;Mehdi Sharafi;Alireza Heiran
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.2
    • /
    • pp.120-127
    • /
    • 2024
  • Objectives: The coronavirus disease 2019 (COVID-19) pandemic led to increased mortality rates. To assess this impact, this ecological study aimed to estimate the excess death counts in southern Iran. Methods: The study obtained weekly death counts by linking the National Death Registry and Medical Care Monitoring Center repositories. The P-score was initially estimated using a simple method that involved calculating the difference between the observed and expected death counts. The interrupted time series analysis was then used to calculate the mean relative risk (RR) of death during the first year of the pandemic. Results: Our study found that there were 5571 excess deaths from all causes (P-score=33.29%) during the first year of the COVID-19 pandemic, with 48.03% of these deaths directly related to COVID-19. The pandemic was found to increase the risk of death from all causes (RR, 1.26; 95% confidence interval [CI], 1.19 to 1.33), as well as in specific age groups such as those aged 35-49 (RR, 1.21; 95% CI, 1.12 to 1.32), 50-64 (RR, 1.38; 95% CI, 1.28 to 1.49), and ≥65 (RR, 1.29; 95% CI, 1.12 to 1.32) years old. Furthermore, there was an increased risk of death from cardiovascular diseases (RR, 1.17; 95% CI, 1.11 to 1.22). Conclusions: There was a 26% increase in the death count in southern Iran during the COVID-19 pandemic. More than half of these excess deaths were not directly related to COVID-19, but rather other causes, with cardiovascular diseases being a major contributor.

Conclusions and Suggestions on Low-Dose and Low-Dose Rate Radiation Risk Estimation Methodology

  • Sakai, Kazuo;Yamada, Yutaka;Yoshida, Kazuo;Yoshinaga, Shinji;Sato, Kaoru;Ogata, Hiromitsu;Iwasaki, Toshiyasu;Kudo, Shin'ichi;Asada, Yasuki;Kawaguchi, Isao;Haeno, Hiroshi;Sasaki, Michiya
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.1
    • /
    • pp.14-23
    • /
    • 2021
  • Background: For radiological protection and control, the International Commission on Radiological Protection (ICRP) provides the nominal risk coefficients related to radiation exposure, which can be extrapolated using the excess relative risk and excess absolute risk obtained from the Life Span Study of atomic bomb survivors in Hiroshima and Nagasaki with the dose and dose-rate effectiveness factor (DDREF). Materials and Methods: Since it is impossible to directly estimate the radiation risk at doses less than approximately 100 mSv only from epidemiological knowledge and data, support from radiation biology is absolutely imperative, and thus, several national and international bodies have advocated the importance of bridging knowledge between biology and epidemiology. Because of the accident at the Tokyo Electric Power Company (TEPCO)'s Fukushima Daiichi Nuclear Power Station in 2011, the exposure of the public to radiation has become a major concern and it was considered that the estimation of radiation risk should be more realistic to cope with the prevailing radiation exposure situation. Results and Discussion: To discuss the issues from wide aspects related to radiological protection, and to realize bridging knowledge between biology and epidemiology, we have established a research group to develop low-dose and low-dose-rate radiation risk estimation methodology, with the permission of the Japan Health Physics Society. Conclusion: The aim of the research group was to clarify the current situation and issues related to the risk estimation of low-dose and low-dose-rate radiation exposure from the viewpoints of different research fields, such as epidemiology, biology, modeling, and dosimetry, to identify a future strategy and roadmap to elucidate a more realistic estimation of risk against low-dose and low-dose-rate radiation exposure.

Dosimetric Comparison of Radiation Treatment Techniques for Breast Cancer : 3D-CRT, IMRT and VMAT (유방암 방사선치료 기법에 따른 선량 비교 : 3차원 입체조형치료, 세기 변조 방사선치료, 입체세기조절회전 방사선치료)

  • Lee, Bo-Ram;Lee, Sun-Young;Yoon, Myong-Geun
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.237-244
    • /
    • 2013
  • The purpose of this study is to compare method in the treatment of breast cancer using dose index. And, it is to find the optimized treatment technique to the patient. The phantom filled with tissue-equivalent material were used simulation and treatment as techniques of 3D-CRT, IMRT, VMAT was planned using Eclipse v10. By using HI(homogeneity index), CI(Conformity index), OED(Organ equivalent dose), EAR(Excess Absolute Risk), were assessed for each treatment plans. HI and CI of 3D-CRT, IMRT, VMAT were calculated 16.89, 11.21, 9.55 and 0.59, 0.61, 0.83. The organ average doses of Lt lung, Rt lung, liver, heart, esophagus, cord, Lt breast, trachea and stomach were 0.01 ~ 2.02 Gy, 0.36 ~ 5.01 Gy, 0.25 ~ 2.49 Gy, 0.14 ~ 6.92 Gy, 0.03 ~ 2.02 Gy, 0.01 ~ 1.06 Gy, 0.25 ~ 6.08 Gy, 0.08 ~ 0.59 Gy, 0.01 ~ 1.34 Gy, respectively. The OED, EAR of the IMRT and VMAT show higher than 3D-CRT. As the result of this study, we could confirm being higher dose index(HI, CI) in IMRT and VMAT than 3D-CRT, but doses of around normal organs was higher IMRT, VMAT than 3D-CRT.

Comparison of Electrodermal Activity between Hypertensive and Non-hypertensive Subject in Health Screening Population (건강검진자 대상 고혈압 유무에 따른 피부전기활동성 비교 연구)

  • Kim, Young Eun;Kim, Chul;Yea, Sang Jun;Yang, Chang Sop;Song, Mi Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.6
    • /
    • pp.847-852
    • /
    • 2013
  • The aim of this study was to investigate the difference of electrodermal activity between the hypertensive and non-hypertensive subjects. A total 161 subjects who visited a hospital for health check ups from August 2011 through November 2011 and from September 2012 through November 2012 were included in this study. We divided the subjects into two groups by blood pressure, hypertension group(81 patients) and non-hypertension group(180 subject). Then we compared electrodermal activity between two groups by using the autonomic bioelectric response device model CP-6000A. The data was analyzed by independent t-test and logistic regression. In this study, there was a significant difference in electrodermal activity(the mean absolute value of positive, negative pulse conductivity) between hypertensive and normotensive group in t-test and electrodermal activity showed the significant influence on the prevalence risk of hypertension with age, body mass index and dyslipidema in binominal logistic regression. In conclusion, hypertensive patients had high level of electrodermal activity compared with normotensive subjects and this finding suggests that electrodermal activity which is explained excess tendency in Korean traditional medicine could be used for diagnosis in hypertension patients at Korean traditional medical clinic.