• Title/Summary/Keyword: Exceedance probability method

Search Result 42, Processing Time 0.03 seconds

Application of probabilistic method to determination of aerodynamic force coefficients on tall buildings

  • Yong Chul Kim;Shuyang Cao
    • Wind and Structures
    • /
    • v.36 no.4
    • /
    • pp.249-261
    • /
    • 2023
  • Aerodynamic force coefficients are generally prescribed by an ensemble average of ten and/or twenty 10-minute samples. However, this makes it difficult to identify the exact probability distribution and exceedance probability of the prescribed values. In this study, 12,600 10-minute samples on three tall buildings were measured, and the probability distributions were first identified and the aerodynamic force coefficients corresponding to the specific non-exceedance probabilities (cumulative probabilities) of wind load were then evaluated. It was found that the probability distributions of the mean and fluctuating aerodynamic force coefficients followed a normal distribution. The ratios of aerodynamic force coefficients corresponding to the specific non-exceedance probabilities (Cf,Non) to the ensemble average of 12,600 samples (Cf,Ens), which was defined as an adjusting factor (Cf,Non/Cf,Ens), were less than 2%. The effect of coefficient of variation of wind speed on the adjusting factor is larger than that of the annual non-exceedance probability of wind load. The non-exceedance probabilities of the aerodynamic force coefficient is between PC,nonex = 50% and 60% regardless of force components and aspect ratios. The adjusting factors from the Gumbel distribution were larger than those from the normal distribution.

Monte Carlo analysis of the induced cracked zone by single-hole rock explosion

  • Shadabfar, Mahdi;Huang, Hongwei;Wang, Yuan;Wu, Chenglong
    • Geomechanics and Engineering
    • /
    • v.21 no.3
    • /
    • pp.289-300
    • /
    • 2020
  • Estimating the damage induced by an explosion around a blast hole has always been a challenging issue in geotechnical engineering. It is difficult to determine an exact dimension for damage zone since many parameters are involved in the formation of failures, and there are some uncertainties lying in these parameters. Thus, the present study adopted a probabilistic approach towards this problem. First, a reliability model of the problem was established and the failure probability of induced damage was calculated. Then, the corresponding exceedance risk curve was developed indicating the relation between the failure probability and the cracked zone radius. The obtained risk curve indicated that the failure probability drops dramatically by increasing the cracked zone radius so that the probability of exceedance for any crack length greater than 4.5 m is less than 5%. Moreover, the effect of each parameter involved in the probability of failure, including blast hole radius, explosive density, detonation velocity, and tensile strength of the rock, was evaluated by using a sensitivity analysis. Finally, the impact of the decoupling ratio on the reduction of failures was investigated and the location of its maximum influence was demonstrated around the blast point.

Structural safety reliability of concrete buildings of HTR-PM in accidental double-ended break of hot gas ducts

  • Guo, Quanquan;Wang, Shaoxu;Chen, Shenggang;Sun, Yunlong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1051-1065
    • /
    • 2020
  • Safety analysis of nuclear power plant (NPP) especially in accident conditions is a basic and necessary issue for applications and commercialization of reactors. Many previous researches and development works have been conducted. However, most achievements focused on the safety reliability of primary pressure system vessels. Few literatures studied the structural safety of huge concrete structures surrounding primary pressure system, especially for the fourth generation NPP which allows existing of through cracks. In this paper, structural safety reliability of concrete structures of HTR-PM in accidental double-ended break of hot gas ducts was studied by Exceedance Probability Method. It was calculated by Monte Carlo approaches applying numerical simulations by Abaqus. Damage parameters were proposed and used to define the property of concrete, which can perfectly describe the crack state of concrete structures. Calculation results indicated that functional failure determined by deterministic safety analysis was decided by the crack resistance capability of containment buildings, whereas the bearing capacity of concrete structures possess a high safety margin. The failure probability of concrete structures during an accident of double-ended break of hot gas ducts will be 31.18%. Adding the consideration the contingency occurrence probability of the accident, probability of functional failure is sufficiently low.

Study on the flood frequency analysis for the annual exceedance series -Centering along the Geum River basin- (연초과치 계열의 홍수빈도 분석에 관한 연구 -금강유역을 중심으로-)

  • 박영근;이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.53-62
    • /
    • 1982
  • This study was attempted to find best fitted distribution and the equations for probable maximum flow with the evaluation of parameters by the method of moment for the rat- ional design of hydraulic structures in the annual exceedance series. Six subwatersheds were selected as studying basins along Geum River basin. The results obtained through this study were analyzed and summarized as follows. 1. Fitted probability distribution was showed in the order of Three Parameter Lognorm al, Type 1 Extremal, Exponential, Pearson Type III, and Log Pearson Type I distribu- tion as the results of x$^2$ goodness of fit test. 2. Kolmogorov-Smirnov test showed in the order of Three Parameter Lognormal, Exp- onential' Pearson Type III, Log Pearson Type III and Type 1 Extremal distribution for the fitted probability distribution. 3. It can be concluded that Three parameter Lognormal distribution is a best fitted one among some other distributions out of respect for each both tests. An Exponential distribution was proposed as a suitable one by Chow, V.T. showeci lower fittness than that of Three Parameter Lognormal in Geum River basin. 5. Probable flood flow equations followins the return periods for each station were obt- ained by Three Parameter Lognormal distribution. 6. It is urgently essential that best fitted probability distribution should be established for the annual exceedance series in the main river systems of Korea.

  • PDF

Analysis of the Affecting Factors to the Peak Factor in Water Supply Facilities (우리나라 상수도시설의 첨두부하 영향요소 분석)

  • Hyun, In-hwan;Lee, Che-in
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.49-58
    • /
    • 2004
  • This study is to analyze the affecting factors to the peak factor in the drinking water supply Facilities. The peak factor is a very important element to determine the capacity of the water supply facllities. Several factors such as Population served, average day water demand, ratio of domestic water use, ratio of affairs & business water use and water use per capital per day were selected as the affecting factors in this study. In this study, peak factor characteristics for Korean facilities were compared with those for Japanese ones. As a result, non-exceedance probability was suggested as the designing method for the peak factor. Also, the 50% non-exceedance probability values and the 90% values based on the 1998-1999 data were suggested in this study.

Seismic performance-based optimal design approach for structures equipped with SATMDs

  • Mohebbi, Mohtasham;Bakhshinezhad, Sina
    • Earthquakes and Structures
    • /
    • v.22 no.1
    • /
    • pp.95-107
    • /
    • 2022
  • This paper introduces a novel, rigorous, and efficient probabilistic methodology for the performance-based optimal design (PBOD) of semi-active tuned mass damper (SATMD) for seismically excited nonlinear structures. The proposed methodology is consistent with the modern performance-based earthquake engineering framework and aims to design reliable control systems. To this end, an optimization problem has been defined which considers the parameters of control systems as design variables and minimization of the probability of exceeding a targeted structural performance level during the lifetime as an objective function with a constraint on the failure probability of stroke length damage state associated with mass damper mechanism. The effectiveness of the proposed methodology is illustrated through a numerical example of performance analysis of an eight-story nonlinear shear building frame with hysteretic bilinear behavior. The SATMD with variable stiffness and damping have been designed separately with different mass ratios. Their performance has been compared with that of uncontrolled structure and the structure controlled with passive TMD in terms of probabilistic demand curves, response hazard curves, fragility curves, and exceedance probability of performance levels during the lifetime. Numerical results show the effectiveness, simplicity, and reliability of the proposed PBOD method in designing SATMD with variable stiffness and damping for the nonlinear frames where they have reduced the exceedance probability of the structure up to 49% and 44%, respectively.

Minimum Period of Data Collection for the Determination of Average Water Pressure in the Water Distribution Networks (배수구역의 평균수압결정을 위한 최소수압측정기간)

  • Hyun, In-Hwaan;DockKo, Seok;Kim, Duck-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.573-580
    • /
    • 2010
  • Average pressure in a pipe network is one of critical factors to estimate the flow distribution and to calculate UARL (Unavoidable Annual Real Losses) value in ILI (Infrastructure Leakage Index). While its collection period and measuring location are essential to obtain average pressure, their standard method have not been established so far. In this study, proper method including its procedure for data collection period and measuring point for average pressure were suggested using non-exceedance probability concept in the water distribution network.

GENERATION OF AN IMPERVIOUS MAP BY APPLYING TASSELED-CAP ENHANCEMENT USING KOMPSAT-2 IMAGE

  • Koh, Chang-Hwan;Ha, Sung-Ryong
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.378-381
    • /
    • 2008
  • The regulating and relaxing targets in the Land Use Regulation and Total Maximum Daily Loads are influenced by Land cover information. For the providing more accurate land information, this study attempted to generate an impervious surface map using KOMPSAT-2 image which a Korea manufactured high resolution satellite image. The classification progress of this study carried out by tasseled-cap spectral enhancement through each class extraction technique neither existing classification method. KOMPSAT-2 image of this study is enhanced by Soil Brightness Index(SBI), Green vegetation Index(GVI), None-Such wetness Index(NWI). Then ranges of extracted each index in enhanced image are determined. And then, Confidence Interval of classes was determined through the calculating Non-exceedance Probability. Spectral distributions of each class are changed according to changing of Control coefficient(${\alpha}$) at the calculated Non-exceedance Probability. Previously, Land cover classification map was generated based on established ranges of classes, and then, pervious and impervious surface was reclassified. Finally, impervious ratio of reclassified impervious surface map was calculated with blocks in the study area.

  • PDF

Determination of epicenters and magnitudes of future earthquakes based on the historical earthquake catalogues (역사지진 기록을 기초로한 지진규모와 위치 예측 방법)

  • 권오성;한상환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.323-330
    • /
    • 2000
  • Three historical earthquake catalogues were compared with each other in the view of frequency of events per century, cumulative magnitude distribution, and annual earthquake occurrence rate in each unit grid of 0.1°by 0.1°. And, a method to determine earthquake epicenters and magnitudes was proposed given the historical earthquake data. With this method, the epicenters and magnitudes of future earthquakes in Korean penninsula for 1,000 years were generated with each earthquake catalogue. Earthquake PGAs with 10% exceedance probability in Seoul were calculated for each catalogue and compared.

  • PDF

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.