• Title/Summary/Keyword: Exact

Search Result 8,099, Processing Time 0.058 seconds

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF

Recent Research for the Seismic Activities and Crustal Velocity Structure (국내 지진활동 및 지각구조 연구동향)

  • Kim, Sung-Kyun;Jun, Myung-Soon;Jeon, Jeong-Soo
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.369-384
    • /
    • 2006
  • Korean Peninsula, located on the southeastern part of Eurasian plate, belongs to the intraplate region. The characteristics of intraplate earthquake show the low and rare seismicity and the sparse and irregular distribution of epicenters comparing to interplate earthquake. To evaluate the exact seismic activity in intraplate region, long-term seismic data including historical earthquake data should be archived. Fortunately the long-term historical earthquake records about 2,000 years are available in Korea Peninsula. By the analysis of this historical and instrumental earthquake data, seismic activity was very high in 16-18 centuries and is more active at the Yellow sea area than East sea area. Comparing to the high seismic activity of the north-eastern China in 16-18 centuries, it is inferred that seismic activity in two regions shows close relationship. Also general trend of epicenter distribution shows the SE-NW direction. In Korea Peninsula, the first seismic station was installed at Incheon in 1905 and 5 additional seismic stations were installed till 1943. There was no seismic station from 1945 to 1962, but a World Wide Standardized Seismograph was installed at Seoul in 1963. In 1990, Korean Meteorological Adminstration(KMA) had established centralized modem seismic network in real-time, consisted of 12 stations. After that time, many institutes tried to expand their own seismic networks in Korea Peninsula. Now KMA operates 35 velocity-type seismic stations and 75 accelerometers and Korea Institute of Geoscience and Mineral Resources operates 32 and 16 stations, respectively. Korea Institute of Nuclear Safety and Korea Electric Power Research Institute operate 4 and 13 stations, consisted of velocity-type and accelerometer. In and around the Korean Peninsula, 27 intraplate earthquake mechanisms since 1936 were analyzed to understand the regional stress orientation and tectonics. These earthquakes are largest ones in this century and may represent the characteristics of earthquake in this region. Focal mechanism of these earthquakes show predominant strike-slip faulting with small amount of thrust components. The average P-axis is almost horizontal ENE-WSW. In north-eastern China, strike-slip faulting is dominant and nearly horizontal average P-axis in ENE-WSW is very similar with the Korean Peninsula. On the other hand, in the eastern part of East Sea, thrust faulting is dominant and average P-axis is horizontal with ESE-WNW. This indicate that not only the subducting Pacific Plate in east but also the indenting Indian Plate controls earthquake mechanism in the far east of the Eurasian Plate. Crustal velocity model is very important to determine the hypocenters of the local earthquakes. But the crust model in and around Korean Peninsula is not clear till now, because the sufficient seismic data could not accumulated. To solve this problem, reflection and refraction seismic survey and seismic wave analysis method were simultaneously applied to two long cross-section traversing the southern Korean Peninsula since 2002. This survey should be continuously conducted.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor (토모테라피와 선형가속기를 이용한 동일 부위의 치료 시 종양 및 정상조직의 흡수선량 평가)

  • Cheon, Geum-Seong;Kim, Chang-Uk;Kim, Hoi-Nam;Heo, Gyeong-Hun;Song, Jin-Ho;Hong, Joo-Yeong;Jeong, Jae-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.97-103
    • /
    • 2010
  • Purpose: Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. Materials and Methods: After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two differents modalities. Results: The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head & neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. Conclusion: In case of comparing both simple summation absorbed dose and integration absorbed dose, the minimum dose are represented higher as well as the maximum dose come out lower and the average dose are revealed similar with our expected values data. It is able to evaluate tumor & normal tissue absorbed dose which could had been not realized by treatment plan system. The DVH of interesting region are prescribed lower dose than expected. From now on, it needs to develop the new modality which are able to realize exact dose distribution as well as integration absorbed dose evaluation in same treatment region with different modalities.

  • PDF

The Signal Transduction Mechanisms on the Intestinal Mucosa of Rat Following Irradiation (방사선조사후 백서소장점막에서 발생하는 신호전달체계에 관한 연구)

  • Yoo Jeong Hyun;Kim Sung Sook;Lee Kyung Ja;Rhee Chung Sik
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.79-95
    • /
    • 1997
  • Purpose : Phospholipase C(PLC) isozymes play significant roles in signal transduction mechanism. $PLC-\gamma$ 1 is one of the key regulatory enzymes in signal transduction for cellular proliferation and differentiation. Ras oncoprotein, EGFR, and PKC are also known to be involved in cell growth. The exact mechanisms of these signal transduction following irradiation, however, were not clearly documented Thus, this study was Planned to determine the biological significance of PLC, ras oncoprotein, EGFR, and PKC in damage and regeneration of rat intestinal mucosa following irradiation. Material and Method : Sixty Sprague-Dawley rats were irradiated to entire body with a single dose of 8Gy. The rats were divided into S groups according to the sacrifice days after irradiation. The expression of PLC, ras oncoprotein, EGFR and PKC in each group were examined by the immunoblotting and immunohistochemistry. The histopathologic findings were observed using H&I stain, and the mitoses for the evidence of regeneration were counted using the light microscopy & PCNA kit. The Phosphoinositide(PI) hydrolyzing activity assay was also done for the indirect evaluation of $PLC-\gamma$ 1 activity. Results: In the immunohistochemistry , the expression of $PLC-{\beta}$ was negative for all grøups. The expression of $PLC-{\gamma}1$ was highest in the group III followed by group II in the proliferative zone of mucosa. The expression of $PKC-{\delta}1$ was strongly positive in group 1 followed by group II in the damaged surface epithelium. The above findings were also confirttled in the immunoblotting study. In the immunoblotting study, the expressions of $PLC-{\beta}$, $PLC-{\gamma}1$, and $PKC-{\delta}1$ were the same as the results of immunohis-tochemistry. The expression of ras oncoprctein was weakly positive in groups II, III and IV. The of EGFR was the highest in the group II, III, follwed by group IV and the expression of PKC was weakly positive in the group II and III. Conclusion: $PLC-{\gamma}1$ mediated signal transduction including ras oncoprotein, EGFR, and PKC play a significant role in mucosal regeneration after irradiation. $PLC-{\delta}1$ mediated signal transduction might have an important role in mucosal damage after irradiation. Further studies will be necessary to confirm the signal transduction mediating the $PKC-{\delta}1$.

  • PDF

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

A study on Palpation of the back-shu points (배유혈(背兪穴) 안진(按診)에 관(關)한 고찰(考察))

  • Hong, Mun-Yeup;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.155-173
    • /
    • 2000
  • The diagnosis in Oriental medicine is done by inspection, auscultation and olfaction, interrogation, four diagnostics of pulse feeling and palpation, and various system of identification like identification according to Qi(vital energy), Xue and body fluids, identification according to fair principles, identification according to principles of Wei, Qi, Ying and Xue, identification according to Sanjiao(the triple heater), identification according to four type physical constitution. Sometimes, symptoms and diagnosis techniques according to symptoms is selectively applied for the diagnosis. Among them the pulse feeling and palpation diagnosis technique using the sense of finger and palm of the hand is divided into feeling of pulse and palpation and pressing maneuver. Pressing maneuver is a diagnosis technique pressing and rubbing the affected part in order to attain data of identification including inside and outside condition of the body with regard to the nature, condition and relative seriousness of disease. There are palpation of the skin, palpation the hand and foot, palpation the chest and the abdomen, palpation shu points in pressing maneuver. The diagnosis of the Back Shu points is a technique to examine the change of disease condition from pressure ache, spontaneous ache, tension, relaxation, solidification revealed through channels and collaterals. I investigates starting disease and an attack of disease of twelve pulse and pulse condition through the study relative to the substance and technique of pressing maneuver, and adjusts diagnosis techniques of a region for acupuncture and matters to be attended. The conclusions are as follows. 1. The Shu or stream points in which pathogenic factors go are important to medical treatment of dormant diseases like bowels disease, cold symptom complex and insufficiency symptom complex. 2. Disease classified by system is diagnosed by the condition of process part like pro-trusion, cave-in, tension, relaxation, pressure ache through palpating the Shu or stream points, that is pressing upward or downward left and right sides of the backbone process by hands. 3. In real clinic pressing maneuver of one's back side is very important to patient's diagnosis treatment. Thus, pressing maneuver of one's back side have to be done without omission. 4. Diagnosis must be accomplished through the perception about the diversity of diagnosis technique of bowels disease, the exact knowledge about pressing maneuver of one's back side for enlargement of treatment range and rising of treatment rate, and pressing maneuver of the Shu or the stream points.

  • PDF