• 제목/요약/키워드: Even distribution of work

Search Result 132, Processing Time 0.025 seconds

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application (건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

Seismic performance sensitivity to concrete strength variability: a case-study

  • Stefano, M. De;Tanganelli, M.;Viti, S.
    • Earthquakes and Structures
    • /
    • v.9 no.2
    • /
    • pp.321-337
    • /
    • 2015
  • Existing building structures can easily present material mechanical properties which can largely vary even within a single structure. The current European Technical Code, Eurocode 8, does not provide specific instructions to account for high variability in mechanical properties. As a consequence of the high strength variability, at the occurrence of seismic events, the structure may evidence unexpected phenomena, like torsional effects, with larger experienced deformations and, in turn, with reduced seismic performance. This work is focused on the reduction in seismic performance due to the concrete strength variability. The analysis has been performed on a case-study, i.e., a 3D RC framed 4 storey building. A Normal distribution, compatible to a large available database, has been taken to represent the concrete strength domain. Different plan layouts, representative of realistic strength distributions, have been considered, and a statistical analysis has been performed on the induced reduction in seismic performance. The obtained results have been compared to the standard analysis as provided by Eurocode 8 for existing buildings. The comparison has shown that the Eurocode 8 provisions are not conservative for existing buildings having a large variability in concrete strength.

Investigation of flow-regime characteristics in a sloshing pool with mixed-size solid particles

  • Cheng, Songbai;Jin, Wenhui;Qin, Yitong;Zeng, Xiangchu;Wen, Junlang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.925-936
    • /
    • 2020
  • To ascertain the characteristics of pool sloshing behavior that might be encountered during a core disruptive accident of sodium-cooled fast reactors, in our earlier work several series of experiments were conducted under various scenarios including the condition with mono-sized solid particles. It is found that under the particle-bed condition, three typical flow regimes (namely the bubble-impulsion dominant regime, the transitional regime and the bed-inertia dominant regime) could be identified and a flow-regime model (base model) has been even successfully established to estimate the regime transition. In this study, aimed to further understand this behavior at more realistic particle-bed conditions, a series of simulated experiments is newly carried out using mixed-size particles. Through analyses, it is verified that for present scenario, by applying the area mean diameter, our previously-developed base model can provide the most appropriate predictive results among the various effective diameters. To predict the regime transition with a form of extension scheme, a correction factor which is based on the volume-mean diameter and the degree of convergence in particle-size distribution is suggested and validated. The conducted analyses in this work also indicate that under certain conditions, the potential separation between different particle components might exist during the sloshing process.

Development of a Multi-body Dynamics Analysis System Using the Object-Oriented Concept (객체지향 개념을 이용한 다물체 동역학 해석 시스템 개발)

  • 한형석;이재경;서종휘;송현석;박태원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.115-125
    • /
    • 2003
  • To analyze the applications of all types of mechanical systems, general purpose analysis programs have been developed and commercialized. However, it is customary to develop and use customized programs even though they sometimes require more work than a general purpose program. A customized program is simplified to adapt to a particular application from the beginning, is designed for small computers, and developed with hardware-in-the-loop in mind so it can be applied effectively. By adding design knowledge and bundling know-how to an analysis program, analysis time can be reduced. And because an analysis has to work in conjunction with other analysis programs, a proprietary program that the user can easily modify can be useful. In this thesis, a multi-body dynamics analysis system is presented using one of the most useful programming techniques, object-oriented concept. The object-oriented concept defines a problem from the physical world as an abstract object, an abstract model. The object becomes encapsulated with the data and method. Simulation is performed using the object's interface. It is then possible for the user and the developer to modify and upgrade the program without having particular knowledge of the analysis program. The method presented in this thesis has the following advantages. Since the mechanical components of the multi-body system converts independent modeling into a class, the modification, exchange, distribution, and reuse of elements are increased. It becomes easier to employ a new analysis method and interface with other S/W and H/W systems. To employ a new analysis method, there is no need to modify elements of the main solver and the Library. In addition, information can be communicated to each object through messaging. It makes the modeling of new elements easier using inheritance. When developing a S/W for the computer simulation of physical system, it is reasonable to use object-oriented modeling. Also, for multi-body dynamics analysis, it is possible to develop a solver that is user-oriented.

Comparison of the PSD radial profiles between before and after geosynchronous flux dropout: case studies using THEMIS observations

  • Hwang, Junga;Lee, Dae-Young;Kim, Kyung-Chan;Choi, Eunjin;Shin, Dae-Kyu;Kim, Jin-Hee;Cho, Jung-Hee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.122-122
    • /
    • 2012
  • Geosynchronous electron flux dropouts are most likely due to fast drift loss of the particles to the magnetopause (or equivalently, the "magnetopause shadowing effect"). A possible effect related to the drift loss is the radial diffusion of PSD due to gradient of PSD set by the drift loss effect at an outer L region. This possibly implies that the drift loss can affect the flux levels even inside the trapping boundary. We recently investigated the details of such diffusion process by solving the diffusion equation with a set of initial and boundary conditions set by the drift loss. Motivated by the simulation work, we have examined observationally the energy spectrum and pitch angle distribution near trapping boundary during the geosynchronous flux dropouts. For this work, we have first identified a list of geosynchronous flux dropout events for 2007-2010 from GOES satellite electron measurements and solar wind pressures observed by ACE satellite. We have then used the electron data from the Time History of Events and Macroscale Interactions during Substorms (THEMIS) spacecraft measurements to investigate the particle fluxes. The five THEMIS spacecraft sufficiently cover the inner magnetospheric regions near the equatorial plane and thus provide us with data of much higher spatial resolution. In this paper, we report some case studies showing energy dependence during magnetopause shadowing effect.

  • PDF

Optical Character Recognition based Security Document Image File Management System (광학문자인식 기반 보안문서 이미지 파일 관리 시스템)

  • Jeong, Pil-Seong;Cho, Yang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.7-14
    • /
    • 2019
  • With the development of information and communication technology, we have been able to access and manage documents containing corporate information anytime and anywhere using smart devices. As the work environment changes to smart work, the scope of information distribution is expanded, and more efforts are needed to manage security. This paper proposes a file sharing system that enables users who have smart devices to manage and share files through mutual cooperation. Proposed file sharing system, the user can add a partner to share files with each other when uploading files kept by spliting the part of the file and the other uses an algorithm to store on the server. After converting the file to be uploaded to base64, it splits it into encrypted files among users, and then transmits it to the server when it wants to share. It is easy to manage and control files using dedicated application to view files and has high security. Using the system developed with proposed algorithm, it is possible to build a system with high efficiency even for SMEs(small and medium-sized enterprises) that can not pay much money for security.

File Sharing Algorithm based Mutual Cooperation using Smart Device (스마트 기기를 이용한 상호 협력 기반 파일 공유 시스템)

  • Jeong, Pil-Seong;Cho, Yang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.53-60
    • /
    • 2018
  • With the development of information and communication technology, we have been able to access and manage documents containing corporate information anytime and anywhere using smart devices. As the work environment changes to smart work, the scope of information distribution is expanded, and more efforts are needed to manage security. This paper proposes a file sharing system that enables users who have smart devices to manage and share files through mutual cooperation. Proposed file sharing system, the user can add a partner to share files with each other when uploading files kept by spliting the part of the file and the other uses an algorithm to store on the server. After converting the file to be uploaded to base64, it splits it into encrypted files among users, and then transmits it to the server when it wants to share. It is easy to manage and control files using dedicated application to view files and has high security. Using the system developed with proposed algorithm, it is possible to build a system with high efficiency even for SMEs(small and medium-sized enterprises) that can not pay much money for security.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

A Study on the partial Discharge Characteristics according to the Distribution pattern of voids within LDPE (보이드 분포 형태에 따른 LDPE의 부분 방전 특성 연구)

  • Shin, Doo-Seong;Jeon, Seung-Ik;Lee, Jun-Ho;Yun, Do-Hong;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1081-1084
    • /
    • 1995
  • Internal voids located within an insulation will arise partial discharge that causes local breakdown and even the entire insulation breakdown. For HV apparatuses, it is usual case that several voids are formed within non-uniform electric field condition rather than single void within uniform field, which can be solved analitically. The purpose of this work is to study partial discharge and breakdown characteristics of an insulation according to the distribution pattern of two disc-type voids that are located within non-uniform field. The results from numerical field analysis and experiments show that the electric field within the voids decreases as they are arranged more serially, which accordingly results in the increase of partial discharge inception field(PDIF) much higher than that of single void model. With parallel arranged voids, PDIF is almost the same as that of single void model. On the other hand, AC breakdown strength decreases as voids are arranged more serially, which is a natural result considering the reduction of effective insulation thickness. For parallel voids, this effect cannot he noticed where as they show different pattern compared with single void and serial void models in $\Phi$-Q-N analysis. Considering these results may leads us to the conclusion that, in the evaluation of insulating products through PD test, it is not sufficient to determine only PDIV or existence of PD at predetermined voltage level. We could evaluate more accurately by considering all the available data such as PDIV, PD magnitude, PD occurring phase, number of PD pulses, and etc.

  • PDF