• 제목/요약/키워드: Even Harmonic

검색결과 159건 처리시간 0.023초

LCL 필터가 결합된 단상 계통연계형 인버터의 안정화를 위한 적응형 디지털 노치 필터 (An Adaptive Digital Notch Filter for Stabilization of Single-Phase Grid-Connected Inverters With LCL Filter)

  • 허진용;김학수;노의철
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.307-314
    • /
    • 2021
  • Even though the LCL filters have superior harmonic attenuation ability to L filters, stability has always been an issue. The system could be unstable because of the resonance phenomenon, especially when digital controller is used. Adding a notch filter to the compensator is one approach to solve the problem. Resonance phenomenon can be inhibited by aligning notch frequency to system resonance frequency. However, resonance frequency variation can be obtained because the actual system has a nonstationary characteristic. Therefore, the system could be unstable, where the system parameters are changed when the conventional notch filter is used. An adaptive digital notch filter that stabilizes the system even system parameters are changed. Simulation and experiment results are provided to verify the validity of the proposed adaptive filter.

저신장율 대향류확산화염에서 진동불안정성을 갖는 에지화염의 동적거동 (Dynamic Behaviors of Oscillating Edge-Flame in Low Strain Rate Counterflow Diffusion Flames)

  • 박준성;김현표;박정;김정수;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.65-72
    • /
    • 2006
  • Experiments in methane-air low strain rate counterflow diffusion flames diluted with nitrogen have been conducted to study the behavior of flame extinction and edge flame oscillation in which flame length is less than the burner diameter and thus lateral conduction heat loss in addition to radiative heat loss could be remarkable at low global strain rates. Critical mole fraction at flame extinction is examined with velocity ratio and global strain rate. Onset conditions of edge flame oscillation and flame oscillation modes are also provided with global strain rate and added nitrogen mole fraction to fuel stream (fuel Lewis number). It is seen that flame length is closely relevant to lateral heat loss, and this affects flame extinction and edge flame oscillation considerably. Edge flame oscillations in low strain rate flames are experimentally described well and are categorized into three: a growing oscillation mode, a decaying oscillation mode, and a harmonic oscillation mode. The regime of flame oscillation is also provided at low strain rate flames. Important contribution of lateral heat loss even to edge flame oscillation is clarified.

  • PDF

Synthesis and Nonlinear Optical Properties of Novel T-type Polyester Containing Thiophene with Enhanced Thermal Stability

  • No, Hyo-Jin;Cho, You-Jin;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권2호
    • /
    • pp.429-434
    • /
    • 2010
  • A novel T-type polyester 7 containing 1-(2,5-dioxyphenyl)-2-{5-(1,2,2-tricyanovinyl)-2-thienyl}ethenes as nonlinear optical (NLO) chromophores, which are part of the polymer backbone, was prepared and characterized. Polyester 7 is soluble in common organic solvents such as dimethylsulfoxide and N,N-dimethylformamide. It showed a thermal stability up to $300^{\circ}C$ in thermogravimetric analysis thermogram and the glass-transition temperature ($T_g$) obtained from differential scanning calorimetry thermogram was around $113^{\circ}C$. The second harmonic generation (SHG) coefficient ($d_{33}$) of poled polymer films at 1,560 nm fundamental wavelength was around 1.85 pm/V. The dipole alignment exhibits a greater thermal stability even at $10^{\circ}C$ higher than $T_g$, and there is no SHG decay below $125^{\circ}C$ due to the partial mainchain character of the polymer structure, which is acceptable for nonlinear optical device applications.

Sound Improvement of Violin Playing Robot Applying Auditory Feedback

  • Jo, Wonse;Yura, Jargalbaatar;Kim, Donghan
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2378-2387
    • /
    • 2017
  • Violinists learn to make better sounds by hearing and evaluating their own playing though numerous practice. This study proposes a new method of auditory feedback, which mimics this violinists' step and verifies its efficiency using experiments. Making the desired sound quality of a violin is difficult without auditory feedback even though an expert violinist plays. An algorithm for controlling a robot arm of violin playing robot is determined based on correlations with bowing speed, bowing force, and sound point that determine the sound quality of a violin. The bowing speed is estimated by the control command of the robot arm, where the bowing force and the sound point are recognized by using a two-axis load cell and a photo interrupter, respectively. To improve the sound quality of a violin playing robot, the sounds information is obtained by auditory feedback system applied Short Time Fourier Transform (STFT) to the sounds from a violin. This study suggests Gaussian-Harmonic-Quality (GHQ) uses sounds' clarity, accuracy, and harmonic structure in order to decide sound quality, objectively. Through the experiments, the auditory feedback system improved the performance quality by the robot accordingly, changing the bowing speed, bowing force, and sound point and determining the quality of robot sounds by GHQ sound quality evaluation system.

Synthesis and Properties of Novel Y-type Nonlinear Optical Polyester Containing Dioxynitroazobenzene Group with Enhanced Thermal Stability of Dipole Alignment

  • Kim, Mi-Sung;Cho, You-Jin;Song, Mi-Young;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3361-3366
    • /
    • 2011
  • New Y-type polyester (3) containing nitrophenylazoresorcinoxy groups as NLO chromophores, which are components of the polymer backbone, was prepared and characterized. Polyester 3 is soluble in common organic solvents such as N,N-dimethylformamide and acetone. It shows a thermal stability up to $240^{\circ}C$ in thermogravimetric analysis with glass-transition temperature ($T_g$) obtained from differential scanning calorimetry near $116^{\circ}C$. The second harmonic generation (SHG) coefficient ($d_{33}$) of poled polymer film at the 1064 nm fundamental wavelength is around $4.63{\times}10^{-9}$ esu. The dipole alignment exhibits a thermal stability even at $4^{\circ}C$ higher than $T_g$, and there is no SHG decay below $120^{\circ}C$ due to the partial main-chain character of polymer structure, which is acceptable for NLO device applications.

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

Dynamic responses of a beam with breathing cracks by precise integration method

  • Cui, C.C.;He, X.S.;Lu, Z.R.;Chen, Y.M.;Liu, J.K.
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.891-902
    • /
    • 2016
  • The beam structure with breathing cracks subjected to harmonic excitations was modeled by FEM based on Euler-Bernoulli theory, and a piecewise dynamical system was deduced. The precise integration method (PIM) was employed to propose an algorithm for analyzing the dynamic responses of the deduced system. This system was first divided into linear sub-systems, between which there are switching points resulted from the breathing cracks. The inhomogeneous terms due to the external excitations were tackled by introducing auxiliary variables to express the harmonic functions, hence the sub-systems are homogeneous. The PIM was then applied to solve the homogeneous sub-systems one by one. During the procedures, a predictor-corrector algorithm was presented to determine the switching points accurately. The presented method can provide solutions with an accuracy to a magnitude of $10^{-12}$ compared with exact solutions obtained by the theories of ordinary differential equations. The PIM results are much more accurate than Newmark ones with the same time step. Moreover, it is found that the PIM can maintain a high level of accuracy even when the time step increases within a relatively wide range.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

회전체에서의 균열 방위 결정 (Identification of Crack Orientation in a Simple Rotor)

  • Jun, Oh Sung;Lee, Chong-Won;Lim, Byoung Duk
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.209-214
    • /
    • 1997
  • 균열을 가진 회전축은 고조파성분이 진동에 나타나는 특징을 갖는다. 이 고조파성분을 균열탐지에 활용하기 위하여는 이들이 크게 발생되는 회전수를 이용할 필요가 있다. 2차고조파공진속도를 정의하여 이 속도에서의 균열과 불균형질량 방위각에 따른 고조파 진동 특성을 단순회전체에서 설명하였다. 이 특성을 이용하여 균열의 위치를 나타낼 수 있는 알고리즘을 만들고 수치실험을 하여 타당성을 보였다.

  • PDF

피뢰기 열화진단을 위한 저항분 누설전류의 측정장치 (Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis)

  • 길경석;한주섭;김정배
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.