• 제목/요약/키워드: Evaporation heat transfer

검색결과 273건 처리시간 0.021초

자동차용 증발기 판 내의 증발 열전달 및 유동 특성에 관한 실험적 연구 (An Experimental Study on In-Plate Evaporation Heat Transfer and Flow Characteristics for Automobile)

  • 곽경민;주상우;정우열;김택근;김광일
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.95-100
    • /
    • 2007
  • An experimental study was performed to evaluate the in-plate evaporation heat transfer and flow characteristics of a evaporator used in automobile. Two test-cores with different heat transfer area, bead-shape and bead-array were tested, A type and B type. For the heat transfer, Nusselt number for B type test-core reaches a value nearly equal to the one for A type test-core, in the whole range of equivalent Reynolds number. But, for the same mass flow rate of refrigerant, hA for B type test-core becomes higher with the increase of the mass quality of refrigerant than for A type test-core. In a flow visualization experiment, the wake zone of refrigerant circulating at u-turn position of plate is observed.

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

고온조건에서 콘크리트 부재의 온도전이 (Beat Transfer Analysis of Concrete Members under High Temperature)

  • 이태규;김혜욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1536-1541
    • /
    • 2009
  • When water inside the concrete member evaporates by high temperature, the evaporation heat which absorbs surrounding temperature occurs. The rate of increment of the internal temperature in concrete is reduced due to the evaporation heat in spite of continuously increasing external temperature. In this paper, the prediction method of internal temperature of high strength concrete members considering the evaporation heat under the high temperature is presented. Finite element method is employed to facilitate thermal analysis for any position of member. And the thermal characteristics models of high strength concrete affected by high temperature are proposed. To demonstrate the validity of this numerical procedure, the prediction by the proposed algorithm is compared with the test results of other researchers. The proposed algorithm shows a good agreement with the experimental results including the phenomenon that temperature is lost by the evaporation heat.

  • PDF

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF

R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구 (A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant)

  • 정규하;박윤철;오상경
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구 (Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes)

  • 최인수;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제10권2호
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF

내경 4.57mm 관내 CO2의 증발 열전달 특성 (Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.574-579
    • /
    • 2008
  • 수평관내 $CO_2$의 증발 열전달 계수를 실험적으로 조사하였다. 냉매 순환루프의 주요 구성품은 수액기, 변속냉매 펌프, 질량 유량계, 예열기, 증발기(시험부)로 구성된다. 시험부는 내경 4.57 mm의 수평 평활 스텐레스관이다. 실험은 질량유속 $400{\sim}900kg/m^2s$, 포화온도 $5{\sim}20^{\circ}C$, 열유속 $10{\sim}40kW/m^2$인 조건에서 수행하였다. 실험결과로부터 $CO_2$의 열전달은 대류비등보다는 핵비등에 더 많은 영향을 받는 것을 알 수 있었고, $CO_2$의 질량유속은 핵비등에 많은 영향을 미치지 않는 것으로 나타났다. 실험결과와 종래의 상관식을 비교해 본 결과, 기존의 상관식은 실험데이터를 과소예측하였지만, 정 등의 상관식은 좋은 일치를 보였다. 따라서, 수평관내 $CO_2$의 증발 열전달 계수를 예측할 수 있는 정확한 상관식의 개발이 필요하리라 판단된다.

LNG 냉열활용을 위한 초저온 열교환시스템의 축소모형에서 증발 열전달 특성 (Characteristics of Evaporation Heat Transfer in a Small-Scale Cryogenic Heat Exchange System for the Utilization of LNG Cold Energy)

  • 남상철;이상천;이용원;손영순
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.25-33
    • /
    • 1998
  • 본 연구는 LNG냉열활용을 위해 초저온 열교환시스템을 제작하고 액화질소와 에틸렌-글리콜 수용액을 작동유체로 사용하여 증발 열전달 특성실험을 수행하였다. 초저온 열교환기는 2중관식 열교환기이며, 내부관 지름이 8, 15 mm이며 길이는 6m이다. wire-coil inserts를 사용하여 열전달촉진 성능평가를 수행하였다. 액화질소와 에틸렌-글리콜 수용액의 출입구 온도, 벽면온도, 유량, 압력을 측정하였고, 이를 증발 열전달계수와 누셀트수를 계산하는데 사용하였다. 열전달상관식을 누셀트수, 프란틀수와 등가레이놀즈수의 멱법칙관계로 제안하였고, 그 결과 열전달촉진관이 평활관보다 2.5 ${\~}$ 5.5배정도 열전달이 증가되었다. 이 상관식을 이용하여 LNG냉열이용을 위한 초저온 2중관 열교환기를 설계하였고, 그 결과로 제시하였다.

  • PDF

고온 표면에 부착된 증발 액적에 의한 열유속 변화 추정 (The Evaluation of Heat Flux by Evaporating Droplet on the Hot Surface)

  • 신운철;배신철
    • 대한기계학회논문집B
    • /
    • 제31권9호
    • /
    • pp.764-771
    • /
    • 2007
  • The objective of the present work is to evaluate the evaporation heat flux of deposited droplet on the hot surface by using of inverse heat transfer technique. On the basis of measured temperature, a integral form solution is determined for the transient temperatures beyond the two positions by using Green's function technique. This method first approximates the temperature data with a half polynomial series of time. we compared this result with constant radius model in single phase regime, nucleate boiling regime, film boiling regime respectively. this paper performed the experiments as following conditions: (a)the surface temperature is within the range between $80^{\circ}C\;and\;160^{\circ}C$ in the conduction, (b) droplet diameter are 2.4 and 3.0mm. (c) surface roughness is $0.18{\mu}m$.

Simulation of transport phenomena in porous membrane evaporators using computational fluid dynamics

  • Mohammadi, Mehrnoush;Marjani, Azam;Asadollahzadeh, Mehdi;Hemmati, Alireza;Kazemi, Seyyed Masoud
    • Membrane and Water Treatment
    • /
    • 제7권2호
    • /
    • pp.87-100
    • /
    • 2016
  • A numerical simulation of membrane evaporation process was carried out in this work. The aim of simulation is to describe transport of water through porous membranes applicable to the concentration of aqueous solutions. A three-dimensional mathematical model was developed which considers transport phenomena including mass, heat, and momentum transfer in membrane evaporation process. The equations of model were then solved numerically using finite element method. The results of simulation in terms of evaporation flux were compared with experimental data, and confirmed the accuracy of model. Moreover, profile of pressure, concentration, and heat flux were obtained and analyzed. The results revealed that developed 3D model is capable of predicting performance of membrane evaporators in concentration of aqueous solutions.