• 제목/요약/키워드: Evaporation efficiency

검색결과 428건 처리시간 0.035초

서브마이크론 입자 측정용 저압 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Low Pressure Impactor for Sampling Submicron Aerosols)

  • 지준호;조명훈;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.349-358
    • /
    • 2004
  • A low pressure impactor is an impaction device to separate airborne particles into aerodynamic size classes at low pressure condition. We designed a two-stage low-pressure impactor to classify submicron sized environmental aerosols. Performance evaluation was carried out for stages 1 and 2 by using an electrical method. Monodisperse liquid dioctyl sebacate (DOS) particles were generated using evaporation-condensation process followed by electrostatic classification using a DMA (differential mobility analyzer). The test particles were in the range of 0.08∼0.8$\mu\textrm{m}$. For the evaluation of the impactor we used two electrometers; one was connected to the impaction plate of the impactor and the other was to the Faraday cage used as a backup filter. The effect of polydispersity of test aerosols on the performance was investigated. The results showed that the experimental 50-% cutoff diameters at each impactor's operation pressure were 0.53 and 0.187$\mu\textrm{m}$ for stages 1 and stage 2, respectively. The effects of operation pressure on the cutoff diameter and the steepness of collection efficiency curves were also investigated.

MAT사이클을 이용한 분리축 가스터빈 엔진의 성능향상에 관한 연구 (Performance Improvement of Free Power Gas Turbine Type Gas Turbine Engine by Using of a MAT Cycle)

  • 공창덕;김경두
    • 한국추진공학회지
    • /
    • 제5권2호
    • /
    • pp.65-72
    • /
    • 2001
  • 본 연구에서 MAT(Moisture Air Turbine) 사이클은 압축기 입구에 미세한 액적을 분무함에 따라, 가스터빈 엔진의 성능을 향상시킬 수 있음을 제시하였다. 혼합물이 상변화하는 동안의 압축기 일은 이론적으로 등 엔트로피 압축 일로 고려하였다. 상변화 과정에서 증발잠열의 영향으로 압축기 일은 감소함을 알 수 있다. 성능해석 프로그램을 이용해서 1000, 1210, 1350 rps 조건에서, 압축기 유입공 기에 대한 1.0%의 물을 분무했을 경우, 각각 16.2%, 14.9%, 12.6%의 출력이 증가함을 확인하였다. 또한 압축기 일의 감소에 의해 열 효율도 증가함을 확인하였다.

  • PDF

Simvastatin loaded porous poly(lactide-co-glycolide)(PLGA) microspheres as delivery systems strategies for injuring tissue and invitro study

  • Bao, Trinh-Quang;Kim, Yang-Hee;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.38.2-38.2
    • /
    • 2009
  • Regeration of natural tissuesor to create biological substitutes for defective or lost tissues and organs through the use of cells. In addition to cells and their porous, drugs are required to promote tissue regeneration. Therefore, the present studies were prepared using simvastatim loaded porous poly(lactide-co-glycolide) (PLGA) by double emulsion solvent evaporation water-in-oil-in-water technique (W/O/W) as drug delivery system strategies for injuring tissue. The resulting microspheres were evaluated for morphology, particle size, encapsulation efficiency, degradation of PLGA microspheres in vitro drug release and in vitro cell viability. Scanning electronic microscopic (SEM) showed that the porosities of the particles was changed by experimental conditions and cultured cells were attached well on porous microspheres surface. The X-ray diffraction (XRD) and differential scanning calometry (DSC) analysis indicate thatsimvastatim was highly dipersed in the microsphere at amorphousstate.

  • PDF

直接噴射式 디이젤機關의 燃燒室形狀과 火焰의 發達 (The effect of air and spray turbulence in a D.I. diesel engine on the flame progress)

  • 방중철;태전간랑
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.44-52
    • /
    • 1987
  • 본 논문에서는 앞서의 연구들에서 얻은 연구성과를 실제의 디이젤기관에 적용 시켜 화염의 발달상태와 기관속도의 상승 등을 고찰하여, 그 유효성을 평가했다. 또 고온공기류덕트에서는 실험하기가 곤란했던, 분무자체에 족회운동을 일으킨 경우의 연 소과정에 대해서도 피스톤요부의 벽면에 충돌하는 분무의 각도를 변화시켜, 고속도 화 염사진으로 부터 검토했다.

ESTIMATION OF LONG-TERM POLLUTANT REMOVAL EFFICIENCIES OF WET RETENTION/DETENTION BASINS USING THE WEANES MODEL

  • Youn, Chi-Hyueon;Pandit, Ashok;Cho, Han-Bum
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.215-219
    • /
    • 2005
  • A macro spreadsheet model, WEANES (Wet Pond Annual Efficiency Simulation Model), has been developed to predict the long-term or annual removal efficiencies of wet retention/detention basins. The model uses historical, site-specific, multi-year, rainfall data, usually available from a nearby National Oceanic and Atmospheric Administration (NOAA) climatological station to estimate basin efficiencies which are calculated based on annual mass loads. Other required input parameters are: 1) watershed parameters; drainage area, pervious curve number, directly connected impervious area, and ti me of concentration, 2) pond parameters; control and overflow elevations, pond side slopes, surface areas at control elevation and pond bottom; 3) outlet structure parameters; 4) pollutant event mean concentrations; and 5) pond loss rate which is defined as the net loss due to evaporation, infiltration and water reuse. The model offers default options for parameters such as pollutant event mean concentrations and pond loss rate. The model can serve as a design, planning, and permitting tool for consulting engineers, planners and government regulators.

  • PDF

유기 광기전 소자의 전기적 특성에 미치는 산소 플라즈마 처리의 영향 (Effects of $O_2$ Plasma Treatment on the Electrical Properties of Organic Photovoltaic Cell)

  • 오동훈;이영상;박희두;신종열;김태완;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1463-1464
    • /
    • 2011
  • An indium thin oxide(ITO) is used as a substrate material for organic light-emitting diodes(OLEDs) and organic photovoltaic cells. This study examined the effects of an $O_2$ plasma treatment on the electrical properties of an organic photovoltaic cell. The four probe method and Atomic force microscope(AFM) revealed the lowest surface resistance at the plasma treatment intensity of 250 [W] and the lowest average surface roughness of 2.0 [nm] at 250 [W]. The lowest average resistance of 17 [${\Omega}$/sq] was also observed at 250 [W] 40 [sec]. The $O_2$ plasma treatment device and a basic device in a structure of CuPc/C60/BCP/Al on ITO glass were fabricated by thermal evaporation, respectively. When the $O_2$ plasma treatment was used to the ITO, The experimental results revealed that the power conversion efficiency(PCE) indicated 65 [%] higher in the PCE than that without the plasma treatment.

  • PDF

Q.C.M.을 이용한 메로시아닌 색소 LB막의 광학적 특성 분석 (Analysis of Optical Properties of Merocyanine Dye LB Films by Using Q.C.M.)

  • 강기호;김정명;신훈규;장정수;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.130-133
    • /
    • 2000
  • The optical characteristics of merocyanine dyes have been investigated widely due to their possible application to the high efficiency photo-electric devices. The optical systems are mostly fabricated using vacuum evaporation. casting and Langmuir-Blodgett method and the arrangement and orientation of dye molecules is one of the most important factors in the study on the optical characteristics. In this study. we fabricated the molecular systems through the LB techniques and investigated the optical characteristics of merocyanine dye LB film using the oscillation characteristics of quartz crystal. It was quite interesting behavior that the resistance and frequency shift at the parallel resonance under the UV irradiation.

  • PDF

밀폐형 2상 열사이폰의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Two-phase closed Thermosyphon)

  • 조기현;백이;정형길
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.165-171
    • /
    • 2002
  • The thermosyphon has been used as a heat transmission device in the heat recovery of low level energy and cooling for heat generating equipments. Many studies on the working fluids and wicks have been reported to improve the heat transfer efficiency of the thermosyphon. A low temperature heat pipe with acetone is chosen in the present study to compare the heat transfer characteristics due to pouring amount of working fluid, magnitude of power supplied and tilt angles. The thermosyphon made ⵁ$15.88{\times}0.8t{\times}600mm$ of copper, evaporation section 200mm, insulation section 25mm, condensation 375mm. Heat transfer rate of the thermosyphon increase as magnitude of power supplied increase and observe dry out phenomenon at 5~10% of pouring amount of working fluid. So thermosyphon at the 150kJ/s judged to need 12% or more. Heat transfer rate of the thermosyphon have nothing to do with tilt angles. Dry out phenomenon of the thermo syphon makes it possible that a low temperature thermosyphon may be used to control temperature and heat transfer of a system when the critical quantity of a working fluid is supplied in the thermosyphon.

  • PDF

입자의 실시간 관측이 가능한 임팩터의 설계 및 성능해석 (Real -time Observation on Airborne Particles with Visual Impactor)

  • 육세진;안강호
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.67-76
    • /
    • 2003
  • Recently consideration of health and interest on bio aerosols have been growing steadily. In this study, inertial impactor, which can be used to collect airborne particles and bio aerosols, was newly devised for real-time observation on the particles collected on impaction plate. and named Visual Impactor. Flow field and particle trajectory in the space between nozzle and impaction plate was analyzed numerically, and the collection effciencies were calculated. Calibration and performance evaluation of the Visual Impactor was conducted with polydisperse aerosols generated from 0.1% sodium chloride solution. Cut-off diameter from numerical simulation was in good agreement with that from experimental results. Because of particle bounce and particle deposition on nozzle tip due to short jet-to-plate distance, the collection efficiencies from numerical and experimental analyses were different slightly. Visual Impactor was used to collect airborne particles, and the features of collected particles could be seen in real-time. Airborne particles in different weather conditions (fine, cloudy, and rainy) were sampled and compared one another The features of collected airborne particles were dependent strongly upon relative humidity. In addition, with hours elapsing, shapes and colors of collected particles were changed by evaporation and surface tension, etc.

가솔린기관의 냉시동시 Glow Plug를 이용한 배기가스저감에 관한 실험적 연구 (An Experimental Study on the Reduction of Exhaust Emissions by using Glow Plug during Cold-start and Warm-up in Gasoline Engine)

  • 문영호;김종호;오영택
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.7-14
    • /
    • 2002
  • In order to reduce exhaust omissions of spark ignition engine, it is important not only to improve catalyst conversion efficiency but also to directly reduce engine out exhaust emissions, during cold starting and warm up process. Therefore many researchers have been attracted to develop an early fuel evaporator(EFE) by Introducing a ceramic heater fur a solution of engine out exhaust emissions in SI engine. But, the performance of the EFE in MPI engine to reduce the exhaust emissions and to improve the cold startability has not been clarified yet. The purpose of this study is to evaluate the feasibility of a glow plug far EFE. Impinging spray using heated and unheated glow plug helps the vaporization of the fuel and heat up the three way catalyst sufficiently. The amount of CO, and UHC is reduced overall. The amount of NOx is higher at the initial stage, but become lower as time goes on than without glow plug.