• 제목/요약/키워드: Evaporated liquid mass

검색결과 20건 처리시간 0.022초

흡기관내 와류생성기가 압축착화엔진의 수분 농도 분포 및 연소성능 향상에 미치는 영향 (Effect of Vortex Generator in Intake Pipe on the Moisture Concentration Distributions and Combustion Performance in a CI Engine)

  • 정석훈;서현규
    • 한국분무공학회지
    • /
    • 제23권4호
    • /
    • pp.169-174
    • /
    • 2018
  • In this work, optimization of blade shape for the improvement of mixture formation and vortex of intake port was performed by numerically, and the combustion performance of CI engine with optimized blade shape was investigated. To achieve this, 3 types of blade shape were studied under the different air flow mass conditions and the numerical results were investigated in terms of humidification water, moisture concentration, and velocity distributions. Evaporated liquid mass was also compared under various test conditions to reveal the turbulent intensity in an intake port. It was observed that the optimized blade shape can improve the humidification water, moisture concentration, and velocity distributions of intake port inside. The evaporated liquid mass was also increased under the conditions with blade. Especially, low NOx emissions was observed with optimized blade condition.

High throughput automated 96-well solid-phase extraction and liquid chromatography-tandem mass spectrometric analysis of beraprost in human plasma

  • Chang, Kyu-Young;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.224.1-224.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the determination of beraprost in human plasma. Plasma samples were transferred into 96-well OASIS HLB extraction plate using an automated sample handling system and the drugs were eluted with methanol. The eluents were then evaporated and reconstituted with water. All sample transfer and solid-phase extraction (SPE) was automated through the application of both the PerkinElmer MultiPROBE II HT and TOMTEC Quadra 96 workstation. (omitted)

  • PDF

Polygala japonica houttuyn의 성분연구 (Studies on the constiuents of polygala japonica houttuyn)

  • 우린근;김제훈
    • 약학회지
    • /
    • 제1권1호
    • /
    • pp.1-2
    • /
    • 1948
  • The finely powdered entire harbs of Polygala japonica Houttuyn, a drug known as Yong Shin-Cho in Korea, were boiled with methanol and from the filtered extract the methanol was distilled off under diminished pressure and the aqueous solution of the residue was evaporated to dryness after being mixed with ignited magnesia. The dried mass was boiled with absolute alcohol, the filtered clear liquid was evaporated to a small volume and the precipitate Saponin produced by mixing with ether was filtered off. When the filtrate was again evaporated to the thickness of a syrup and allowed to cool for a few days in an ice box, crystalls were separated out in about 5% yield, which formed colorless columns, M. P. 142.deg., from methanol and had the formula $C_{6}$ $H_{12}$ $O_{5}$. On heating it with acetic acid anhybride and sodium acetate, its tetraacetyl derivative $C_{6}$ $H_{8}$ $O_{5}$(C $H_{3}$CO)$_{4}$ was obtained and which formed colorless needles, M. P. 62-5.deg., from ethanol. Their melting points, results of elementar analysis and other characteristics agreed with that of Polygalitol and its derivative. Finally they were proved to be identical with Polygalitol and its derivative, respectively, through determination of mixed melting points with the samples. Polygalitol was isolated from several plants of genus polugala e. g. P. amara, P. vulgaris, P. teunifolia, P. senega etc. The authors added to them another instance of identifying Polygalitol from the plant of genus polygala.olygala.

  • PDF

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권1호
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Multi-class, Multi-residue Analysis of 59 Veterinary Drugs in Livestock Products for Screening and Quantification Using Liquid Chromatography-tandem Mass Spectrometry

  • Yu Ra Kim;Sun Young Park;Tae Ho Lee;Ji Young Kim;Jang-Duck Choi;Guiim Moon
    • 한국환경농학회지
    • /
    • 제41권4호
    • /
    • pp.288-309
    • /
    • 2022
  • BACKGROUND: The objective of this study was to develop a comprehensive and simple method for the simultaneous determination of 59 veterinary drug residues in livestock products for safety management. METHODS AND RESULTS: For sample preparation, we used a modified liquid extraction method, according to which the sample was extracted with 80% acetonitrile followed by incubation at -20℃ for 30 min. After centrifugation, an aliquot of the extract was evaporated to dryness at 40℃ and analyzed using liquid chromatography combined with tandem mass spectrometry. The method was validated at three concentration levels for beef, pork, chicken, egg, and milk in accordance with the Codex Alimentarius Commission/Guidelines 71-2009. Quantitative analysis was performed using a matrix-matched calibration. As a results, at least 52 (77.6%) out of 66 compounds showed the proper method validation results in terms of both recovery of the target compound and coefficient of variation required by Codex guidelines in livestock products. The limit of quantitation of the method ranged from 0.2 to 1119.6 ng g-1 for all matrices. CONCLUSION(S): This method was accurate, effective, and comprehensive for 59 veterinary drugs determination in livestock products, and can be used to investigate veterinary drugs from different chemical families for safety management in livestock products.

Preparation of Porous Nanostructures Controlled by Electrospray

  • Nguyen, Dung The;Nah, In Wook;Kim, Kyo-Seon
    • Korean Chemical Engineering Research
    • /
    • 제53권5호
    • /
    • pp.627-631
    • /
    • 2015
  • Various solid structures were prepared by electrospray technique. In this process, liquid flows out from a capillary nozzle under a high electrical potential and is subjected to an electric field, which causes elongation of the meniscus to form a jet. In our study, by controlling the amount of polyvinyl pyrrolydone in precursor solution, the jet either disrupted into droplets for the formation of spherical particles or was stretched in the electric field for the formation of fibers. During the electrospray process, the ethanol solvent was evaporated and induced the solidification of precursors, forming solid particles. The evaporation of ethanol solvent also enhanced the mass transport of solutes from the inner core to the solid shell, which facilitated fabrication of porous and hollow structure. The network structures were also prepared by heating the collector.

액체크로마토그래피-사중극 비행시간형 탠덤질량분석기를 이용한 Bacillus mojavensis 균주 속 사이드로포어 규명 (Determination of Siderophore from Bacillus Mojavensis Using Liquid Chromatography quadrupole Time-of-flight Tandem Mass Spectrometry)

  • 천해인;여미선;김강민;강재선;표재성
    • 생명과학회지
    • /
    • 제29권2호
    • /
    • pp.198-201
    • /
    • 2019
  • Bacillus mojavensis를 이용한 항진균성 및 식물 생장 촉진 활성이 최근 보고되었다. 이런 활성은 사이드로포어의 일반적 특성과 일치하여, 본 연구에서는 Bacillus mojavensis가 생산하는 사이드로포어를 고체상추출 카트리지와 액체크로마토그래피-사중극 비행시간형 탠덤 질량분석기를 이용하여 규명하였다. Bacillus mojavensis를 페놀 배지에서 16시간 동안 배양하고 동결 건조 시킨 후, 물에 용해시켜 고상추출 카트리지에 로딩하였다. 카트리지는 5% 메탄올로 세척하고 2% 포름산을 이용해 용출 시켰다. 용출액은 메탄올에 재용해 후 분석을 하였다. Bacillus mojavensis의 사이드로포어는 질량 스펙트럼의 결과를 바탕으로 882.2556의 분자량을 갖는 카테콜타입의 사이드로포어 중 하나인 bacillibactin으로 확인되었다. 이 사이드로포어 분석은 Bacillus 연구 및 기능성 식품 그리고 Bacillus mojavensis의 약학 응용 분야에 큰 기여를 할 것으로 예상된다.

Simultaneous Characterization of Sofalcone and Its Metabolite in Human Plasma by Liquid Chromatography -Tandem Mass Spectrometry

  • Han, Sang-Beom;Jang, Moon-Sun;Lee, Hee-Joo;Lee, Ye-Rie;Yu, Chong-Woo;Lee, Kyung-Ryul;Kim, Ho-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권5호
    • /
    • pp.729-734
    • /
    • 2005
  • A sensitive and selective method for quantitation of sofalcone and its active metabolite in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Plasma samples were transferred into 96-well plate using an automated sample handling system and spiked with 10 $\mu$L of 2 $\mu$g/mL $d_3$-sofalcone and $d_3$-sofalcone metabolite solutions (internal standard), respectively. After adding 0.5 mL of acetonitrile to the 96-well plate, the plasma samples were then vortexed for 30 sec. After centrifugation, the supernatant was transferred into another 96-well plate and completely evaporated at 40 ${^{\circ}C}$ under a stream of nitrogen. Dry residues were reconstituted with mobile phase and were injected into a $C_{18}$ reversed-phase column. The limit of quantitation of sofalcone and its metabolite was 2 ng/mL, using a sample volume of 0.2 mL for analysis. The reproducibility of the method was evaluated by analyzing 10 replicates over the concentration range of 2 ng/mL to 1000 ng/mL. The validation experiments of the method have shown that the assay has good precision and accuracy. Sofalcone and its metabolite produced a protonated precursor ion ([M+H]$^+$) of m/z 451 and 453, and a corresponding product ion of m/z 315 and 317, respectively. Internal standard ($d_3$-sofalcone and $d_3$-sofalcone metabolite) produced a protonated precursor ion ([M+H]$^+$) of m/z 454 and 456 and a corresponding product ion of m/z 315 and 317, respectively. The method has been successfully applied to a pharmacokinetic study of sofalcone and its active metabolite in human plasma.

LC-MS/MS를 이용한 비글견 혈장 중 파록세틴의 고감도 분석 (Sensitive determination of paroxetine in canine plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS))

  • 장규영;강승우;한상범;염정록;이경률;이희주
    • 분석과학
    • /
    • 제20권2호
    • /
    • pp.138-146
    • /
    • 2007
  • 본 연구에서는 비글견 혈장 중의 파록세틴을 액체상추출법(LLE)으로 전처리하고 액체크로마토그래피-탠덤질량분석기(LC-MS/MS)로 신속하게 분석하는 방법을 개발하였다. 파록세틴과 내부표준물질로 사용한 플루오세틴을 TBME(tert-butyl methyl ether)로 추출하고 상층액을 취하여 건조시킨 후, 이동상 $100{\mu}L$로 재분산하여 LC-MS/MS에 주입하였다. HPLC 분석조건으로 Capcell Pak UG120($2.0{\times}150mm$, $5{\mu}m$) 컬럼을 사용하였으며, 이동상은 50% 아세토니트릴(pH 3, formic acid로 조정) 용액을 사용하였고, 유량은 0.2 mL/min으로 하였다. MS/MS의 SRM(selective reaction monitoring) 방법으로 파록세틴과 플루오세틴의 선구 이온, 생성 이온을 각각 m/z $330{\rightarrow}192$, m/z $310{\rightarrow}148$로 분석한 결과 0.02~5 ng/mL의 농도범위에서 상관계수($R^2$) 0.9993으로 좋은 직선성을 나타내었다. 또한 정량한계는 0.02 ng/mL이며, 정밀성은 일내 및 일간 변동계수가 7.67% 이하이고, 정확도는 92.96~102.99%로 비글견 혈장 중의 파록세틴의 약물동력학 연구에 이용될 수 있는 충분한 감도와 특이성, 직선성, 정밀성 및 정확성을 갖고 있음을 확인하였다.

새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발 (Development of induction heating superheater system using new heat exchanging method)

  • 설용태;이의용;권혁민
    • 한국산학기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.740-746
    • /
    • 2009
  • 본 논문에서는 공진형 유도가열기를 이용한 2단 직렬 부하형 유도가열 과열증기 발생장치를 제안하였다. 발열방식은 외부의 가열코일로부터 특수 합금 발열체에 비접촉 상태로 전자유도 와전류를 구조체에 흐르게 하였다. 인버터는 풀-브리지 고주파 직렬 부하 공진형 이며, LC 공진 설계에서 부하자체를 인덕터로 선정하여 효율을 최대화 하였다. 개발된 장치는 전자유도가열 발열체와 유체이동에 의한 새로운 열교환 방식으로 일체의 연소과정 없이 기체, 액체 및 증발체 등을 상온에서 고온에 이르기까지 고정도의 가열이 가능하다.