• Title/Summary/Keyword: Evaluation study

Search Result 48,481, Processing Time 0.082 seconds

Contents analyses of teaching·learning research on housing education of home economics for secondary schools (중등학교 주생활교육 교수·학습 개발연구 내용분석)

  • Joo, Hyunjung;Cho, Jaesoon;Choi, Yoori
    • Journal of Korean Home Economics Education Association
    • /
    • v.29 no.3
    • /
    • pp.33-48
    • /
    • 2017
  • The purpose of this research was to analyze the contents of housing teaching learning studies in Home Economics of secondary schools since 2001. The 22 research, drawn from the database 'riss4u', were analyzed in terms of general information of the paper (studied institution & year, implementation & evaluation, subject of study & size) and specific contents of teaching learning plans (theme, curricula & textbooks, methode & # of lessons, resources). The results showed that most studies were reported during the 7th or the 2007 revised curricula period. All, except one doctoral dissertation, were master's theses from a few universities. In all studies, ranging from 2 to 15 lessons, teaching learning plans were implemented and evaluated in the class of the researcher while some were applied in other schools, too. The theme of the teaching learning plans varied but were concentrated on one out of two content elements and two out of six learning elements. The 2007 revised curriculum seems to be an important turning point, not only reinforcing the analyses of the curricular and textbooks in the analyzing stage but also facilitating the use of various methods for the lessons in the developing stage. Practical problem based model was the most frequently adopted, while cooperative learning and ICT served as fundamental although not always mentioned. Various teaching resources such as UCC, reading materials, PPT were developed for the teacher. Activity sheets were the most frequently used for the students, followed by reading materials. Because teaching learning is an essential core of education, teaching learning studies should be more actively conducted and the variety of subject topics, methods and resources should also be obtained by more researchers.

The Effect of Percutaneous Bilateral Metalic Stent for Hilar Cholangiocarcinoma (간문부 담관암 환자에서 경피경관 양측성 금속 배액관의 효과)

  • Kim, Kum-Rae;Kim, Joo-Hyung;Park, Won-Kyu;Jang, Jay-Chun;Cho, Jae-Ho;Kim, Tae-Nyen;Kim, Jun-Hwan;Jang, Byeng-Ik
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.211-220
    • /
    • 2005
  • Background: The purpose of this study was to determine the effectiveness of a percutaneously placed self-expanding metallic stent for the relief of biliary obstruction in patients with hilar cholangiocarcinoma. Materials and Methods: From November 2001 to December 2004, 48 patients with hilar cholangiocarcinoma were prospectively studied. After percutaneous placement of bilateral selfexpanding, uncovered metallic stents, follow-up evaluation was carried out until July 2005. Results: There were 4 cases of Bismuth type II, 21 cases of Bismuth type IIIa, 8 cases of Bismuth type IIIb and 15 cases of Bismuth type IV. Stent placement was technically successful in all patients. All patients had satisfactory biliary drainage, resulting in one week drainage rate of 72.8% and final drainage rate of 91.1%. There were 12 cases (21.3%) of abdominal pain requiring analgesics and 1 case (7.1%) of cholangitis; both were successfully managed with conservative treatments. Late complications occurred in four patient (8.3%), including two patients with cholangitis, one patient with liver abscess, and one patient with biloma; all were appropriately managed by percutaneous drainage. The average length and median durations of stent patency and median survival time were 303 days (range, 60~815) and 338 days (range, 60~1175), respectively. Conclusion: Placement of a percutaneous metallic stent is an effective and safe method for palliation of patients with hilar cholangiocarcinoma.

  • PDF

A Study on the Evaluation of Distribution Stability of Refrigerated Rice Cake Using Natural Antibiotics (천연항균제를 사용한 냉장떡류의 유통 안정성 평가연구)

  • Yoo, Seung Jin;Chin, Jong-eon;Oh, Sung Hoon;Ryu, Min Jung;Hwang, Kwontack
    • Journal of Chitin and Chitosan
    • /
    • v.23 no.4
    • /
    • pp.244-255
    • /
    • 2018
  • Natural extract in liquid phase was adjusted to 0, 0.25, 0.5, 1, 2, and 4% concentration to check microbial changes and to measure 4, 8, $12^{\circ}C$ for refrigeration temperature. In the case of grapefruit extract, the microbial safety was maintained at all the concentrations at $4^{\circ}C$ storage, but the antimicrobial activity was maintained at $12^{\circ}C$ storage and at $8^{\circ}C$ and 21 days storage. In the case of grape seed extract, only the 4% of the culture at $8^{\circ}C$ satisfied the requirement of safety of food distribution for the last 21 days, and the safety criterion was satisfied only at 4% concentration at $12^{\circ}C$ for 18 days. Complex Scutellaria baicalensis extract showed the total number of microbial cells treated by concentration. It was confirmed that microbial flow safety was maintained at low temperature ($4^{\circ}C$). However, at $8^{\circ}C$ and $12^{\circ}C$, Exceeded the distribution limit. When polylysine was applied to brown rice cake, it showed activity in all groups except $4^{\circ}C$, but these properties were not observed at $8^{\circ}C$ and $12^{\circ}C$. At a concentration of 0.5% or more of chitosan, the growth of the microorganism is suppressed by the 21st day very stably, and a similar tendency is observed at 8 and $12^{\circ}C$, so that it may be an antimicrobial material that inhibits microorganisms. At the first day, the distribution standards for general bacterial counts were exceeded.Ethyl-pyruvate showed that microorganism safety was maintained at $4^{\circ}C$ and 1% concentration, and food safety was stable even at 2 or 4%. Glycine showed very good and stable distribution stability at $4^{\circ}C$. However, at $8^{\circ}C$ and $12^{\circ}C$, the shelf life of 14 days could not be maintained as with the addition of other antimicrobial active substances.

Evaluation of IH-1000 for Automated ABO-Rh Typing and Irregular Antibody Screening (ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가)

  • Park, Youngchun;Lim, Jinsook;Ko, Younghuyn;Kwon, Kyechul;Koo, Sunhoe;Kim, Jimyung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.127-135
    • /
    • 2012
  • Background: Despite modern advances in laboratory automated medicine, work-process in the blood bank is still handled manually. Several automated immunohematological instruments have been developed and are available in the market. The IH-1000 (Bio-Rad Laboratories, Hercules, CA, USA), a fully automated instrument for immunohematology, was recently introduced. In this study, we evaluated the performance of the IH-1000 for ABO/Rh typing and irregular antibody screening. Methods: In October 2011, a total of 373 blood samples for ABO/Rh typing and 303 cases for unexpected antibody screening were collected. The IH-1000 was compared to the manual tube and slide methods for ABO/Rh typing and to the microcolumn agglutination method (DiaMed-ID system) for antibody screening. Results: For ABO/Rh typing, concordance rate was 100%. For unexpected antibody screening, positive results for both column agglutination and IH-1000 were observed in 10 cases (four cases of anti-E and c, three of anti-E, one of anti-D, one of anti-M, and one of anti-Xg) and negative results for both were observed in 289 cases. The concordance rate between IH-1000 and column agglutination was 98.7%. Sensitivity and specificity were 90.9% and 99.3%, respectively. Conclusion: The automated IH-1000 showed good correlation with the manual tube and slide methods and the microcolumn agglutination method for ABO-RhD typing and irregular antibody screening. The IH-1000 can be used for routine pre-transfusion testing in the blood bank.

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Development and Preliminary Evaluation of a Leukocyte Removal Aptamer Filter (압타머를 이용한 백혈구제거필터의 개발 및 예비평가)

  • Lee, Yangwon;Jung, Eun-Suk;Choi, Kyoung Young;Kim, Myung Han;Kwon, So Yong;Cho, Nam Sun;Kim, Jin Sook;Park, Han Jeong;Han, Byoung Don;Yoon, Soo-Young
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Background: Leukocyte reduction filters are widely used to prevent transfusion reactions caused by leukocytes in blood components. Commercial filters are not sufficient for removal of leukocytes for prevention of transfusion associated graft-versus-host disease; therefore, irradiation of blood components was performed using expensive equipment. Techniques using an aptamer substituted for antibody have been developed and are available in clinical areas. The purpose of this study is to develop the aptamer filter system and to evaluate its efficiency and the possibility of its clinical application. Methods: Aptamers targeted to CD45 were selected by the Postech Aptamer Initiative. The aptamer filter in which aptamers attached to beads were bound to leukocytes and removed by magnetic field was developed. Filtration of 14 units of leukoreduction-red blood provided by Korean Red Cross Blood Services was performed using aptamer filters. Leukocyte removal rate and red cell recovery rate were evaluated and bacterial culture was performed. Results: After filtration using the aptamer filters, 45.6% of leukocytes were additionally removed and the red cell recovery rate was 92.8%. No growth in the bacterial culture was observed. Conclusion: In order to apply the cell depletion technique utilizing an aptamer to blood filter system, we developed and evaluated the aptamer filter system. Through improvement of the binding efficiency of the aptamer and the filtering process, and application of the various aptamers for other different cells, we suggest that this technique can be applied in the clinical area, such as a substitution for the irradiation process for TAGVHD prevention.

Compilation of Books on Military Arts and Science and Ideology of Military Science in the early Joseon Dynasty (조선(朝鮮) 초기(初期)의 병서(兵書) 편찬(編纂)과 병학(兵學) 사상(思想))

  • Yun, Muhak
    • (The)Study of the Eastern Classic
    • /
    • no.49
    • /
    • pp.325-355
    • /
    • 2012
  • This research aims to generalize the thoughts of military science of the intellectuals through the books on military arts and science, which were published in the early Joseon Dynasty. In the early Joseon dynasty, it was in a position to establish the foundation in the new monarch internally, and, at the same time, to overcome foreign powers on both northern and southern borders externally. Thus, the books on military arts and science should have to be published under a premise of such situations. Accordingly, the books on military arts and science of those days took account of political stability having reflected the activities not only as the founder of Joseon but also as the military officer in the late Goryeo along with the books' own purpose to found military arts and sciences. The books on military arts and science that published in the early Joseon Dynasty were written mostly based on Chinese military books and its annotations, except some descriptions of the history of war. However, the intellectuals at that time endeavored to redefine military arts and science from the perspective of Confucianism having evaluated Chinese military science books that were biased to boost Machiavellian tactics. As a result of this, the geographical distinctions between China and Korea were the start of an argument for the military arts and science. There were also disputes over the relationships between the military science and the Yin-Yang School, and between the military science and Confucian school. Organizing our country's own history of war for the first time in the early Joseon Dynasty is worth for putting a high evaluation. However, it cannot help but to point out the limits of the books that there are noticeable descriptions about the factors related to toadyism, and that there are no descriptions about the wars against Japanese raiders. The books on military arts and science in the early Joseon Dynasty put emphasis on the commander's leadership that should be good at both literary and martial arts, as well as the harmony in military-to-military relations. After all, the intellectuals in the early Joseon Dynasty had linked the military arts and science to the sages of Confucian school under a premise that scholarship is to be used in combination with martial arts. And, as the nexus between the two, they noted the items of virtue, such as humaneness and righteousness (仁義); ritual and music (禮樂); loyalty and filial piety (忠孝); three fundamental principles (三綱); five moral disciplines (五倫). It can be said that this point is the typical features of the military arts and science in the early Joseon Dynasty, which cannot be found in Chinese military classics.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.