• Title/Summary/Keyword: Evaluation parameter

Search Result 1,648, Processing Time 0.034 seconds

An epidemiological study of human paragonimiasis by means of micro-ELISA (면역효소진단법을 이용한 폐흡충증 유행의 역학조사)

  • 조승열;이동근강신영김석일
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.246-256
    • /
    • 1983
  • As epidemiological parameters of human paragonimiasis, the positive rates of intradermal test and the sputum/stool ekaminations have long been employed in population surveys. However, both the specificity of the intradermal test and the sensitivity of sputumjstool examination have been gradually declined as the endemicity was lowered; thus the gap between above two parameters widened. In such context, the development of a new epidemiologic parameter or tool which makes it possible to accurately discriminate the active paragonimiasis cases was necessary. In the present study, the detection rate of Paragonimus-speclac IgG antibody by micro-ELISA was evaluated as an indicator of epidemiologic status of human paragonimiasis in a population. A total of 4, 285 students and inhabitants living in Bukpyeong Myeon and Bukil Myeon, Haenam Gun, Jeonlanam Do was surveyed in October, 1983 by intradermal test first. Out of them, 244 cases (5.7%) were found positively reacted to VBS antigen of F. westermani. Out of 168 positive reactors, 7 cases (4.2%) were egg positive either by two times of sputum examination or by one stool examination. That indicated that only 0. 16% of total surveyed were confirmed as active paragonimiasis by egg detection. When sera collected from 239 positive reactors of Intradermal test were tested by micro-ELISA for their specific IgG antibody, 40 cases(16.7%) were found to be positive. All of 7 egg positive cases were again positive for specific IgG antibody. Among remaining 232 intradermal test positive cases, 33 cases were positive for IgG antibody. In contrast to those, none of 42 positive reactors to intradermal test for Cloncrchis and of 128 intradermal test negative cases showed positive for Paragcnimus-specIfic IgG antibody. The rate of specific IgG antibody as detected by micro-ELISA appeared to be increased with the wheal size of the intradermal test. When the wheal sixte was over 13mm in diameter, about 50% of them were positive for specific IgG antibody. Thirty-one specific antibody positive cases were clinically evaluated by laboratory examinations (repeated sputum examination, peripheral eosinophil count and chest roentgenogram) and by history taking. Out of them 24 cases were associated with one or more positive laboratory findings: thus considered as active paragonimiasis cases. Out of 7 lab. finding-free cases 3 revealed past history of typical paragonimiasis symptoms, suggesting that they were in chronic or in convalescent stages. The remaining 4 cases were considered as either mild or ectopic infection cases; the possibility of cross-reaction with other helminthiases could not be ruled out. From the above results, it was inferred that the detection of Paragonimus-specIfic IgG antibody by micro-ELISA was very much helpful in detecting the active cases as well as in proper evaluation of the endemicity of human paragonimiasis in a population. The convenience of mass haildling of sera in micro-ELISA was considered another superiority as an epidemiologic tool.

  • PDF

Estimation of Genetic Parameters for Milk Production Traits in Holstein Dairy Cattle (홀스타인의 유생산형질에 대한 유전모수 추정)

  • Cho, Chungil;Cho, Kwanghyeon;Choy, Yunho;Choi, Jaekwan;Choi, Taejeong;Park, Byoungho;Lee, Seungsu
    • Journal of Animal Science and Technology
    • /
    • v.55 no.1
    • /
    • pp.7-11
    • /
    • 2013
  • The purpose of this study was to estimate (co) variance components of three milk production traits for genetic evaluation using a multiple lactation model. Each of the first five lactations was treated as different traits. For the parameter estimation study, a data set was set up including lactations from cows calved from 2001 to 2009. The total number of raw lactation records in first to fifth parities reached 1,416,589. At least 10 cows were required for each contemporary group, herd-year-season effect. Sires with fewer than 10 daughters were discarded. Lactations with 305d milk yield exceeding 15,000 kg were removed. In total, 1,456 sires of cows were remained after all the selection steps. A complete pedigree consisting of 292,382 records was used for the study. A sire model containing herd-year-season, caving age, and sire additive genetic effects was applied to the selected lactation data and pedigree for estimating (co) variance components via VCE. Heritabilities and genetic or residual correlations were then derived from the (co) variance estimates using R package. Genetic correlations between lactations ranged from 0.76 to 0.98 for milk yield, 0.79~1.00 for fat yield, 0.75~1.00 for protein yield. On individual lactation basis, relatively low heritability values were obtained 0.14~0.23, 0.13~0.20 and 0.14~0.19 for milk, fat, and protein yields, respectively. For the combined lactation heritability values were 0.29, 0.28, and 0.26 for milk, fat, and protein yields. The estimated parameters will be used in national genetic evaluations for production traits.

Characteristics Evaluation of Combustion by Analysis of Fuel Gas Using Refuse-derived Fuel by Mixing Different Ratios with Organic and Combustible Wastes (배연가스 분석에 의한 가연성과 유기성폐기물을 혼합한 고형화연료 연소 특성평가)

  • Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.27-39
    • /
    • 2009
  • The main objective of this study is to investigate the characteristics of combustion by analyzing fuel gases from a combustion equipment with various combustion conditions for refuse-derived fuels (RDFs). CO gas is a parameter for indicating of incomplete combustion during a combustion process. The lowest CO gas was produced when the experiment conditions were m=2 under air-fuel condition and $800^{\circ}C$. $CO_2$ gas is a final product after complete combustions. The highest amount of $CO_2$ gas was produced when the experiment conditions were m=2 under air-fuel condition and $800^{\circ}C$. The highest level of $SO_2$ gas was produced in S.1 sample containing the highest sulfur. The highest level of NOx gas was produced in S.1 sample with the highest nitrogen content and air-fuel condition of m=2 under temperature of $800^{\circ}C$. HCl gas that is generated by reacting with metals catalyst through oxygen catalyst reaction during combustion process is a precursor of dioxin formation. The higher level of HCl gas was produced in the sample with higher chlorine content. The lowest level of HCl gas was produced when the experiment conditions were air-fuel condition of m=2 and $800^{\circ}C$. The lowest level of $NH_3$ gas was generated when the experiment condition was m=2 under air-fuel condition and after 3 minutes. Air-fuel condition is more important to create $NH_3$ gas than operating temperatures. Higher level of $H_2S$ gas was generated in S.1 sample with the higher sulfur content and was created in RDFs that contain higher mixture ratios of sewage sludge and food wastes. A result of combustion, gases and gases levels from the combustion of S.1 and S.2 were very similar to the combustion of a stone coal. As results of this research, when evaluating the feasibility of the RDFs, the RDFs could be used as auxiliary and main fuels.

  • PDF

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

Laparoscopy Assisted versus Open Distal Gastrectomy with D2 Lymph Node Dissection for Advanced Gastric Cancer: Design and Rationale of a Phase II Randomized Controlled Multicenter Trial (COACT 1001)

  • Nam, Byung Ho;Kim, Young-Woo;Reim, Daniel;Eom, Bang Wool;Yu, Wan Sik;Park, Young Kyu;Ryu, Keun Won;Lee, Young Joon;Yoon, Hong Man;Lee, Jun Ho;Jeong, Oh;Jeong, Sang Ho;Lee, Sang Eok;Lee, Sang Ho;Yoon, Ki Young;Seo, Kyung Won;Chung, Ho Young;Kwon, Oh Kyoung;Kim, Tae Bong;Lee, Woon Ki;Park, Seong Heum;Sul, Ji-Young;Yang, Dae Hyun;Lee, Jong Seok
    • Journal of Gastric Cancer
    • /
    • v.13 no.3
    • /
    • pp.164-171
    • /
    • 2013
  • Purpose: Laparoscopy-assisted distal gastrectomy for early gastric cancer has gained acceptance and popularity worldwide. However, laparoscopy-assisted distal gastrectomy for advanced gastric cancer is still controversial. Therefore, we propose this prospective randomized controlled multi-center trial in order to evaluate the safety and feasibility of laparoscopy assisted D2-gastrectomy for advanced stage gastric cancer. Materials and Methods: Patients undergoing distal gastrectomy for advanced gastric cancer staged cT2/3/4 cN0/1/2/3a cM0 by endoscopy and computed tomography are eligible for enrollment after giving their informed consent. Patients will be randomized either to laparoscopyassisted distal gastrectomy or open distal gastrectomy. Sample size calculation revealed that 102 patients are to be included per treatment arm. The primary endpoint is the non-compliance rate of D2 dissection; relevant secondary endpoints are three-year disease free survival, surgical and postoperative complications, hospital stay and unanimity rate of D2 dissection evaluated by reviewing the intraoperative video documentation. Discussion: Oncologic safety is the major concern regarding laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Therefore, the non-compliance rate of clearing the N2 area was chosen as the most important parameter for the technical feasibility of the laparoscopic procedure. Furthermore, surgical quality will be carefully reviewed, that is, three independent experts will review the video records and score with a check list. For a long-term result, disease free survival is considered a secondary endpoint for this trial. This study will offer promising evidence of the feasibility and safety of Laparoscopy-assisted distal gastrectomy for advanced gastric cancer. Trial Registration: NCT01088204 (international), NCCCTS-09-448 (Korea).

Bond Characteristics and Splitting Bond Stress on Steel Fiber Reinforced Reactive Powder Concrete (강섬유로 보강된 반응성 분체 콘크리트의 부착특성과 쪼갬인장강도)

  • Choi, Hyun-Ki;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.651-660
    • /
    • 2014
  • Structural members using ultra high strength concrete which usually used with steel fiber is designed with guidelines based on several investigation of SF-RPC(steel fiber reinforced reactive powder concrete). However, there are not clear design method yet. Especially, SF-RPC member should be casted with steam(90 degree delicious) and members with SF-RPC usually used with precast members. Although the most important design parameter is development method between SF-RPC and steel reinforcement(rebar), there are no clear design method in the SF-RPC member design guidelines. There are many controversial problems on safety and economy. Therefore, in order to make design more optimum safe design, in this study, we investigated bond stress between steel rebar and SF-RPC according to test. Test results were compared with previously suggested analysis method. Test was carried out with direct pull out test using variables of compressive strength of concrete, concrete cover and inclusion ratio of steel fiber. According to test results, bond stress between steel rebar and SF-RPC increased with increase of compressive strength of concrete and concrete cover. Increasing rate of bond stress were decrease with increase of compressive strength of SF-RPC and concrete cover significantly. 1% volume fraction inclusion of steel fiber increase the bond stress between steel rebar and SF-RPC with two times but 2% volume fraction cannot affect the bond stress significantly. There are no exact or empirical equations for evaluation of SF-RPC bond stress. In order to make safe bond design of SF-RPC precast members, previously suggested analysis method for bond stress by Tepfers were evaluated. This method have shown good agreement with test results, especially for steel fiber reinforced RPC.

Pleural Fluid to Serum Cholinesterase Ratio for the Differential Diagnosis of Transudates and Exsudates (여출액과 삼출액의 감별진단을 위한 흉막액과 혈청에서의 Cholinesterase 비율의 진단적 의의)

  • Cho, Ho;Kim, Hyun-Il;Eum, Min-Sup;Kwon, Han-Jin;Oh, Yong-Leul;Kim, Kwang-Suk;Kim, Hui-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.781-787
    • /
    • 2000
  • Background : The established by Light et al in 1972 have been used widely for the differential diagnosis of the pleural effusions in transudates and exsudates. However, in recent years, several reports have agreed that these criteria misclassified an important number of effusions. For this reason, different parameters have been proposed for differentiating the transudates from exudates. Nevertheless, all these alternative parameters have not been better than the past criteria of Light et al. In response the usefulness of two parameters for differentiating pleural transudate from exudates were evaluated : pleural fluid cholinesterase level and pleural fluid to serum cholinesterase ratio. Methods : A total of forty-three patients with known causes of the pleural of the pleural effusion by diagnostic thoracentesis were studied. The following criteria for differentiating the pleural effusions in transudates and exsudates were analyzed : Ligt's criteria, the pleural fluid cholesterol level, the pleural fluid to serum cholesterol ratio, the pleural fluid cholinesterase level, and the pleural fluid to serum cholinesterase ratio. Results : The conditions of forty-three patients were diagnosed. Ten were classified as having transudates and thirty-three as exudates. The percentage of effusions misclassified by each parameter was as follows : Light's criteria, 9.3% ; pleural fluid cholesterol 2.3% ; pleural fluid to serum cholesterol, ratio, 2.3% ; pleural fluid cholinesterase, 4.7% ; and pleural fluid to serum chlinesterase ratio, 2.3%. Conclusions : The pleural fluid to serum cholinesterase ratio is one of the accurate criteria for differentiating pleural transudates from exudates. If fur1her studies confirm the results, the cholinesterase ratio could be used as the first step in the evaluation of pleural effusion and, if evaluated together with the other criteria, the differentiation of pleural transudate from exsudates will become more accurate.

  • PDF

Preparation of Semi-Solid Apple-Based Baby Food (반고형 사과 이유보충식의 제조)

  • Sohn, Kyung-Hee;Kim, Mi-Ran;Yim, Sung-Kyoung;Park, Hyun-Kyung;Park, Ok-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2002
  • To develop commercial semi-solid apple baby food, the physicochemical characteristics of apple puree in relation to different preparing methods and the effect of the addition methods of ascorbic acid on browning reaction were investigated. The preparing methods were classified into 3 groups by initial heating treatment: no heating (A), steaming at $120^{\circ}C$ (B), and blancing at $100^{\circ}C$ (C). The viscosity of tested apple puree was $2,600{\sim}5,856\;cp$, and contents of anhydrogalaturonic acid (AGA) and neutral sugar ranged $4.15{\sim}11.92\;mg%$ and $6.18{\sim}10.65\;mg%$, respectively. Among free sugars tested, level of fructose was the highest $(5.43{\sim}8.87%)$, followed by glucose $(2.11{\sim}4.23%)$, sucrose $(1.64{\sim}2.94%)$, in that order. Since small amounts of ascorbic acid were detected $(1.54{\sim}1.83\;mg%)$, it seemed to be lost by heating process in preparing of apple puree. For apple puree A, its lightness was lower and redness was higher than those of apple puree B and C. Its degree of browning of apple puree was so high that sodium ascorbic acid was added as a antibrowning agent. Puree had low sensory score and nutrient quality. The adding methods of ascorbic acid were classified into 4 groups by adding time: dipping, blending (2), heating (3), and blending + heating (4). Considering color and preference evaluation, preparing method B and adding method 2 showed the highest inhibitory activity on apple puree browning and desirable color for retort baby food. After retort sterilization, the viscosity of apple baby food was decreased from 3,477 cp to 2,294 cp, thiamin was destroyed completely, and the contents of riboflavin and ascorbic acid were decreased 41% and 21%, respectively. However, contents of free sugar and free amino acid and sensory parameter were not influenced by retort sterilization. In overall, the preparing method B-adding method 2 was a good processing condition for the retort apple baby food.

Physicochemical Changes in Olive Flounder (Paralichthys olivaceus) Muscle by Iced Water Pre-treatment (얼음물 전처리 방법이 넙치육의 품질특성에 미치는 영향)

  • Shin, Seung-Ho;Sung, Ki-Hyub;Chung, Chang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.700-707
    • /
    • 2013
  • The purpose of this study was to monitor physicochemical changes of olive flounder (Paralichthys olivaceus) muscle by iced water pre-treatment. Moisture content, crude fat content, nucleotide content, texture (hardness and toughness), and rigor mortis were assessed. The sensory evaluation was performed with a nine-point hedonic test. K-values, a parameter of fish flesh freshness, were also calculated from the content of nucleotides and their corresponding decomposition products. Pre-treatment of flounder flesh with iced water was found to be fresher compared to the control, as determined by a difference in the K-values. Iced water pre-treatment hastened postmortem stiffness, as judged from the rigor index, and increased inosine monophosphate (IMP), which is known to be a savory taste compound, more quickly as adenosine triphosphate (ATP) degradation proceeded.

Usability Research of Onco Flash in SPECT (SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가)

  • Noh, Ik-Sang;Cha, Eun-Sun;Kim, Ki;Choi, Choon-Ki;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.3-8
    • /
    • 2009
  • Purpose: Onco flash shortens a scan time with half and there is a possibility of getting the data which corresponds in existing. The experiment which makes the image whose Onco Flash is excellent OSEM tried, as changes parameter of time, iteration. After reconstituting an image, produces FWHM and executes an evaluation. Materials and Methods: Siemens e.cam gamma camera, standard Jaszczak phantom and spatial resolution phantom was used. In order for the bubble not to enter, implants 2 mCi and volume 0.25 cc $^{99m}Tc$ respectively in line 3 to spatial resolution phantom. Put on that phantom on the table correctly, and acquires an image. 15 mCi putting in distilled water to mix $^{99m}Tc$ well in Jaszczak phantom and acquires image just like spatial resolution phantom. Reconstructs and converts the image to digital image as Sante program. Produce FWHM and evaluate by Amide. Results: The non-scattered image shows better FWHM value than scattered image. As time increases from 10 sec to 30 sec for 5sec interval, FWHM appeared to 30.1, 28.5, 24.5, 23.6, 23.4 mm. At the standard iteration value 4, OSEM FWHM shows 8.0 mm, and Onco Flash is 8.1 mm. As fade in iteration, FWHM value more and more decreased. Conclusion: When using Onco Flash, shortens a scan time, and enhances image quality. Also, user can adjust the parameters to improve resolution. Therefore, patient and user are satisfied with these merits.

  • PDF