• Title/Summary/Keyword: Evaluation of Daylight

Search Result 77, Processing Time 0.021 seconds

Visual Comfort Evaluation of Interior Spaces by Daylighting Systems (채광시스템 유형별 실내공간의 시각적 쾌적성에 관한 평가)

  • Jeong, In Young;Choi, Yoon Seck;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Daylight is a critical factor in architecture, as it enhances the working efficiency and visual comfort of the people working inside. Even though, low transmittance glazing has been used in the most office buildings in Korea. And it is reduced visual comfort in a indoor environment. So, we need to evaluation of quality for various daylighting systems to improve visual comfort This study aims to evaluate the visual comfort in a indoor environment by different daylighting system. For the purpose, four different daylighting systems-conventional window, conventional window with interior lightshelf, differentiated window, differentiated window with interior lightshelf-were selected and a questionnaire survey with 50 subjects were conducted. The results are as follows. Regardless daylighting systems, a view has an effect on visual comfort. A conventional system and conventional system with lightshelf were highly correlated between comfort and warmth. In case of differentiated window system were correlated between comfort and openness. Also, differentiated window with interior lightshelf were highly correlated between comfort and stability.

A Study on the Images and Preference of Lighting Space - Focusing on fashion Stores - (조명공간의 이미지 및 선호도 연구 - 패션 매장을 중심으로 -)

  • Seok, Hye-Jung;Han, Seung-Hee;Lee, Jong-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.3
    • /
    • pp.1-11
    • /
    • 2015
  • This study comparatively analyzed the images and preference of lighting space using the emotion-based technique in order to effectively use it in clothing shops and fashion marketing. In terms of color temperature for light sources, 2,800K of lamp color, 6,500K of daylight color and 4,200K of white color were used. For the assessment, sensory evaluation technique was used. Then, the study found the followings: In terms of the image of lighting space by light source, different images were observed by light source with significant difference by the evaluation category. For factor analysis by the evaluation category, 7 factors were extracted. Among them, evaluation on lighting space was influenced by the following three images: modern space, elegant space and classical space. In particular, the modern space comprised of the following adjectives had the biggest effect on the assessment of the image of lighting space ('refreshing,' 'transparent,' 'bluish,' 'bright' and 'non-classical') (primary evaluation 30.13%). According to assessment on the preference of lighting space, the respondents' most favorite lighting space was 4,200K while their least favorable one was 6,500K in terms of color temperature. In terms of preference by the image of lighting space, they didn't like 'non-elegant' and 'non-beige' images even though they had the images of modern space. Therefore, it was confirmed that beige and elegant space images have an effect on the preference of lighting space.

  • PDF

A Study on Antioxidant and Antibacterial Efficacy Evaluation and Cosmetic Application of Rumex crispus L. Root Extract (소루쟁이 뿌리 추출물(Rumex crispus L.)의 라디칼 소거능과 항균력 평가 및 화장품 적용 가능성에 관한 연구)

  • Yu-Jin Park;Jae-Chan Yang
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.159-171
    • /
    • 2024
  • This study confirmed the antioxidant activity and antimicrobial efficacy and formulation stability for the effectiveness experiment of Rumex crispus. L root extract. For antioxidant activity, DPPH radical scavenging, FRAP activity, ABTS+ radical scavenging, and SOD-like activity were performed. Antimicrobial activity was evaluated for Staphylococcus epidermidis, Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli and Candida albicans strains. In addition, skin containing Rumex crispus. L root extract is checked over time for pH, temperature, and daylight for 21 days. As a result of antioxidant evaluation, it was confirmed that the activity increased in a concentration-dependent manner at a concentration of 0.0625-1 mg/mL. The clear zones of each bacterium at 100mg/mL concentrations were 10.45±0.34, 9.77±0.59, 9.92±0.22, and 10.08±0.12, which were superior to the control group Methyl paraben, and the antibacterial power of S. aureus and E. coli was confirmed at 100mg/mL concentration for MIC. There was little change in absorbance when the pH of the skin was 4.0, 6.0, and 7.0 and At 4℃, 25℃, and 40℃, it was discolored as the temperature increased. It was also observed that discoloration occurred when exposed to daylight. This is presumed to be able to prevent discoloration when it is shielded and stored at low temperatures. When the results of this study are summarized, Rumex crispus. L root extract is considered to have high value in use as a cosmetic raw material that can expect antioxidant and antibacterial activities.

Development of Nomographs for the Evaluation of Lighting Energy Performance in a Semi-infinite Office Space (중규모 사무공간에서 조명에너지 성능평가를 위한 노모그래프 개발에 관한 연구)

  • Kim, Han-Seong;Ko, Dong-Hwan;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.73-80
    • /
    • 2003
  • The purpose of this study was to analyze daylighting performance in a semi-infinite size office space for lighting energy conservation. DOE2.1E was used for simulations for the model space of $12\times12\times2.6m$. Nomographs were developed which could simulate work plane illuminance, glare index, energy consumption rate and energy reduction rate for daylighting design. Major results of simulations are as follows ; 1) When blinds facing south were installed, 43% of workplane illuminance diminished, but the flare index didn't exceed the recommended max-glare value. 2) In a semi-infinite office space facing south. energy consumption rate in the case space of 500 lux workplane illuminance is larger then case space of 300 lux workplane illuminance. Therefore, energy reduction rate is increased when the semi-infinite office faces south and naintains 300 lux workplane illuminance level.

A Systematic Categorization of Interior Environmental Design Elements for Improving Sustainability - With Particular Reference to Unit Plan Design Elements of High-rise Apartment - (지속가능한 실내환경디자인 요소의 체계적 분류 - 초고층 아파트 단위 주공간의 디자인요소를 중심으로 -)

  • Lee Eun-Jung;Park Young-Ki
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.48-55
    • /
    • 2006
  • A sustainable building must produce an interior environment that is safe, healthy, comfortable and supportive of human performance and well-being. The medical human comfort: performance and productivity cost of unhealthy environment may cause much cost for healing. Research that buildings with daylight, fresh air, eco-materials and sustainable interior design are consistently rated as more comfortable and occupants performance, satisfaction and health. This study is to categorize systematically interior environmental design elements for improving sustainability with a view to developing an evaluation model of super high-rise apartment unit plans. With a literature survey and design guide lines concerning sustainable design elements, three hierarchical categorization levels of human, environment, energy and resources systems that consists of upper, middle, low design elements have been proposed. A total of 6 items have been suggested for middle level of categorization and 24 items for lower level. Finally a total of 107 design elements concerning the 24 items and their relationahips have been revealed. The needs for a systematic approach to interior environmental design for sustainability have been discussed.

Analyzing Shading Characteristics of Venetian Blinds Using the RADIANCE Program (RADIANCE 프로그램을 이용한 베네치안 블라인드의 차양특성 분석)

  • Song, Kyoo-Dong;Kim, Min-Sung;Kim, Ji-Hyun
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.3-9
    • /
    • 2005
  • Venetian blinds are used with windows to improve the uniformity ratio of illuminance and interior daylighting distribution under direct sunlit conditions. The main objective of Venetian blinds shading system is to obstruct direct sunlight and at the same time allow daylight to penetrate into the room. Venetian blinds would have greater effect on the interior daylighting condition under clear sky which has both skylight and sunlight than overcast sky which has only skylight. However, due to the lack of data, design and evaluation tools, it is difficult for architects to choose or install venetian blinds during the building design stages. The purpose of this study was to develop an analysis method for shading and daylighting effects of Venetian blinds using the RADIANCE program. The major variables related to the venetian blinds included blinds's slat angle and the ratio of slat width to window height, the radius slat of curvature and the building azimuth. In this study, a series of parametric physical mock-up model measurements and genblinds command in the RADIANCE simulations. The results of this study will provide building designers with the design data at early design stages.

Automated Blind Control Strategy to Minimize Occupant's Distractions (재실자 방해 최소화를 위한 자동 블라인드 제어 방안)

  • Koo, So-Young;Yeo, Myoung-Souk;Seong, Yoon-Bok;Kim, Kwang-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.84-92
    • /
    • 2013
  • Blinds are a common type of shading device and are increasingly operated automatically to overcome the limitations of manual operation. Automated blinds need to be controlled to maximize benefits of daylight in the point of occupant comfort and energy consumption. However, the previous control methods could cause occupant's distractions by the undesirable control time interval and amount of blind movement. A few researches suggested the control concept for minimizing occupant's distractions by automatic blind control, but they did not provide optimal control algorithm to be useful in practice. In this paper, we propose an optimal control algorithm for automated blinds that can maximize not only visual comfort but also sunlight penetration into buildings based on occupants' preferences on blind movement and sunlight. The proposed control algorithm can prevent solar glare on workplane and minimize occupant's distractions to maximize occupants' visual comfort.

Vehicle HUD's cognitive emotional evaluation - Focused on color visibility of driving information (차량용 HUD의 인지적 감성 평가 -주행정보의 색채 시인성을 중심으로-)

  • Choi, Won-Jung;Lee, Won-Jung;Lee, Seol-Hee;Park, YungKyung
    • Science of Emotion and Sensibility
    • /
    • v.16 no.2
    • /
    • pp.195-206
    • /
    • 2013
  • The main causes of traffic accidents while driving a car is of the driver's visual distraction. In this study, the color sensitivity of the information projected on the windshield were evaluated for HUD (Head Up Display) system which helps the driver's eyes on the road while driving. The driving Information were projected $9^{\circ}$ downward from front sight $0^{\circ}$ under lab's fluorescent lights, LED floorlights and the TV had having 25 [lux] illumination when driving at night environment and 100,000 [lux] of daylight environment. Munsell color hue of the basic five colors (R, Y, G, B, P) and the color of traffic lights YR, W were the color of the seven characters, each character were outlined by White, Gray except for W. Total of 19 experimental stimuli was shown in the environment of day and night driving for asking visibility information of color, fatigue, preferences, and evaluate the degree of interference. The results came out that the bright Y and G color is visibility significantly for daylight. Second, with the outline of the text, the color of the outline works as a background for luminance contrast effects and affects visibility. Third, without the outline, the glass in front of the vehicle acts as the background and the luminance contrast of characters achieve greater brightness and visibility. The luminance contrast between the stimuli and background should be considered for increasing color visibility for driving information which is an important factor for HUD commercialization.

  • PDF

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

Perceived color shift of ceramics according to the change of illuminating light with spectroradiometer

  • Cha, Hyun-Suk;Yu, Bin;Lee, Yong-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.262-269
    • /
    • 2013
  • PURPOSE. Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically simulated seven all-ceramics due to the switch of three ambient light sources using a human vision simulating spectroradiometer. MATERIALS AND METHODS. CIE color coordinates, such as $L^*$, $a^*$ and $b^*$, of ceramic specimens were measured under three light sources, which simulate the CIE standard illuminant D65 (daylight), A (incandescent lamp), and F9 (fluorescent lamp). Shifts in color and color coordinate by the switch of lights were determined. Influence of the switched light (D65 to A, or D65 to F9), shade of veneer ceramics (A2 or A3), and brand of ceramics on the shifts was analyzed by a three-way ANOVA. RESULTS. Shifts in color and color coordinates were influenced by three factors (P<.05). Color shifts by the switch to A were in the range of 5.9 to 7.7 ${\Delta}E{^*}_{ab}$ units, and those by the switch to F9 were 7.7 to 10.2; all of which were unacceptable (${\Delta}E{^*}_{ab}$ > 5.5). When switched to A, CIE $a^*$ increased (${\Delta}a^*$: 5.6 to 7.6), however, CIE $b^*$ increased (${\Delta}b^*$: 4.9 to 7.8) when switched to F9. CONCLUSION. Clinically simulated ceramics demonstrated clinically unacceptable color shifts according to the switches in ambient lights based on spectroradiometric readings. Therefore, shade matching and compatibility evaluation should be performed considering ambient lighting conditions and should be done under most relevant lighting condition.