• Title/Summary/Keyword: Evaluation indoor air environment

Search Result 164, Processing Time 0.026 seconds

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner with Ventilation System for Heating Season (환기시스템이 적용된 히트펌프의 난방시 급기효율 평가에 관한 연구)

  • Kwon Yong-Il;Han Hwataik;Kim Kyung-Hwan;Chung Baik-Young;Lee Gam-Gue
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.56-61
    • /
    • 2005
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors (보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가)

  • Lee, Boram;Lee, Daeyeop;Ban, Hyunkyung;Lee, Sewon;Kim, KyooSang;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

A Comparative Study of a Domestic and Foreign Green Architecture Evaluation Items for a Green Performance Enhancement of Hospital Architecture (병원건축의 친환경 성능 향상을 위한 국내외 친환경 건축물 평가항목의 비교 연구)

  • Lee, Ho-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.99-107
    • /
    • 2009
  • In order to prepare future green hospital architecture authentication system, this study is a comparative year report to Korean, the United States, Japanese, British, Canadian and Australian green building authentication systems. Also, the United States and Australian Green hospital authentication systems were examined, and the authentication items of hospitals were compared with those of civil architecture. Though the examination and analysis, the portion of indoor environmental quality section commonly shows the average of 20.7 percent in all 6 countries. Especially, IAQ(Indoor Air Quality) among inside IEQ(Indoor Environment Quality) is overwhelmingly much treated in Korea, the U.S.A, Canada and Australia. In Japan, heat, light and sound are the important factors for authentication evaluation, while in the U.K light are more emphasized for the authentication. 'LEED for Healthcare' as a hospital evaluation authentication system subdivided currently most. The system includes the detailed and extensive evaluation items ranging from hospital management, traffic, emission, water resources utilization to integrated design and furnishing. These overseas systems should be carefully investigated, researched and analyzed for an appropriate improvement of domestic green hospital authentication system. Also the current evaluation method of IEQ section of Korean GBCC needs to be modified. That's why the method puts too much importance on IAQ in IEQ section.

Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator - (직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 -)

  • Seo, Jang-Won;Kim, Young-Il;Lee, Hee-Sun;Kim, Ji-Hun;Kim, Young-Doo;Shin, Jin-Ho
    • Particle and aerosol research
    • /
    • v.17 no.4
    • /
    • pp.115-123
    • /
    • 2021
  • The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

Evaluation of Thermal Environment on Air-barrier Type Perimeter-less System with Underfloor Air Conditioning System (바닥급기 공조시 에어베리어형 페리미터레스 공조시스템의 실내 열환경 평가)

  • 김용경;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.346-351
    • /
    • 2003
  • This paper aims at suggesting design guidelines for a perimeter-less HVAC system that contributes energy savings. Perimeter-less HVAC system is one that relieves difficulties fuck as handling mixing loss, uneven radiative environment, and maintenance and repair. It prevents heat load gained through window and outdoor wall without modifying a previously equipped building skin system. In this paper, we performed several kinds of CFD (computational fluid dynamics) cases through numerical simulation to obtain an optimized perimeter-less design, and then we conducted a large-scale model experiment to see how the push-pull air flow would handle indoor heat to obtain an optimized perimeter-less design.

Uncertainty Evaluation in Measurement of Deodorization Efficiency of Indoor Air Cleaner (탈취제품의 탈취 성능 측정의 불확도 평가)

  • 허귀석;신상만;김정우;이진홍
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.384-385
    • /
    • 2003
  • 일상 생활에서 악취로 인한 피해를 줄여 쾌적한 생활환경 유지에 대한 관심이 높아짐에 따라 이에 관련된 탈취제품이 많이 상품화되고 있다. 본 연구에서는 탈취 성능에 대하여 객관적으로 평가할 수 있는 시험 분석법을 개발하고, 탈취 성능 평가방법의 정확도를 확립하기 위해 단계별 불확도 평가를 수행하였다. 측정 불확도 요인을 체계적으로 평가하여 주요 불확도 요인을 파악하고 이를 최소화하기 위하여 어떠한 점을 주의하여야 하는 지를 조사하였다. (중략)

  • PDF

Comparative Evaluation of Measurement Methods for Suspended Particles in Indoor and Outdoor Air (실내ㆍ외 공기중 부유먼지 측정방법 상호간의 비교평가)

  • 백성옥;박지혜;최진수;박상곤
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.37-38
    • /
    • 2002
  • 부유먼지가 인체에 미치는 유해성을 평가하기 위해서는 무엇보다도 공인되어 있고 신뢰성 있는 측정방법이 마련되어 있어야 한다. 대기중 부유먼지의 측정방법에는 여러 가지가 있으나 측정원리의 측면에서는 중량법과 광학적방법으로, 포집유량의 측면에서는 high-volume 과 low-volume으로 구분되어지며 임자의 크기별 포집장치의 부착유무에 따라 입도 분리형과 비분리형으로 구분되어지기도 한다. (중략)

  • PDF

A study of the paint characteristic evaluation for building complete materials (건축용 마감재 페인트의 성능평가에 관한 연구)

  • Park, Min-Su;Kim, Sun-Tae;Son, Chan-Woong;Kim, Han-Tae;Lee, Baek-Hyun
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.177-178
    • /
    • 2002
  • 최근 삶의 질이 향상은 건강에 대한 환경적 관심으로 연계되고 있다. 특히 현대인의 생활양식과 근무양식이 1일 실내 생활시간이 전체의 80%이상으로 변화함에 따라 실내공기질(Indoor Air Quality : 이하 IAQ)이 인간에게 직접적인 미치는 영향에 대해 높은 관심을 나타내고 있다. 실내공기는 일정수준의 외기 도입이 없는 경우, 한정된 공간을 오염된 공기가 계속 순환하면서 오염물질이 누적될 수 있다. (중략)

  • PDF

A Study on the Environment-friendly Assessment Elements for Apartment Unit Plan (공동주택 단위주호의 환경친화성 평가요소에 관한 연구)

  • Cho, Sung-Heui;Park, Ji-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.11-20
    • /
    • 2002
  • The purpose of this study is to suggest environment-friendly assessment elements for the apartment unit plan. For this, the organizing environments of a unit are classified through literature review. Those were five categories of environment: environment of solar system, light, water, green and indoor air Quality. Then, the assessment elements for each categorized environment to evaluate the environment-friendly performance were grasped definitely by examining the applicability of architectural methods or equipment technology. It is expected to suggest not only an assessment tool for evaluation but also a checklist for design in order to develope environment-friendly apartment unit plans.

Comparative Evaluation of Gravimetric Measurement Methods for Suspended Particles in Indoor and Outdoor Air (실내.외 공기 중 부유먼지 측정방법 상호간의 비교평가 - 중량법을 대상으로)

  • 백성옥;박지혜;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.4
    • /
    • pp.285-295
    • /
    • 2002
  • In this study, several types of gravimetric methods (such as high, medium, low, and ultra low volume sampling methods) were applied to determine suspended particulate matter concentrations in both ambient and indoor environments. Comparative evaluations were undertaken with SPM data obtained using a variety of samplers (TSP, PM10, and PM4.0) at different sampling flow rates. Correlation coefficients between TSP and PM10 concentrations measured at different flow rates fell in the range of 0.73∼0.94 (n=40). In addition, correlation coefficients for PM concentrations measured by different TSP samplers were in the range of 0.90∼0.95 (n=36 or n=38), while 0.77∼0.91 (n=38) for PM10 samplers. Correlation analysis was also conducted on indoor monitoring data that were measured using ultra-low-volume samplers at both different or identical flow rates. The correlation coefficients were in the range of 0.98∼0.99 (n=38) between TSP and TSP and 0.92∼0.94 (n=38) between TSP and PM10. The mean ratio for high volume PM10 to TSP concentration that was monitored at identical flow rates in the ambient air appeared to be 0.72. The mean ratios of PM10 to TSP and PM4.0 to TSP observed with identical flow rates at indoor environments were 0.47 and 0.40. The results of this study may provide empirical information concerning the compatability of aerosol data obtained by gravimetric sampling methods at different flow rates.