• 제목/요약/키워드: Evaluation error

검색결과 2,502건 처리시간 0.038초

Accuracy Evaluation and Enhancement of Machine Tools Using a Kinematic Ball Bar (기구볼바를 이용한 가공기계의 정밀도 평가 및 향상 기술 개발)

  • Moon, J.H.;Pahk, H.J.;Chu, C.N.
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제13권6호
    • /
    • pp.114-121
    • /
    • 1996
  • This paper presents an useful technique for assessing the volumetric errors in multi-axis machine tools using the kinematic double ball bar. This system has been developed based on the volumetric error map which describes the 3 dimensional errors of machine tools. The developed system inputs the measured radial data of 3 different planes, respectively XY,YZ,ZX, analysing the volumetric errors such as positional. straightness, angle, and squareness errors, etc. The developed system has been tested in a practical machine tool, and showed high potential for the error assessment of multi-axis machine tools.

  • PDF

The Influence of Eccentric Error in Horizontal Angle Measurement (수평각관측에 있어서 구심오차가 관측치에 미치는 영향)

  • 이계학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제9권1호
    • /
    • pp.55-61
    • /
    • 1991
  • The accidential errors of horizontal angles are influenced by sighting, reading and eccentric errors etc. This paper deals with the influence of eccentric error by the formula of theory and evaluation, and actually testing measurement. The results show that the eccentric error is calculated through the sighting distance, observed angle, eccentric distance and angle. And then, three repeating method is of practical use, and also, eccentric error is able to evaluate through the sighting distance and observed angle in according to performance of each instrument.

  • PDF

Partial Relay Selection for Decode and Forward over Rayleigh Fading Channels (레일리페이딩 환경에서 복호 후 재전송방식을 위한 부분적 릴레이 선택방식 연구)

  • Bao, Vo Nguyen Quoc;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제34권7A호
    • /
    • pp.523-529
    • /
    • 2009
  • This paper provides closed form expressions for the evaluation of the end-to-end outage probability, symbol error rate, bit error rate and average capacity of the partial-based Decode-and-Forward (DF) relay selection scheme with an arbitrary number of relays. In a comparison with the performance of systems that exploit Amplify-and-Forward (AF), it can be seen that the performance of our proposed protocol converges to that of partial-based AF relay selection in high SNR regime. We also perform Monte-Carlo simulations to validate the analysis.

An Evaluation of Error Performance Estimation Schemes for DS1 Transmission Systems Carrying Live Traffic

  • Eu, J.H.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • 제14권1호
    • /
    • pp.1-15
    • /
    • 1988
  • DS1 transmission systems use framing bit errors, bipolar violations and code-detected errors to estimate the bit error rate when determining errored and severely errored seconds. Using the coefficient of variation under the memoryless binary symmetric channel assumption, a basic framework to evaluate these estimation schemes is proposed to provide a practical guideline in determining errored and severely errored seconds which are fundamental in monitoring the real-ime error performance of DS1 transmission systems carrying live traffic. To evaluate the performance of the cyclic redundancy check code (CRC), a computer simulation model is used. Several drawbacks of the superframe format in association with real time error performance monitoring are discussed. A few recommendations are suggested in measuring errored and severely errored seconds, and determining service limit alarms through the use of the superframe format. Furthermore, we propose a new robust scheme for determining service limit alarms which take into consideration the limitations of some estimation schemes for the time interval of one second.

  • PDF

Comprehensive evaluation method for user interface design in nuclear power plant based on mental workload

  • Chen, Yu;Yan, Shengyuan;Tran, Cong Chi
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.453-462
    • /
    • 2019
  • Mental workload (MWL) is a major consideration for the user interface design in nuclear power plants (NPPs). However, each MWL evaluation method has its advantages and limitations, thus the evaluation and control methods based on multi-index methods are needed. In this study, fuzzy comprehensive evaluation (FCE) theory was adopted for assessment of interface designs in NPP based on operators' MWL. An evaluation index system and membership functions were established, and the weights were given using the combination of the variation coefficient and the entropy method. The results showed that multi-index methods such as performance measures (speed of task and error rate), subjective rating (NASA-TLX) and physiological measure (eye response) can be successfully integrated in FCE for user interface design assessment. The FCE method has a correlation coefficient compared with most of the original evaluation indices. Thus, this method might be applied for developing the tool to quickly and accurately assess the different display interfaces when considering the aspect of the operators' MWL.

Analysis of Packet Transmission Performance for Construction of Wireless Sensor Networks in Indoor Environment (실내환경에서 무선 센서 네트워크구축을 위한 패킷 전송성능평가)

  • Lee, Joa-Hyoung;Jung, In-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제13권9호
    • /
    • pp.1941-1946
    • /
    • 2009
  • Wireless sensor networks do the monitoring and collecting information in the environment instead of human. Sensor networks are consisted of small sensor nodes with very limited hardware resource and very low network bandwidth. The wireless communication environment causes lots of communication errors so that the sensor network requires error correction technique to increase the reliability of network. The performance of error correction technique could be increased by the researches about the error pattern of CRC. In the paper, we did the performance evaluation - transmission interval, distance between sensor nodes, racket size, and RF power - that affects to the success ratio of data transmission in the indoor environment. we propose the performance metrics of system configuration based on the analysis of performance evaluation.

Evaluation of the Numerical Models' Typhoon Track Predictability Based on the Moving Speed and Direction (이동속도와 방향을 고려한 수치모델의 태풍진로 예측성 평가)

  • Shin, Hyeonjin;Lee, WooJeong;Kang, KiRyong;Byun, Kun-Young;Yun, Won-Tae
    • Atmosphere
    • /
    • 제24권4호
    • /
    • pp.503-514
    • /
    • 2014
  • Evaluation of predictability of numerical models for tropical cyclone track was performed using along-and cross-track component. The along-and cross-track bias were useful indicators that show the numerical models predictability associated with cause of errors. Since forecast errors, standard deviation and consistency index of along-track component were greater than those of cross-track component, there was some rooms for improvement in alongtrack component. There was an overall slow bias. The most accurate model was JGSM for 24-hour forecast and ECMWF for 48~96-hour forecast in direct position error, along-track error and cross-track error. ECMWF and GFS had a high variability for 24-hour forecast. The results of predictability by track type showed that most significant errors of tropical cyclone track forecast were caused by the failure to estimate the recurvature phenomenon.

A Study on the Reliability Verification of Availability Simulation for Complex Plant (플랜트 가용도 평가 시뮬레이터의 신뢰성 검증에 관한 연구)

  • Lee, Hongcheol;Hwang, Inju;Lee, Hyundong
    • Korean Journal of Computational Design and Engineering
    • /
    • 제20권1호
    • /
    • pp.36-43
    • /
    • 2015
  • Recently, a number of evaluation studies on availability of plant were carried out. This study was conducted to verify of the reliability of a simulation with some variable such as configuration of process, failure probability density function and the number of iteration times for the natural gas liquefaction plant. The error rate of the KICT-RAM solution was evaluated as 0.03~1.79% compared with the result of the MAROS(commercial solution). And the error-rate change was observed in the range of 0.03~1.75 on the condition of the iteration times as 30, 100, 250. As a result the plant availability evaluation approach of KICT-RAM solution was verified as reasonable. However, the careful approach was required to use the solution because the error-rate increased according to iteration times change.

Adaptive Extraction Method for Phase Foreground Region in Laser Interferometry of Gear

  • Xian Wang;Yichao Zhao;Chaoyang Ju;Chaoyong Zhang
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.387-397
    • /
    • 2023
  • Tooth surface shape error is an important parameter in gear accuracy evaluation. When tooth surface shape error is measured by laser interferometry, the gear interferogram is highly distorted and the gray level distribution is not uniform. Therefore, it is important for gear interferometry to extract the foreground region from the gear interference fringe image directly and accurately. This paper presents an approach for foreground extraction in gear interference images by leveraging the sinusoidal variation characteristics shown by the interference fringes. A gray level mask with an adaptive threshold is established to capture the relevant features, while a local variance evaluation function is employed to analyze the fluctuation state of the interference image and derive a repair mask. By combining these masks, the foreground region is directly extracted. Comparative evaluations using qualitative and quantitative assessment methods are performed to compare the proposed algorithm with both reference results and traditional approaches. The experimental findings reveal a remarkable degree of matching between the algorithm and the reference results. As a result, this method shows great potential for widespread application in the foreground extraction of gear interference images.

Improvement of Precision in Ferroelectric Polarization Hysteresis Measurement (강유전체 분극 이력곡선의 측정 정밀도 향상)

  • Jae Hwan Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제30권3호
    • /
    • pp.51-55
    • /
    • 2023
  • Measurement of the ferroelectric polarization hysteresis curve is an important means of overall evaluation and interpretation of the ferroelectric structure and dielectric properties. If a resistive component is included in the ferroelectric sample, an error is included in the measured value of the spontaneous polarization. When configuring the electrical circuit to measure the polarization, by properly utilizing the external resistance corresponding to the resistive component included in the sample, the error due to the resistive loss of the sample was excluded and the size of the ferroelectric polarization induced inside could be accurately measured. It is expected that the displacement and dielectric characteristics of ions inside the ferroelectric can be more accurately evaluated through the evaluation of such an accurate polarization hysteresis curve.