• Title/Summary/Keyword: Evaluation and Validation Test

Search Result 264, Processing Time 0.027 seconds

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

A Study on an Evaluation Method for Human/System Interface of Advanced Supervisory Control Systems in Nuclear Power Plant (신형 원자력발전소 감시제어체계의 인간/체계 인터페이스 평가 방법에 관한 연구)

  • Lee, Dong-Ha;Im, Hyeon-Gyo;Jeong, Byeong-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.153-169
    • /
    • 1999
  • The design of nuclear control room is advancing toward totally computer based human system interfaces (HSI). Computer based interfaces offer the opportunity to provide improved support of operator performance, but if not properly deployed, can introduce new challenges. This paper reviews the Westinghouse AP-600 Human Factors Verification and Validation Plan selected for HSI evaluation model of Korea next generation nuclear control rooms. The AP-600 HSI evaluation model addressed 15 evaluation issues considering major activity class of operator and task complexity factors. This paper also describes the test procedures experimenters should follow to evaluate the addressed issues.

  • PDF

The Validation Test process and CTE Suitability Evaluation based on IEC-61508 for Improving Safety and Reliability on Unmanned ICT Parcel Storage

  • Myung Sung Kim;Young Min Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.233-243
    • /
    • 2023
  • In modern society, since the expansion of the e-commerce market and the spread of the pandemic, face-to-face business are gradually changing to non-face-to-face. In the logistics industry, the demand for unmanned courier storage is increasing due to lack of loading space from urbanization and courier theft accidents. As the demand for unmanned parcel lockers increases, improved functions such as food storage and efficient space loading are required. This study develops an integrated model-based evaluation procedure of product based on performance factors according to the IEC 61508 standard for newly unmanned parcel storage devices with active loading technology, and derive Critical Technology Element based on the product's core functions and performance goals. As proposing these research, We expect improve the safety and reliability of development targets by identifying and evaluating elements.

Development and Validation of the Korean Traditional Music Ability Test for Young Children (유아국악능력 검사도구 개발 및 양호도 검증)

  • Park, Hyoung-Shin;Kim, Young-Ok
    • Korean Journal of Child Studies
    • /
    • v.28 no.1
    • /
    • pp.37-54
    • /
    • 2007
  • The purpose of this study was the development and validation of a test of young children's understanding and their ability to represent the elements of traditional Korean music. The test was reviewed by professional groups and modified by preliminary testing. In its final form, the Korean Traditional Music Ability Test(KTMAT) for 4- to 6-year-old children consists of 43 items covering understanding and ability to represent Changdan(Changdanhyung, Bak, Bbareugi and Semyeorim) and Garak(Eumjeong and Sikimshae). Item analysis, reliability and validity tests were statistically significant. The KTMAT is an evaluation tool that can be used as basic material for developing children's musical ability, and it can provide valuable information showing direction for children's Korean traditional music education.

  • PDF

A Study on VV&A Application Method for Credibility Improvement of The DM&S for C4I Test and Evaluation (C4I체계 시험평가 국방M&S 신뢰도 향상을 위한 VV&A 적용방안 연구)

  • Kim, Kyung-Hee;Kang, Seok-Joong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1080-1090
    • /
    • 2010
  • A study for improvement of credibility on test & evaluation result of interoperability in battle management information system which focused in C4I systems is very essential in rapid change of battle field environment. Realization of effective operation process with integration of developed IT also core factor for reducing of operational response time such as information gathering from sensor to shooter, time for commander's decision making. Therefore, by required to meet of high technical T&E, meet of complex software's user requirement, long-term system development period, system integration ability's request by various linkage of systems, it is high a M&S dependency to optimal performance, interpoerability's guarantee. Especially credibility on test & evaluation using M&S is very important. This paper will propse a VV&A applied methods using other VV&A case to improve credibility of M&S on test & evaluation.

Development and Validation of the Nurse Needs Satisfaction Scale Based on Maslow's Hierarchy of Needs Theory (Maslow의 욕구위계이론에 근거한 간호사 욕구만족도 측정도구 개발 및 타당화)

  • Kim, Hwa Jin;Shin, Sun Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.6
    • /
    • pp.848-862
    • /
    • 2020
  • Purpose: The purpose of this study was to develop an instrument to evaluate the needs satisfaction of nurses and examine its validity and reliability. Methods: The initial items for the instrument were developed through a literature review and interviews, using the conceptual framework of Maslow's hierarchy of needs theory. The initial items were evaluated for content validity by 14 experts. Four hundred and eighty-six clinical nurses participated in this study through offline and online surveys to test the reliability and validity of the instrument. The first evaluation (n = 256) was used for item analysis and exploratory factor analysis, and the second evaluation (n = 230) was used to conduct a confirmatory factor analysis and to assess the criterion-related validity and internal consistency of the instrument. Test-retest reliability was analyzed using data from 30 nurses. Results: The final instrument consisted of 30 items with two sub-factors for five needs that were identified through the confirmatory factor analysis. The criterion-related validity was established using the five need satisfaction measures (r = .56). Cronbach's α for total items was .90, and test-retest reliability was .89. Conclusion: The findings from this study indicate that this instrument has sufficient validity and reliability. This instrument can be used for the development of nursing interventions to improve the needs satisfaction of clinical nurses.

A Study of Translation Conformity on Korean Version of a Balance Evaluation Systems Test (한국어판 Balance Evaluation Systems Test의 번역 적합성 연구)

  • Jeon, Yong-jin;Kim, Gyoung-mo
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.53-61
    • /
    • 2018
  • Background: The process of language translation, adaptation, and cross-cultural validation of tools for use in multiple countries requires the adoption of well-established, comprehensive, and rigorous methodological approaches. Back translation, which is the most recommended method, permits the detection of errors in the translation and the identification of words or phrases that cannot be accurately or literally translated. Objects: The aim of this study was to verify the content validity of a Korean version of a Balance Evaluation Systems test (BESTest) by using a back-translation method. Methods: This research was conducted in six steps: 1) translation of the BESTest into Korean, 2) evaluation of the translation conformity of Korean-translated BESTest, 3) evaluation of the degree of translation comprehension, 4) back translation of Korean BESTest, 5) evaluation of the technical and conceptual equivalence, and 6) completion of the Korean version of BESTest by the translation verification committee. Results: In this study, Korean version of the BESTest achieved a rating of more than 3 (moderate) for translation comprehension, and technical equivalence and conceptual equivalence of back translation were evaluated as 3 (moderate) or more. Conclusion: The Korean version of the BESTest has proven content validity and is an appropriate tool to measure balance function.

Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph - Nicametate Citrate Tablet, Norfloxacin Capsule (고시 수재 의약품의 용출규격 설정 - 구연산니카메테이트 정, 노르플록사신 캡슐)

  • Kim, Hee-Yun;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Baek, Ji-Yun;Kim, Dong-Sup;Kim, Young-Ok;Sohn, Kyung-Hee;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.362-369
    • /
    • 2010
  • Despite the fact that the dissolution test can serve as an effective tool for drug quality control and prediction of in vivo drug performance, there are a number of drugs with no established dissolution specifications because they were developed quite a long time ago. Under this circumstances, KFDA started the new project that establishes dissolution method and specifications for drugs with no dissolution specifications listed in the Korea Pharmaceutical Codex (KPC). This project aims for promoting the appropriate management of oral solid dosage forms. Seoul regional KFDA selected 2 items, Nicametate citrate tablet and Norfloxacin capsule, for establishing dissolution specifications. We went through the following procedures to develop the dissolution method and specifications: (1) Validation of dissolution test equipment, (2) Purchase of test drugs, (3) Preliminary test with one of the test products (1 lot), (4) Validation of analysis methods (3 lots), (5) Final tests and cross tests among other laboratory to establish dissolution specifications, (6) Additional test with the other test drugs. The outcome of this study will be reflected in revision of the KPC. It is believed that the quality control and evaluation of oral solid dosage forms listed in KPC will be advanced with the revision which adds additional dissolution test and specifications for the drugs with no established dissolution specifications.

Validations of Analysis Methods for Decursin and Decursinol Angelate of Angelicae gigantis Radix by Reversed-Phase Liquid Chromatography

  • Lee, Jong-Pill;Chang, Seung-Yeup;Park, Sang-Yong
    • Natural Product Sciences
    • /
    • v.10 no.6
    • /
    • pp.262-267
    • /
    • 2004
  • A reversed-phase liquid chromatographic method for decursin and decursinol angelate of Angelicae gigantis Radix, an important crude drug in Korean traditional medicine, was developed and validated. Decursin and decursinol angelate, the structure isomer (pyranocoumarin) each other, are the main organic constituents in Angelicae gigantis Radix. This method was developed using a RP-18 column, UV detector at 280 nm and 50% acetonitrile solution containing 0.01 M sodium dodecyl sulfate and 25 mM sodium dihydrogen phosphate (pH 5.0) as the mobile phase. Various validation parameters were included and evaluated satisfactorily. Linearity was established in range 2-75 mg/ml of decursin and decursinol angelate (correlation coefficient = 0.9997 and 0.9995, respectively). This analytical method showed good accuracy (98.1% and 99.5%, respectively). Precision (repeatability) revealed a relative standard deviation value of 1.71% (decursin) and 3.19% (decursinol angelate). For intermediate precision measure the considered variables were equipment and days. A robustness test showing the influence of deferent counter-ion concentration in mobile phase was also performed.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.