• Title/Summary/Keyword: Evaluation Score

Search Result 3,629, Processing Time 0.033 seconds

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

Three-Dimensional Printing of Congenital Heart Disease Models for Cardiac Surgery Simulation: Evaluation of Surgical Skill Improvement among Inexperienced Cardiothoracic Surgeons

  • Ju Gang Nam;Whal Lee;Baren Jeong;Eun-Ah Park;Ji Yeon Lim;Yujin Kwak;Hong-Gook Lim
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.706-713
    • /
    • 2021
  • Objective: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. Materials and Methods: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1-10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. Results: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5-43.5) and 21.4 (17.9-192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2-29.5) and 13.6 (10.3-30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6-17.7) and 8.0 (1.8-170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). Conclusion: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.

Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson's Disease: A Prospective Preliminary Study

  • Lu Yin;Lijuan Du;Yuanzi Li;Yang Xiao;Shiquan Zhang;Huizi Ma;Wen He
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1841-1849
    • /
    • 2021
  • Objective: To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson's disease (PD). Materials and Methods: SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD): 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD: 59.3 ± 6.4 years) during passive ankle rotation. A Young's modulus-ankle angle curve was constructed. The GM slack angle and baseline Young's modulus (E0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. Results: The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of -29.13° ± 3.79° and -25.65° ± 3.39°, respectively, vs. -21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = -0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. Conclusion: The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.

Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI

  • Yu Zhang;Woocheol Kwon;Ho Yun Lee;Sung Min Ko;Sang-Ha Kim;Won-Yeon Lee;Suk Joong Yong;Soon-Hee Jung;Chun Sung Byun;JunHyeok Lee;Honglei Yang;Junhee Han;Jeanne B. Ackman
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.829-839
    • /
    • 2021
  • Objective: To compare the diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3-tesla (3T) magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of visceral pleural surface invasion (VPSI). Visceral pleural invasion by non-small-cell lung cancer (NSCLC) can be classified into two types: PL1 (without VPSI), invasion of the elastic layer of the visceral pleura without reaching the visceral pleural surface, and PL2 (with VPSI), full invasion of the visceral pleura. Materials and Methods: Thirty-three patients with pathologically confirmed VPSI by NSCLC were retrospectively reviewed. Multidetector CT and contrast-enhanced 3T MRI with a free-breathing radial three-dimensional fat-suppressed volumetric interpolated breath-hold examination (VIBE) pulse sequence were compared in terms of the length of contact, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. Supplemental evaluation of the tumor-pleura interface (smooth versus irregular) could only be performed with MRI (not discernible on CT). Results: At the tumor-pleura interface, radial VIBE MRI revealed a smooth margin in 20 of 21 patients without VPSI and an irregular margin in 10 of 12 patients with VPSI, yielding an accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and F-score for VPSI detection of 91%, 83%, 95%, 91%, 91%, and 87%, respectively. The McNemar test and receiver operating characteristics curve analysis revealed no significant differences between the diagnostic accuracies of CT and MRI for evaluating the contact length, angle of mass margin, or arch distance-to-maximum tumor diameter ratio as predictors of VPSI. Conclusion: The diagnostic performance of contrast-enhanced radial T1-weighted gradient-echo 3T MRI and CT were equal in terms of the contact length, angle of mass margin, and arch distance-to-maximum tumor diameter ratio. The advantage of MRI is its clear depiction of the tumor-pleura interface margin, facilitating VPSI detection.

An Analysis of Korean Middle School Student Achievement in Environmental Science in TIMSS 2003 (우리나라 중학생들의 환경 영역 성취도 국제 비교 분석)

  • Jeong, Eun-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.26 no.2
    • /
    • pp.200-211
    • /
    • 2006
  • The purpose of this study was to analyze Korean middle school student achievement in environmental science based on the TIMSS 2003 (Trends in International Mathematics and Science Study), a student comparison of 46 participating nations. Korea ranked the fourth with a mean score of 554 in environmental science. However, all 3 environment science topics assessed in TIMSS are not included in the Korean science curriculum through 8th grade, even though they are included in most other participating nations' curricula. The average percent correct of items was analyzed according to the main topic, the item type and the cognitive domain. Items that showed differences between the average percent correct of Korea and the international average as well as differences between the average percent correct of boys and girls were further analyzed. Results revealed that Korean students performed better than the international average, especially in 'use and conservation of natural resources', multiple-choice items, and items requiring 'factual knowledge'. Also, male students demonstrated significantly higher achievement than female students. On the other hand, Korean students showed relatively lower achievement in constructed-response items, items that contained content they had not learned in science lessons and items requiring descriptions of the uses and effect of science and technology. Moreover, Korean student lacked understanding about acid rain, global warming, and ozone layer destruction. Korean female students showed relatively lower environmental conceptions and lower performance on items requiring data analysis than Korean male students. On the basis of these results, this study suggested that topics of environmental science be included in the science curriculum and taught in the science classroom to help middle school students more fully comprehend environmental issues.

Development of the Cloud Monitoring Program using Machine Learning-based Python Module from the MAAO All-sky Camera Images (기계학습 기반의 파이썬 모듈을 이용한 밀양아리랑우주천문대 전천 영상의 운량 모니터링 프로그램 개발)

  • Gu Lim;Dohyeong Kim;Donghyun Kim;Keun-Hong Park
    • Journal of the Korean earth science society
    • /
    • v.45 no.2
    • /
    • pp.111-120
    • /
    • 2024
  • Cloud coverage is a key factor in determining whether to proceed with observations. In the past, human judgment played an important role in weather evaluation for observations. However, the development of remote and robotic observation has diminished the role of human judgment. Moreover, it is not easy to evaluate weather conditions automatically because of the diverse cloud shapes and their rapid movement. In this paper, we present the development of a cloud monitoring program by applying a machine learning-based Python module "cloudynight" on all-sky camera images obtained at Miryang Arirang Astronomical Observatory (MAAO). The machine learning model was built by training 39,996 subregions divided from 1,212 images with altitude/azimuth angles and extracting 16 feature spaces. For our training model, the F1-score from the validation samples was 0.97, indicating good performance in identifying clouds in the all-sky image. As a result, this program calculates "Cloudiness" as the ratio of the number of total subregions to the number of subregions predicted to be covered by clouds. In the robotic observation, we set a policy that allows the telescope system to halt the observation when the "Cloudiness" exceeds 0.6 during the last 30 minutes. Following this policy, we found that there were no improper halts in the telescope system due to incorrect program decisions. We expect that robotic observation with the 0.7 m telescope at MAAO can be successfully operated using the cloud monitoring program.

[RETRACTED] Changes in the volatile aromatic compounds and amino acid contents of distilled soju using co-fermentation by Saccharomyces cerevisiae and Hanseniaspora uvarum yeasts ([논문철회] Saccharomyces cerevisiae 와 Hanseniaspora uvarum 효모 혼합발효를 이용한 증류식 소주의 휘발성 향기성분 및 아미노산 함량 변화)

  • Kyu-Taek Choi;Chun-Woo Park;Su-Hyun Lee;Ye-Na Lee;Ji-Yun Oh;Jun-Su Choi;Deokyeong Choe;Sae-Byuk Lee
    • Food Science and Preservation
    • /
    • v.30 no.6
    • /
    • pp.1029-1042
    • /
    • 2023
  • This study aimed to apply the technology of increasing the volatile aromatic compounds in wine through mixed fermentation of Saccharomyces cerevisiae and non-Saccharomyces yeasts to make distilled soju. The expectation was to induce changes in metabolites such as volatile aromatic compounds before the distillation process, followed by concentrating these compounds through distillation to enhance the odor property of distilled soju. Additionally, the study aimed to examine the impact of mixed fermentation with S. cerevisiae and non-Saccharomyces yeasts on distilled soju's free amino acid content. As a result, when Hanseniaspora uvarum yeast was used, there was an increase in the content of low molecular weight volatile aroma compounds, particularly esters. Distilled soju co-fermented with S. cerevisiae and H. uvarum SJ69 exhibited similar amino acid content to distilled soju single-fermented with S. cerevisiae. However, distilled soju co-fermented with S. cerevisiae and H. uvarum S6, a decrease in amino acid content. Sensory evaluation results indicated a higher odor score in distilled soju co-fermented with S. cerevisiae and H. uvarum S6, suggesting that the mixed fermentation technology utilizing H. uvarum could contribute to improving the quality of distilled soju in the future.

A Study on the Characteristics of Academic Achievement in Problem Solving and Inquiry Tasks of Korean Fourth Graders in TIMSS 2019 (TIMSS 2019 문제해결 및 탐구 과제에 대한 우리나라 초등학교 4학년 학생들의 학업성취 특성 분석)

  • Jeom-Rae Kwon
    • Journal of Science Education
    • /
    • v.48 no.1
    • /
    • pp.31-46
    • /
    • 2024
  • This study analyzes the academic achievement characteristics of Korean fourth graders on the problem solving and inquiry tasks (PSIs) introduced in TIMSS 2019. TIMSS 2019 conducted a computer-based assessment in addition to the traditional paper-based assessment. The PSIs were included only in the computer-based assessment, so 30 countries participated in the PSIs of the computer-based assessment. PSIs consist of integrating multiple content and cognitive domains, including 10 or fewer items. Most of the items are constructed in an open-ended format rather than multiple-choice. The analysis results showed that there were differences in student achievement across countries depending on the inclusion of PSIs. Korea's average achievement score decreased by 1 point. The analysis of individual items showed that students' achievement was somewhat low, and the correct answer rate for male students was generally higher than that for female students in many items. Furthermore, item-by-item analysis revealed that there were items where countries such as England and Finland had higher correct answer rates than traditional high-achieving countries, i.e. Singapore, Taiwan, and Korea. Considering the recent emphasis on integrated education, it seems necessary to review the use of PSIs in assessments in Korea as well.

Evaluation of the Confidence and Learning Effects of Dental Hygiene Ethical Decision-Making through Dental Hygiene Ethics Subjects (치위생(학)과 학생들의 치위생윤리 교과목을 통한 치위생 윤리적 의사결정에 대한 자신감과 학습성과 평가)

  • Jung-Hui Son;Sun-Jung Shin
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.91-100
    • /
    • 2023
  • Background: This study evaluated the learning outcomes of dental hygiene students' ethical consciousness and ethical decision-making competence through dental ethics courses conducted in some universities. Methods: The subjects were 35 and 29 fourth-year dental hygiene students at G University in the first semester of 2021 and 2022, respectively, and 53 and 43 third-year dental hygiene students at D University, respectively, for a total of 160 students. After implementing the dental hygiene ethics course, classroom performance was evaluated in terms of moral sensitivity, confidence in making ethical decisions, classroom practicality, learning outcomes, and class satisfaction. Statistical analysis was conducted using independent t-test and paired t-test, and the statistical significance level was 0.05. Results: Both universities reported an increase in moral sensitivity and confidence in ethical decision-making after the course (p<0.001). Classroom practicality and class satisfaction for the dental hygiene ethics course did not differ between disciplines and were rated positively with a score of 4 or higher (p>0.05). Learning outcomes were higher among 4-year students than 3-year students (p<0.001). Conclusions: It was evaluated that the ethics in dental hygiene curriculum can strengthen students' competence in ethical decision-making, including moral sensitivity and confidence in solving ethical problems in dental hygiene.

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.