• Title/Summary/Keyword: Evaluating Tool

Search Result 841, Processing Time 0.034 seconds

Comparison of the Role of CT and Fiberoptic Bronchoscopy in the Diagnosis of Hemoptysis (객혈 진단을 위한 CT와 가관지경의 역할 비교)

  • Choe, Kyu-Ok;Kim, Hyun-Sook;Hong, Young-Kook;Seo, Jae-Seong;Ryu, Jeong-Ah;Yang, Dong-Gyoo;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.209-217
    • /
    • 1999
  • Backgrounds: To investigate the role of CT as a screening tool and to compare the diagnostic accuracy with that of the fiberoptic bronchoscopy (FOB) in evaluating the causes of hemoptysis. Methods: The retrospective review of plain chest radiograph, CT and FOB was done in 72 patients with hemoptysis. The diagnosis were confirmed by histology (n=33), bacterial culture (n=6), cytology (n=3), serology (n=2), skin test (n= 1), clinical response (n=5), and airway disease mainly by HRCT (n=22). Results: The causes of hemoptysis were shown to be lung cancer (n=29), bronchiectasis (n=19), tuberculosis (n=12), aspergilloma (n=5), invasive aspergillosis (n=l), COPD (n=3) and others (n=3). The sensitivity was 100% and 91,7% by CT and FOB respectively. The diagnostic compatibility was 95.8% and 59.7% by CT and FOB respectively. The diagnostic compatibility in cases with central airway disease was 96.3% and 100 % in CT and FOB. In parenchymal disease, CT and FOB showed 91.3 % and 43.5 % of compatibility, respectively. airway disease, CT and FOB showed 100% and 31.8% compatibility, respectively. That is to say, CT has higher sensitivity and diagnostic compatibility than FOB for identifying the causes of hemoptysis, and is more helpful for patients with hemoptysis from parenchymal or airway disease. FOB had the advantage in obtaining histologic, cytologic and bacteriologic diagnosis with biopsy or washing Conclusion: CT should be used as the screening method before performing FOB for patients with hemoptysis who have normal or nonspecific findings or peripheral airway disease in plain chest radiograph.

  • PDF

Reticulocyte hemoglobin content for the diagnosis of iron deficiency in young children with acute infection (급성 감염성 질환을 가진 영유아에서 철결핍 진단 지표로서의 망상적혈구혈색소량)

  • Kim, Jon Soo;Choi, Jun Seok;Choi, Doo Young;You, Chur Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.827-833
    • /
    • 2008
  • Purpose : Early identification of iron deficiency in young children is essential to prevent damaging long-term consequences. It is often difficult for the pediatrician to know which indices should be used when diagnosing these conditions especially in hospitalized young children. This study investigated the clinical significances of reticulocyte hemoglobin content in young children with acute infection. Methods : We studied 69 young children aged from 6 to 24 months admitted with acute infection in a single center. Venous blood was drawn to determine hemoglobin (Hb), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), hemoglobin content (CH), reticulocyte hemoglobin content (CHr), and red blood cell distribution width (RDW) using ADVIA 120 (Bayer Diagnostics, NY, USA). For evaluating iron status, iron, total iron binding capacity, ferritin and transferrin saturation (Tfsat) were determined. Iron deficiency was defined as Tfsat less than 20%, and iron deficiency anemia as Tfsat less than 20% and Hb level less than 11 g/dL. Results : In all, 47 were iron deficient; 17 of these had iron deficiency anemia. CHr was the only significant predictor of iron deficiency (likelihood ratio test=71.25; odds ratio=0.67; P<0.05). Plasma ferritin level had no predictive value (P=0.519). Subjects with CHr less than 27.4 pg had lower Hb level, MCH, CH, Tfsat, and iron levels than those with CHr 27.4 pg or more (P<0.05 for all). Conclusion : CHr level was a sensitive screening tool and the strongest predictor of iron deficiency in hospitalized infants with acute infection; it was cost saving and avoiding additional sampling. However its reference range should be established.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF

Frequency of Micronuclei in Lymphocytes Following Gamma and Fast-neutron Irradiations (방사선 조사량에 따른 인체 정상 림파구의 미세핵 발생빈도)

  • Kim Sung-Ho;Cho Chul-Koo;Kim Tae-Hwan;Chung In-Yong;Yoo Seong-Yul;Koh Kyoung-Hwan;Yun Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 1993
  • The dose response of the number of micronuclei in cytokinesis-blocked (CB) lymphocytes after in vitro irradiation with $\gamma$-rays and neutrons in the 5 dose ranges was studied for a heterogeneous population of 4 donors. One thousand binucleated cells were systematically scored for micronuclei. Measurements performed after irradiation showed a dose-dependent increase in micronuclei (MN) frequency in each of the donors studied. The dose-response curves were analyzed by a linear-quadratic model, frequencies per 1000 CB cells were ($0.31{\pm}0.049$)D+($0.0022{\pm}0.0002)D^2+(13.19{\pm}1.854) (r^2=1.000,\;X^2=0.7074,\;p=0.95$) following $\gamma$ irradiation, and ($0.99{\pm}0.528$)\;D+(0.0093{\pm}0.0047)\;D^2+(13.31{\pm}7.309)\;(r^2=0.996,\;X^2=7.6834,\;p=0.11) following neutrons irradiation (D is irradiation dose in cGy). The relative biological effectiveness (RBE) of neutrons compared with $\gamma$-rays was estimated by best fitting linear-quadratic model. In the micronuclei frequency between 0.05 and 0.8 per cell, the RBE of neutrons was $2.37{\pm}0.17$. Since the MN assay is simple and rapid, it may be a good tool for evaluating the $\gamma$-ray and neutron response.

  • PDF

Modification of WASP5 for Ungauged Watershed Management and Its Application (미계측 유역관리를 위한 WASP5 모형의 개선 및 적용성 검토)

  • Kim, Jin-Ho;Shin, Dong-Suk;Kwun, Soon-Kuk
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • This study was carried out to develop a water quality simulation model for the evaluation of an ungauged watershed. For this purpose, the WASP5 model was selected and modified. The model consists of three sub-models, LOAD-M, DYN-M, and EUT-M. LOAD-M, an empirical model, estimates runoff loadings using point and non-point source data of villages. The Geum River Estuary watershed was selected to calibrate and verify the Modified-WASP5. The LOAD-M model was established using field data of water quality and quantity at the gauging stations of the watershed and was applied to the ungauged watersheds, taking the watershed properties into consideration. The result of water quality simulation using Modified-WASP5 shows that the observed average BOD data from Gongju and Ganggyeong were 2.6 mg/L and 2.8 mg/L, and the simulated data were 2.5 mg/L and 2.4 mg/L, respectively. Generally, simulation results were in good agreement with the observed data. This study focused on formulating an integrated model for evaluating ungauged watersheds. Even though simulation results varied slightly due to limited availability of data, the model developed in this study would be a useful tool for the assessment and management of ungauged watersheds.

A Criteria on Nitrate Concentration in Soil Solution and Leaf Petiole Juice for Fertigation of Cucumber (Cucumis sativus L.) under Greenhouse Cultivation (시설 오이의 관비재배를 위한 토양용액과 엽병즙액중 질산태 농도 기준 설정)

  • Lim, Jae-Hyun;Lee, In-Bog;Kim, Hong-Lim
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2001
  • To develope a technique for efficiently managing fertilizer for cucumber, a quick test method to quantify nitrate content in soil solution and leaf petiole juice using a simple instrument was investigated. Among the nitrate analyzing instruments such as compact ion meter, nitrate ion meter, and test strip with reflectometer, the paper test-strip used in conjunction with a hand-held reflectometer was most closely correlated with ion chromatography method in nitrate content, and then it would be suggested with a tool that a farmer can use rapidly, conveniently and accurately for nitrate analysis in a field. Nitrate content in soil solution collected by porous cup was very variable on the lapsed time after drip irrigation and the sampling positions such as soil depth and the distance from dripper. As a result, a significant correlation between nitrate contents of soil solutions and 2M KCl soil extract was not found. However, nitrate content in soil solution extracted with a volume basis (soil:water=1:2) showed the highly significant correlation with that in 2M KCl extract. Nitrate contents of cucumber leaf petiole juices was greatly different between upper and lower leaves. Eleven to sixteen positioned-leaf would be a proper sampling position to determine nitrate content in leaf petiole for evaluating nutrient state by plant tissue analysis. From the secondary regression equations between nitrate contents of soil and petiole juice and the yield of cucumber, nitrate levels for real time diagnosis were estimated as $400mg\;l^{-1}$ soil solution by porous cup. $300mg\;l^{-1}$ in a soil volume extraction, and $1400mg\;l^{-1}$ in petiole juice from spring to summer season. In addition, the maximum yield of cucumber fruit in pot test was obtained in nitrate $1500mg\;l^{-1}$ level of petiole juice, which was similar to nitrate $1400mg\;l^{-1}$ in greenhouse trial.

  • PDF

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Evaluation on Climate Change Vulnerability of Korea National Parks (국립공원의 기후변화 취약성 평가)

  • Kim, Chong-Chun;Kim, Tae-Geun
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.1
    • /
    • pp.42-50
    • /
    • 2016
  • The purpose of this study is to set the direction to manage national parks to cope with climate change, and offer basic data to establish the relevant policies. Towards this end, this study analyzed the current and future climate change vulnerability of national parks using the 24 proxy variables of vulnerability in the LCCGIS program, a tool to evaluate climate change vulnerability developed by the National Institute of Environmental Research. To analyze and evaluate the current status of and future prospect on climate change vulnerability of national parks, the proxy variable value of climate exposure was calculated by making a GIS spatial thematic map with $1km{\times}1km$ grid unit through the application of climate change scenario (RCP8.5). The values of proxy variables of sensitivity and adaptation capability were calculated using the basic statistics of national parks. The values of three vulnerability evaluation items were calculated regarding the present (2010s) and future (2050s). The current values were applied to the future equally under the assumption that the current state of the proxy variables related to sensitivity and adaptation capability without a future prediction scenario continues. Seoraksan, Odaesan, Jirisan and Chiaksan National Parks are relatively bigger in terms of the current (2010s) climate exposure. The national park, where the variation of heat wave is the biggest is Wolchulsan National Park. The biggest variation of drought occurs to Gyeryongsan National Park, and Woraksan National Park has the biggest variation of heavy rain. Concerning the climate change sensitivity of national parks, Jirisan National Park is the most sensitive, and adaptation capability is evaluated to be the highest. Gayasan National Park's sensitivity is the lowest, and Chiaksan National Park is the lowest in adaptation capability. As for climate change vulnerability, Seoraksan, Odaesan, Chiaksan and Deogyusan National Parks and Hallyeohaesang National Park are evaluated as high at the current period. The national parks, where future vulnerability change is projected to be the biggest, are Jirisan, Woraksan, Chiaksan and Sobaeksan National Parks in the order. Because such items evaluating the climate change vulnerability of national parks as climate exposure, sensitivity and adaptation capability show relative differences according to national parks' local climate environment, it will be necessary to devise the adaptation measures reflecting the local climate environmental characteristics of national parks, rather than establishing uniform adaptation measures targeting all national parks. The results of this study that evaluated climate change vulnerability using climate exposure, sensitivity and adaptation capability targeting Korea's national parks are expected to be used as basic data for the establishment of measures to adapt to climate change in consideration of national parks' local climate environmental characteristics. However, this study analyzed using only the proxy variables presented by LCCGIS program under the situation that few studies on the evaluation of climate change vulnerability of national parks are found, and therefore this study may not reflect overall national parks' environment properly. A further study on setting weights together with an objective review on more proper proxy variables needs to be carried out in order to evaluate the climate change vulnerability of national parks.

A Study on the Distinct Element Modelling of Jointed Rock Masses Considering Geometrical and Mechanical Properties of Joints (절리의 기하학적 특성과 역학적 특성을 고려한 절리암반의 개별요소모델링에 관한 연구)

  • Jang, Seok-Bu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1998.05a
    • /
    • pp.35-81
    • /
    • 1998
  • Distinct Element Method(DEM) has a great advantage to model the discontinuous behaviour of jointed rock masses such as rotation, sliding, and separation of rock blocks. Geometrical data of joints by a field monitoring is not enough to model the jointed rock mass though the results of DE analysis for the jointed rock mass is most sensitive to the distributional properties of joints. Also, it is important to use a properly joint law in evaluating the stability of a jointed rock mass because the joint is considered as the contact between blocks in DEM. In this study, a stochastic modelling technique is developed and the dilatant rock joint is numerically modelled in order to consider th geometrical and mechanical properties of joints in DE analysis. The stochastic modelling technique provides a assemblage of rock blocks by reproducing the joint distribution from insufficient joint data. Numerical Modelling of joint dilatancy in a edge-edge contact of DEM enable to consider not only mechanical properties but also various boundary conditions of joint. Preprocess Procedure for a stochastic DE model is composed of a statistical process of raw data of joints, a joint generation, and a block boundary generation. This stochastic DE model is used to analyze the effect of deviations of geometrical joint parameters on .the behaviour of jointed rock masses. This modelling method may be one tool for the consistency of DE analysis because it keeps the objectivity of the numerical model. In the joint constitutive law with a dilatancy, the normal and shear behaviour of a joint are fully coupled due to dilatation. It is easy to quantify the input Parameters used in the joint law from laboratory tests. The boundary effect on the behaviour of a joint is verified from shear tests under CNL and CNS using the numerical model of a single joint. The numerical model developed is applied to jointed rock masses to evaluate the effect of joint dilation on tunnel stability.

  • PDF

Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis (결핵 진단에서 ICT Tuberculosis Test Kit의 효용성)

  • Chang, Chul-Hun;Son, Han-Chul;Ryu, Ki-Chan;Park, Soon-Kew;Lee, Seon-Ho;Kim, Sung-Ryul;Park, Ki-Hyung;Kim, Woo-Seok;Koo, Kyong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 1999
  • Background: Early diagnosis of tuberculosis is critical, especially in Korea, an area where tuberculosis is endemic. Because antibody responses to some membrane proteins of Mycobacterium tuberculosis are not comparable, and the policy of BCG vaccination and the prevalence of tuberculosis are different from country to country, the usefulness of the serological diagnostic tests is questionable in Korea, even though they have been confirmed to be useful in other countries. In the specific context of Korea, we tried to evaluate the validity of the ICT Tuberculosis Test (ICT), a membrane-based antibody kit that purports to detect the 5 M. tuberculosis complex-specific antigens including 38-kDa protein. Method: 68 patients with tuberculosis were tested : 37 had no history of previous tuberculosis, and 31 were reactivated cases. The control group comprised 77 subjects : 25 healthy adults, 35 hospital workers with frequent contact with tuberculosis patients, and 17 in-patients with non-tuberculous respiratory diseases. Results: The diagnostic sensitivities of the ICT were 87% and 73% in patients with versus without previous history of tuberculosis, respectively. The sensitivities of smear-positive and smear-negative patient groups were 81% and 73%, respectively. Both of the two patients with extrapulmonary tuberculosis tested positive through the ICT. The specificities of the ICT were 88%, 94%, and 94% in healthy adults, hospital workers, and non-tuberculous patients, respectively, with an overall specificity of 92%. Conclusion: It is suggested that when combined with traditional techniques, the ICT is an useful tool for the diagnosis of pulmonary tuberculosis. The procedure is simple, easy to perform, rapid, and needs no equipment. It shows 73% sensitivity and 92% specificity for the diagnosis of tuberculosis.

  • PDF