• Title/Summary/Keyword: Evacuation regulations

Search Result 44, Processing Time 0.023 seconds

Development of Rule-based Checking Modules for the Evacuation Regulations of Super-tall Buildings in Open BIM Environments (개방형BIM환경에서의 룰기반 초고층건축물 피난법규 검토모듈 개발)

  • Kim, Inhan;Choi, Jungsik;Cho, Geunha
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2013
  • IFC based open BIM has internationally developed as a solution for interoperability problem among different software applications. Despite much interest and effort, the open BIM technologies are rarely introduced to the construction industry and need more technical development for a practical application as well. This research aims to develop automated code checking modules for quality assurance process of BIM data. The research have analyzed domestic regulations focusing on super-tall buildings and developed open BIM-based code checking modules for the evacuation regulations. The modules are able to validate evacuation regulations such as installation of emergency elevator and fire safety zone. The authors expect to improve the process of BIM quality assurance and enhance the quality of BIM data by this research on automated checking system.

A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

A Study on the Evacuation Performance According to Variation in Remoteness between Exit Stairways in Tall Buildings

  • Han, Gisung;Kim, Tae-Young;Lee, Kyung-Hoon
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.53-61
    • /
    • 2020
  • The purpose of this study is to examine the influence of remoteness between exit stairways on evacuation performance. Firstly, we reviewed the design regulations of the U.S., the U.K., and South Korea, in relation to remoteness between Exit stairways. Secondly, evacuation simulation was implemented, in order to evaluate the adequacy of each standard. Eight tall buildings in South Korea were selected for the simulation. Evacuation performance was assessed for different remote distances between Exit stairways. Lastly, this research analyses the evacuation simulation data statistically in relation to the effect of remoteness on evacuation time. We found that as the distance between two exit stairways increases, the total evacuation time and average evacuation time for evacuees decreases. There was no statistical influence between the maximum travel distance of the evacuee and the remoteness between two exit stairways, but there was a significant effect on the average travel distance of the evacuees. In addition, the results from the optimal point showed that the L_ratio had the highest evacuation time at 0.44, while the D_ratio had the highest evacuation time at 0.38.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

A Basic Study on the Evacuation Safety Performance of High-rise Apartment Building (고층 공동주택의 피난성능에 관한 기초적 연구)

  • 이용재
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2001
  • It has been recognized that the evacuation planning is very important for effective evacuation of occupants on fire event. However the present evacuation planning and regulation for fire safety usually tend to meet the minimum requirements based on the existing laws and regulations. The ultimate goal of the evacuation planning is evacuate occupants rapidly from building fires to the safe areas. In this study, First, analyzed occupants load density and occupants characteristics in high-rise apartment buildings, Second, A evacuation safety performance of high-rise apartment buildings was analyzed with various typical floor plans. The purpose of this study is to figure out the evacuation characteristics in high-rise apartment buildings and improve countermeasure through comparative study on the Evacuation regulation and floor plans for High-rise Apartment buildings.

  • PDF

A Study on the Major Standards and Actual Conditions of Evacuation Safety in Child Care Facility (보육시설의 피난안전 관련 주요 기준 분석 및 실태조사에 관한 연구)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2009
  • Recently, the number of child care facility and social demand for high quality child care service increase suddenly. Especially, social atmosphere about fire safety is more sensitive in Korea. The majority of the residents in a child care facility are composed of early childhood having difficulty to evacuate, and therefore the number of stories of a building and the appropriateness of a evacuation equipment play an important role in the evacuation safety. In this study, problems and improvements for the evacuation safety are dealt with the present conditions of child care facilities, the comparative analysis between domestic and foreign standards, the research on the actual condition of evacuation equipments, and so on. The study brings to a conclusion that it is necessary to systematize the regulations regarding fire safety, to connect fire-fighting facilities for design standards and operations of emergency preparation equipments, to improve the regulations for fire protection system such as the sprinkler system, and to restrict the facilities having fire hazards.

A Study on the Crew's Survival ratio according to ship's construction (선박구조가 승무원 생존율에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.10a
    • /
    • pp.50-51
    • /
    • 2009
  • This paper aims to improve survival ratio at ship fires by soot density reduction This study examines soot density and visibility using FDS. And also examines evacuation time by Pathfinder. The FDS(Fire Dynamic Simulator) is a 3 zone model(Field Model) analysis tool and the patherfinder is a useful analysis tool for evacuation. This research examined about evacuation time using the current regulations of the ship's corridor width and exit width first And then studied evacuation time again when ship's structure was changed according to the method that is proposed in this paper. And finally compared the results each other.

  • PDF

The Applicability Analysis of Life Safety Codes for High Fire Risk Building Applications (화재 위험성을 중심으로 한 건축물 용도별 한국형인명안전기준의 적용성 검토에 관한 연구)

  • Koo, In-hyuk;Kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.103-104
    • /
    • 2022
  • In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. In particular, calculation of evacuation capacity in evacuation safety design of buildings is the most important factor that directly affects evacuation safety performance. However domestic standards is not consider about occupant characteristics. also the case of domestic, it has the problem that the law is partially applied when the fire safety design of buildings. Therefore, the purpose of this study is to study the current status and related regulations of the life safety code for the application of high fire risk buildings, and to analyze the difference in evacuation time through Case Study.

  • PDF

A Study on Improvement of Evacuation Safety at Daycare Center (어린이집 피난안전 향상에 관한 연구)

  • Jin, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.63-73
    • /
    • 2017
  • As more and more the number of a couple working together for living has increased and an interest in early education has risen, daycare centers have made an effort to provide effective and good service beyond 'nursery care'. The most important thing in building in the event of disasters is safe evacuation of occupants. Having 'safe evacuation route' is required to reduce damage caused by disasters, It is necessary to give continuous and repeated training for right evacuation to infant and children so that they can evacuation successfully. This study examined problems that need improvement so that evacuation instrument installed in daycare centers can be used better by analyzing a survey of evacuation related facilities on daycare centers. This study found that laws and regulations on safety should be improved, evacuation facilities prepared against should be maintained regularly by relevant authorities, training for coping with disasters should be provied and evacuation instruments which are suitable for children.