• Title/Summary/Keyword: Evacuation measure

Search Result 47, Processing Time 0.025 seconds

A Study on the Visibility Measurement of CCTV Video for Fire Evacuation Guidance (화재피난유도를 위한 CCTV 영상 가시도 측정에 관한 연구)

  • Yu, Young-Jung;Moon, Sang-Ho;Park, Seong-Ho;Lee, Chul-Gyoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.947-954
    • /
    • 2017
  • In case of a fire in urban large structures such as super high-rise buildings, evacuation guidance must be provided to the occupants in order to minimize human deaths and injuries. Therefore, it is essential to provide emergency evacuation guidance when a major fire occurs. In order to effectively support evacuation guidance, it is important to identify major items such as fire location, occupant position, escape route, etc. Also, it is important to quickly identify evacuation areas where residents can safely evacuate from a fire. In this paper, we analyze the CCTV video and propose a method of measuring visibility of the evacuation zone from the smoke caused by the fire in order to determine the safety of evacuation area. To do this, we first extract the background video from the smoke video to measure the visibility of the specific area due to smoke. After generating an edge-extracted image for the extracted background video, the degree of visibility is measured by calculating the change in the edge strength due to smoke.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

The Spatial Location Analysis of Disaster Evacuation Shelter for Considering Resistance of Road Slope and Difference of Walking Speed by Age - Case Study of Seoul, Korea (도로경사와 연령별 보행속도 차이를 고려한 자연재난 대피소의 입지분석 - 서울시 사례분석)

  • Lee, So Hee;Goo, Sin Hoi;Chun, Young Woo;Park, Young Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.69-77
    • /
    • 2015
  • In Korea, local governments have decided the location of shelters as part of their disaster planning. However, no quantitative standards, such as assuming different hazard and shelter types, shelters' capacity, are specified in that planning. To propose the direction of disaster evacuation policy, first of all, the current state of shelters' location and evacuation area is needed to be analyzed. In addition, considering topographical condition such as road slope and physical strength by age are important factors to measure optimal evacuation route. The purpose is to suggest a new methodology of estimating optimal evacuation route considering resistance of road slope and difference of walking speed by age. Moreover, as a case study of Seoul, Korea, using coverage analysis of GIS analysis tool, the accessible area (or vulnerable area) to the shelters is evaluated based on the spatial distribution of disaster evacuation shelters and their accommodation capacity, according to evacuation time within 7.5, 15 and 30 minutes. The main results are summarized as follows: 1) The average area of disaster evacuation shelter per person is calculated as 0.45 square meters. Considering that the minimum shelters' area per person is 1 square meters, only 45% of people in Seoul can be accommodated. 2) The ratio of inhabitants who live in accessible area within 7.5 minutes presents only 33% of all. Furthermore, the ratio of inhabitants by age group of 5~9 or over 65 years old shows significantly lower percentage in comparison with 15~49 years old people.

A Study on the Optimized Announcement Based Evacuation Guidance Using Haas Effect (선행음 효과를 이용한 최적의 음성피난유도음에 관한 연구)

  • Baek, Eun-Sun;Kim, Sun-Woo;Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Kook, Chan
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • In case of an emergency such as a fire on a building and there is a need to evacuate the occupant in that building, it is important to have the guidance information effectively delivered to the evacuating occupants to guide them toward a safe direction using audio sensual media. And, it is also very important to prevent the evacuating occupants getting lost or falling astray, away from the direction toward safety. The purpose of this study, in this respect, is to examine the possible application of the precedent sound effect, with which the evacuating occupants may get a sense of the direction where the announcement comes from. With such an effect, an experiment was conducted to measure the extent to which people can hear the preceding and the following sound in terms of the acoustic pressure level changes and delay time changes, with a view to make the optimal evacuation-guidance announcement or sound. The optimal evacuation guidance sound (announcement) per each of the experimental indoors environments were as follows; 1) Regarding the optimal condition for the evacuation guidance announcement sound in the space of a lecture room, the direction of the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~50 ms in comparison with the advanced sound or when there is no difference between the acoustic pressures of the advanced and follow-up sounds or the acoustic pressure of the advanced sound is higher than that of the follow-up sound. 2) Regarding the optimal evacuation guidance announcement sound in the space of a hall, the advanced sound is positively recognized when the follow-up sound has the delaying time of 20 ms~60 ms in comparison with the advanced sound. 3) Regarding the optimal evacuation guidance announcement sound in the space of a gymnasium, the advanced sound is positively recognized when the follow-up sound has the delaying time of 10 ms~40 ms in comparison with the advanced sound or when the sound pressure of the advanced sound has a higher level than or the same level as that of the follow-up sound.

Stack Effect Mitigation Methods in Exit Route of High-rise Building (고층 건축물 피난경로의 연돌효과 저감 방안)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.284-288
    • /
    • 2010
  • Length of staircase get longer and evacuation load get heavier in proportion to the building height. Therefore evacuation time could be considered proportional to square of building height. While smoke spreads vertically so rapidly, evacuation speed is too slow, therefore the reasonable measure for the safe of egress route is urgent. Existing pressurizing smoke control system of vertical exit route is seriously limited in function under the stack effect in winter. Stack effect in winter could be overcome with the methods of opening the staircase outward or letting airflow be free between staircase and outside.

  • PDF

A Study on the Indoor Location Determination using Smartphone Sensor Data For Emergency Evacuation (스마트폰 센서 데이터를 이용한 실내 응급대피용 위치 추정 연구)

  • Quan, Yu;Jang, Jung-Hwan;Jin, Hye-Myeong;Jho, Yong-Chul;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.51-58
    • /
    • 2019
  • The LBS(Location Based Service) technology plays an important role in reducing wastes of time, losses of human lives and economic losses by detecting the user's location in order by suggesting the optimal evacuation route of the users in case of safety accidents. We developed an algorithm to estimate indoor location, movement path and indoor location changes of smart phone users based on the built-in sensors of smartphones and the dead-reckoning algorithm for pedestrians without a connection with smart devices such as Wi-Fi and Bluetooth. Furthermore, seven different indoor movement scenarios were selected to measure the performance of this algorithm and the accuracy of the indoor location estimation was measured by comparing the actual movement route and the algorithm results of the experimenter(pedestrian) who performed the indoor movement. The experimental result showed that this algorithm had an average accuracy of 95.0%.

Customized Evacuation Pathfinding through WSN-Based Monitoring in Fire Scenarios (WSN 기반 화재 상황 모니터링을 통한 대피 경로 도출 알고리즘)

  • Yoon, JinYi;Jin, YeonJin;Park, So-Yeon;Lee, HyungJune
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1661-1670
    • /
    • 2016
  • In this paper, we present a risk prediction system and customized evacuation pathfinding algorithm in fire scenarios. For the risk prediction, we apply a multi-level clustering mechanism using collected temperature at sensor nodes throughout the network in order to predict the temperature at the time that users actually evacuate. Based on the predicted temperature and its reliability, we suggest an evacuation pathfinding algorithm that finds a suitable evacuation path from a user's current location to the safest exit. Simulation results based on FDS(Fire Dynamics Simulator) of NIST for a wireless sensor network consisting of 47 stationary nodes for 1436.41 seconds show that our proposed prediction system achieves a higher accuracy by a factor of 1.48. Particularly for nodes in the most reliable group, it improves the accuracy by a factor of up to 4.21. Also, the customized evacuation pathfinding based on our prediction algorithm performs closely with that of the ground-truth temperature in terms of the ratio of safe nodes on the selected path, while outperforming the shortest-path evacuation with a factor of up to 12% in terms of a safety measure.

A Study on the Fingerprint Location Determination using Smartphone Geomagnetic Data For Emergency Evacuation (지자기데이터를 이용한 응급대피용 핑거프린트 위치 추정에 관한 연구)

  • Jin, Hye-Myeong;Jang, Jung-Hwan;Jang, Jing-Lun;Jho, Yong-chul;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.59-65
    • /
    • 2019
  • The Location Based Service is growing rapidly nowadays due to the universalization of the use for smartphone, therefore the location determination technology has been placed in an important position. This study suggests a method that can provide the estimate of users' location by using PDR method and smartphone geomagnetic sensor data. This method assists the measure of enhancing the accuracy of indoor localization. Moreover, it is to study ways to provide the exact indoor layout for evacuating the workers in emergency such as fires and natural disasters.

A Study on Fire Prevention Requirements and Tests for Small Aircraft (소형항공기의 화재방지 요건 및 시험에 관한 연구)

  • Yoo, Seung-Woo;Jin, Young-Kwon
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • The goal of fire prevention research is to eliminate fires as a cause of fatal accidents and there are two main areas of research. One is to prevent flame propagation during in-flight and it addresses fire hazards. The other is to minimize the possibility of flame penetration or fuselage burn-through and it aims toward post-crash survival include crash protection, emergency evacuation and post-evacuation survival. Civil aviation authorities world-wide are trying to identify threats and measure performance for fire prevention. The results of research are standardized and given as general directions of test methods. This paper has prepared to study and present the means of compliance to the fire prevention requirements and applicable test methods.

Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam - (기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로-)

  • Kim, Hyun-Tae;Kim, Won-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.