Analyses of Scenarios Based on a Leakage of Highly Compressed Air and Fire Anticipated in CAES (Compressed Air Energy Storage) Facility (압축공기에너지저장 시설에서 발생 가능한 압축공기 유출 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.568-576
    • /
    • 2015
  • In this study, scenarios based on the leakage of highly compressed air and fire occurrence turned out to be high risks in an operation stage of CAES facility were constructed and estimated. By combining Bernoulli equation with momentum equation, an expression to calculate an impact force of a jet flow of compressed air was derived. An impact force was found to be proportional to the square of diameter of fracture and the pressure of compressed air. Four types of fire scenarios were composed to evaluate an effects that seasonal change and location of fire source have on the spread behavior of smoke. Smoke from the fire ignited in the vicinity of CAES opening descended more quickly below the limit line of breathing than one from the fire occurred 10 m away from CAES opening, which is expected to occur due to a propagation of wave front of smoke. It was shown that a rate of smoke spread of the winter fire is faster than one of the summer fire and smoke from the winter fire spreads farther than one of the summer fire, which are dependent on the direction of air flow into access opening. Evacuation simulation indicated that the required safe evacuation time(RSET) of the summer and winter fires are 262, 670 s each.

Development of distributed inundation routing method using SIMOD method (SIMOD 기법을 이용한 분포형 침수 추적 기법 개발)

  • Lee, Suk Ho;Lee, Dong Seop;Kim, Jin Man;Kim, Byung Sik
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.579-588
    • /
    • 2016
  • Changes in precipitation due to climate change is made to induce the local and intensive rainfall, it is increasing damage caused by inland inundation. Therefore, it requires a technique for predicting damage caused by flooding. In this study, in order to determine whether this flood inundated by any route when the levee was destroyed, Which can simulate the path of the flood inundation model was developed for the SIMOD (Simplified Inundation MODel). Multi Direction Method (MDM) for differential distributing the adjacent cells by using the slope and Flat-Water Assumption (FWA)-If more than one level higher in the cell adjacent to the cell level is the lowest altitude that increases the water level is equal to the adjacent cells- were applied For the evaluation of the model by setting the flooding scenarios were estimated hourly range from the target area. SIMOD model can significantly reduce simulation time because they use a simple input data of topography (DEM) and inflow flood. Since it is possible to predict results within minutes, if you can only identify inflow flood through the runoff model or levee collapse model. Therefore, it could be used to establish an evacuation plan due to flooding, such as EAP (Emergency Action Plan).

A Numerical Study on the Effects of Meteorological Conditions on Building Fires Using GIS and a CFD Model (GIS와 전산유체역학 모델을 이용한 기상 조건이 건물 화재에 미치는 영향 연구)

  • Mun, Da-Som;Kim, Min-Ji;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.395-408
    • /
    • 2021
  • In this study, we investigated the effects of wind speed and direction on building fires using GIS and a CFD model. We conducted numerical simulations for a fire event that occurred at an apartment in Ulsan on October 8, 2020. For realistic simulations, we used the profiles of wind speeds and directions and temperatures predicted by the local data assimilation and prediction system (LDAPS). First, using the realistic boundary conditions, we conducted two numerical simulations (a control run, CNTL, considered the building fire and the other assumed the same conditions as CNTL except for the building fire). Then, we conducted the additional four simulations with the same conditions as CNTL except for the inflow wind speeds and direction. When the ignition point was located on the windward of the building, strong updraft induced by the fire had a wide impact on the building roof and downwind region. The evacuation floor (15th floor) played a role to spread fire to the downwind wall of the building. The weaker the wind speed, the narrower fire spread around the ignition point, but the higher the flame above the building reaches. When the ignition point was located on the downwind wall of the building, the flame didn't spread to the upwind wall of the building. The results showed that wind speed and direction were important for the flow and temperature (or flame) distribution around a firing building.

Case Study of the Longest Roadway Tunnel in Korea, Baehuryeong Tunnel (국내 최장대 양방향 도로터널 설계사례-배후령터널)

  • Lee Seon-Bok;Je Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.432-440
    • /
    • 2005
  • Baehuryeong tunnel connects Chuncheon with Hwacheon in Kangwon, Korea, This tunnel is a single tunnel with 5,057 m long and two bidirectional lanes which will be extended into low lanes in the future. The estimated construction period of Baehuryeong tunnel is approximately 55 months. This tunnel will become the longest bidirectional roadway tunnel in Korea. Compared to a twin tunnel, a bidirectional single tunnel has two major disadvantages with regard to the ventilation system and ease of escape during fire. For these reasons, a service tunnel and the transverse ventilation system are planned first time in Korea. In case of fire, the tunnel ventilation design aims to maintain a smoke free layer for passenger evacuation. The geology of Baehuryeong tunnel site is mainly composed of gneiss and granite. Baehuryeong fault is a mainly large scale fault which stands vertical and parallels with tunnel direction. The influenced zone of this fault is within 70 m. Baehuryeong tunnel was designed that it was separated with the distance of more than 100 m from Baehuryeong fault for its safety.

Study for the Method to Secure the Safety of Fire-fighters in the Building Damaged by a Fire by Using Fire-resistant Design Theories - Mainly about Suggesting the Process and the Method for a Real-time Safety Evaluation by a Fire-fighter - (화재손상 건축 구조물에서 내화설계 이론을 활용한 소방관 안전확보 방안에 관한 연구 - 소방관에 의한 실시간 안전성평가 절차 및 방법의 제안을 중심으로 -)

  • Kwon, Yeongbae;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.86-95
    • /
    • 2016
  • Weight-bearing building materials are substantially weakened under high temperatures, and this is evident through the collapse of structures once engulfed by fire. Currently, there is no scientific or technological process of evaluating the real-time structural stability of a building whcih is engulfed by flame. There are many building design specifications which aim to reduce the risk of fire, but little consideration given to fire officer safety while operating in a dangerous building. This paper aims to provide direction within building policy in order to ensure the safe evacuation of fire-fighters in case of an impending building collapse. This paper suggests evaluation criteria for buildings which are damaged due to fire, autilizing current information on fire-resistant building design and a fire-resistant capacity.

A Study on the Fire Alarm System of Vertical Fire Spread Structure by Using FDS (FDS을 이용한 수직 연소확대 구조의 화재경보방식에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.100-107
    • /
    • 2016
  • Today, high-rise buildings expected to meet various needs and improve the quality of frequency of fire and the potential risks are increasing. In particular, the fire spread risk in the vertical direction is increasing. As a result there is a problem with delays in the evacuation time of occupants. To overcome this problem, there is a need to consider the structure of the building and develop a system for the early detection of fire by applying a fire alarm system according to the risk ranking. Therefore, this paper describes the vertical fire spread characteristics of a multistory double-skin and stairs structure with risk. The data were compared with that from the national and international fire alarms as well as with. smoke density, smoke detectors, visibility, and CO concentration using FDS. A fire alarm system for each structure is proposed.

Study on security measures for protecting major national facilities using the wind corridor (바람길을 활용한 국가중요지역 안전대책 강구에 관한 연구)

  • Choi, Kee-Nam
    • Convergence Security Journal
    • /
    • v.11 no.5
    • /
    • pp.109-120
    • /
    • 2011
  • How meteorological situations have affected human life for survival have been an important element of living or military strategy throughout history. In modern society, overcrowding of cities has brought about many problems. Moreover, high-rise buildings and land cover have been causing abnormal weather conditions. The wind corridor, especially in urban areas has been flowing differently from the dominant weather condition of the surroundings. Therefore, the wind corridor in urban areas can be a main component in protecting major national facilities in urban areas from damage. Especially the wind corridor is a main factor to derive harm from poisonous substances in air. This paper seeks to find out the wind corridor in urban areas and the efficiency of that. In addition to that, it studies how to use the direction to protect major national facilities and areas from damage. It is considered that this study will be useful to make defence project, not only for preventing CBR(chemical, biological, and radiological) terrorism and violent assembly, but also for evacuation of people in case of big accidents or natural disasters.

The Fukushima Nuclear Disaster and Nuclear Safety Systems in Korea (후쿠시마 원전사고와 한국의 원전안전정책)

  • Choi, Ye-Yong;Suzuki, Akira;Lee, Sang-Hong;Paek, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.226-233
    • /
    • 2011
  • Exactly 25 years after the Chernobyl nuclear disaster, 11th of March 2011 the Fukushima nuclear accident occurred in Japan and was ranked at level 7 same to the Chernobyl. A Korean and Japanese joint civil survey was conducted around Fukushima on April 13-17. The radiation survey data clearly shows a large hotspot area between 20 km and 50 km radius north and west direction from the accident reactors, with the highest radiation recorded being 55.64 ${\mu}Sv/hr$ in the air, 99.89 ${\mu}Sv/hr$ in the surface air, and 36.16 ${\mu}Sv/hr$ in a car, respectively. 3.65 ${\mu}Sv/hr$ in the air and 6.89 ${\mu}Sv/hr$ in the surface air were detected at the playground of an elementary school in Fukushima City. Spring came with full cherry blossoms in Fukushima, but it was silent spring of radiation contamination. Interviews with Fukushima nuclear refugees reveal serious problems about Japanese nuclear safety systems, such as there was no practical evacuation drill within 1-10 km and no plan at all for 10-30 km areas. Several reforms items for Korean nuclear safety system can be suggested: minimization of accident damage, clear separation of regulatory and safety bureaus with a new and independent administrating agency, community participation and agreement regarding the safety system and levels, which is the major concern of 80% Korean. To tackle threats of nuclear disaster in neighboring nations like China, a new position entitled 'Ambassador for nuclear safety diplomacy' is highly necessary. The nuclear safety of Korea should no longer be the monopoly of those nuclear engineers and limited technocrats criticized as a 'nuclear mafia'.

A Study on Indoor Positioning based on Pedestrian Dead Reckoning Using Inertial Measurement Unit (IMU 센서를 사용한 보행항법 기반 실내 위치 측위 연구)

  • Lee, Jeongpyo;Park, Kyung-Eun;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.521-534
    • /
    • 2021
  • Purpose: In this paper, we propose an indoor positioning scheme based on pedestrian dead reckoning using inertial measurement unit. By minimizing the effects of the orientation error of smart-phone, the more accurate estimation for the direction, the step count, and the stride can be achieved. Method: The effectiveness and the performance of the proposed scheme is evaluated by experiments, and it is compared with the conventional scheme in the same conditions. Result: The results showed that the positioning error of the proposed scheme was 0.76m, while that of the conventional scheme was 1.84m. Conclusion: Sine most people carry his/her own smart-phone, the proposed scheme can be helpful to recognize where he/she was and was heading when the fast evacuation is needed in indoors.

A Study on Dissemination of Earthquake Response Technology and Improvement of Practicality through User Demand Surveys (사용자 수요조사를 통한 지진 대응기술의 보급 및 실용성 제고 방안 연구)

  • Choi, SeonHwa
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.26 no.4
    • /
    • pp.33-46
    • /
    • 2021
  • In Korea 2016, the largest earthquake occurred in Gyeongju since the beginning of monitoring earthquakes. Consecutively the second-largest earthquake occurred in Pohang. At that time, immediately after the earthquake, citizens were not notified adequate information for evacuation. In consequence the response process was very confusing and citizens were not able to properly evacuate to shelter. For resolving these problems, it is needed of a service to inform quickly information which citizens want to know immediately after the earthquake. So, we have developed the customized information service model, the earthquake safety service which help citizens to escape safely using an earthquake shaking alert device. In this paper, we will introduce this model and present the future direction of R&D and strategic plans for technology dissemination and improvement of practicality through user demand survey.