• Title/Summary/Keyword: Evacuation Distance

Search Result 79, Processing Time 0.035 seconds

Elevator evacuation studies using a computer program (컴퓨터프로그램을 이용한 엘리베이터 피난 연구)

  • Cha, Jong Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5525-5533
    • /
    • 2012
  • Because of ultra-high buildings or deeper underground space, recent buildings have the potential that people who have lack of physical strength collapse before arriving at the emergency exits when catastrophes occur. In case of fire, the way to escape is that first, people take the stairs of the adjacent areas and then use the elevator to the remaining distance by road to escape notice or be safe. For this reason, the skyscrapers guidelines of Seoul for information on the elevator for evacuation has been established. Nevertheless, when designing buildings to install a elevator for evacuation separately is not effective, so passenger elevators installation according to the criteria are encouraged to use as evacuation elevators. However, this does not include detailed design guidelines so far. Therefore, this study was to investigate design method to use the passenger elevator for evacuation according to the domestic law and international installation criteria, and to calculated number of lifts and refuge to use the elevator using by the ELVAC+ and PathFinder evacuation program.

Effectiveness of critical velocity method for evacuation environment in a railroad tunnel at fire situation (철도터널 내 화재 시 대피환경 확보를 위한 임계속도 산정식의 유효성 평가)

  • Lee, Seung-Chul;Lee, Jae-Heon;Lee, Seung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The effectiveness of one dimensional critical velocity method for evacuation environment at 10MW fire size in a railroad tunnel have been investigated in this paper by three dimensional CFD method. It was performed to evaluate the evacuation environment in terms of temperature distribution, visible distance distribution and CO concentration at some tunnel inlet velocity, 1m/s, 2m/s (near critical velocity), and 3m/s. At all inlet velocity, passenger should give away downward the flow direction because the inlet velocity can not afford to sufficient evacuation environment for passengers. In case of 3m/s inlet velocity, however, the evacuation environment for passengers is better than the other cases. To provide more safe evacuation environment on fire situation, tunnel inlet velocity should be larger than critical velocity.

  • PDF

Pre-resilience Group Activities Against a Forthcoming Big Flood Disaster in Tokyo Below-Sea-Level Area

  • Ichiko, Taro;Kato, Takaarki;Ishikawa, Kinji
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.3-8
    • /
    • 2011
  • In April 2010, Japan Cabinet Office has published the first countermeasure report for severe flood disasters. This report showed various flood-disaster scenarios and factors that widened damages. One of important suggestions was to transmit precious information for long-distance evacuation. So far, local municipalities have made Flood Hazard Map to inform resident risk and evacuation. In this paper, cognition and effectiveness of a flood hazard map in the down ARAKAWA river Tokyo were measured by social questionnaire survey. In conclusion, there were 3 factors to effect validity of a flood hazard map. There were (1) commitment to their neighborhood organization, (2) experience of Kathleen typhoon in 1947 and (3) level of using targeted river. As results, a logical diagram about a flood hazard map perception was drawn and discussed from a view of community-based approach.

  • PDF

Effects of evacuation delay time and fire growth curve on quantitative risk for railway tunnel fire (철도터널 화재 시 피난개시시간지연 및 화재성장곡선이 정량적 위험도에 미치는 영향)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu;Lee, Hoo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.809-822
    • /
    • 2018
  • A quantitative risk assessment has been introduced to quantitatively evaluate fire risk as a means of performance based fire protection design in the design of railway tunnel disaster prevention facilities. However, there are insufficient studies to examine the effect of various risk factors on the risk. Therefore, in this study, the risk assessment was conducted on the model tunnel in order to examine the effects of the evacuation start time delay and the fire growth curve on the quantitative risk assessment. As a result of the analysis of the scenario, the fatalities occurred mainly when escapes in the same direction as the direction of the fire smoke movement. In addition, after the FED exceeded 0.3, the maximum fatalities occurred within 10 minutes. In the range of relatively low risk, distance between cross passages, evacuation delay time and fire growth curve were found to affect the risk, but they were found to have little effect on the condition that the risk reached the limit. Especially, in this study, it was evaluated that the evacuation delay time reduction, fire intensity and duration reduction effect were not observed when the distance between cross passages was more than 1500 m.

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

Selection of Transition Point through Calculation of Cumulative Toxic Load -Focused on Incheon Area- (누적독성부하 산정을 통한 주민소산 전환시점 선정에 관한 연구 -인천지역을 중심으로-)

  • Lee, Eun Ji;Han, Man Hyeong;Chon, Young Woo;Lee, Ik Mo;Hwang, Yong Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.15-24
    • /
    • 2020
  • With the development of the chemical industry, the chemical accident is increasing every year, thereby increasing the risk of accidents caused by chemicals. The Ministry of Environment provides the criteria for determining shelter-in-place or outdoor evacuation by material, duration of accident, and distance from the toxic substance leak. However, it is hard to say that the criteria for determining the transition point are not clear. Transition point mean the time that evacuation method is switched from shelter-in-place to outdoor evacuation. So, the purpose of this study was to calculate appropriate transition point by comparing the cumulative toxic load. Namdong-gu in Incheon Metropolitan City was finally selected as the target area, considering the current status of the population of Incheon Metropolitan City in 2016 and the statistical survey of chemicals in 2016. The target materials were HCl, HF, and NH3. Modeling was simulated by ALOHA and performed assuming that the entire amount would be leaked for 10 min. Residents' evacuation scenarios were assumed to be shelter-in-place, immediate outdoor evacuation, and outdoor evacuation at an appropriate time after shelter-in-place. Based on the above method, the appropriate transition point from residents located in A(800 m away), B(1,200 m away), C(1,400 m away) and D(2,200 m away) was identified. In HCl, appropriate transition point was after 15 min, after 16 min, after 17 min, after 20 min in order by A, B, C and D. In HF, appropriate transition point was before 1 min or after 16 min, before 4 min or after 19 min, before 5 min or after 20 min, before 14 min or after 26 min in order by A, B, C and D. In NH3, appropriate transition point at A was before 4 min or after 16. Others are not in chemical cloud. This study confirmed the transition point to minimize the cumulative toxic load can be obtained by quantitative method. Through this, it might be possible to select evacuation method quantitatively that cumulative toxic load are minimal. In addition, if the shelter-in-place is maintained without transition to outdoor evacuation, the cumulative toxic load will increase more than outdoor evacuation. Therefore, it was confirmed that actions to reduce the concentration of chemicals in the room were necessary, such as conducting ventilation after the chemical cloud passed through the site.

The Spatial Location Analysis of Disaster Evacuation Shelter for Considering Resistance of Road Slope and Difference of Walking Speed by Age - Case Study of Seoul, Korea (도로경사와 연령별 보행속도 차이를 고려한 자연재난 대피소의 입지분석 - 서울시 사례분석)

  • Lee, So Hee;Goo, Sin Hoi;Chun, Young Woo;Park, Young Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.69-77
    • /
    • 2015
  • In Korea, local governments have decided the location of shelters as part of their disaster planning. However, no quantitative standards, such as assuming different hazard and shelter types, shelters' capacity, are specified in that planning. To propose the direction of disaster evacuation policy, first of all, the current state of shelters' location and evacuation area is needed to be analyzed. In addition, considering topographical condition such as road slope and physical strength by age are important factors to measure optimal evacuation route. The purpose is to suggest a new methodology of estimating optimal evacuation route considering resistance of road slope and difference of walking speed by age. Moreover, as a case study of Seoul, Korea, using coverage analysis of GIS analysis tool, the accessible area (or vulnerable area) to the shelters is evaluated based on the spatial distribution of disaster evacuation shelters and their accommodation capacity, according to evacuation time within 7.5, 15 and 30 minutes. The main results are summarized as follows: 1) The average area of disaster evacuation shelter per person is calculated as 0.45 square meters. Considering that the minimum shelters' area per person is 1 square meters, only 45% of people in Seoul can be accommodated. 2) The ratio of inhabitants who live in accessible area within 7.5 minutes presents only 33% of all. Furthermore, the ratio of inhabitants by age group of 5~9 or over 65 years old shows significantly lower percentage in comparison with 15~49 years old people.

Recommended Evacuation Distance for Offsite Risk Assessment of Ammonia Release Scenarios (냉동, 냉장 시스템에서 NH3 누출 사고 시 장외영향평가를 위한 피해범위 및 대피거리 산정에 관한 연구)

  • Park, Sangwook;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.156-161
    • /
    • 2016
  • An accident of an ammonia tank pipeline at a storage plant resulted in one death and three injuries in 2014. Many accidents including toxic gas releases and explosions occur in the freezing and refrigerating systems using ammonia. Especially, the consequence can be substantial due to that the large amount of ammonia is usually being used in the refrigeration systems. In this study, offsite consequence analysis has been investigated when ammonia leaks outdoors from large storages. Both flammable and toxic effects are under consideration to calculate the affected area using simulation programs for consequence analysis. ERPG-2 concentration (150 ppm) has been selected to calculate the evacuation distance out of various release scenarios for their dispersions in day or night. For offsite residential, the impact area by flammability is much smaller than that by toxicity. The methodology consists of two steps as followings; 1. Calculation for discharge rates of accidental release scenarios. 2. Dispersion simulation using the discharge rate for different conditions. This proactive prediction for accidental releases of ammonia would help emergency teams act as quick as they can.

The Analysis on Pre-hospital Cases of Cardiac Arrest and Drug Intoxication during Local Emergency Activities - Based on Differences between Elderly Group and Non-Elderly Group - (일개지역 구급활동 중 병원 전 심정지 및 약물중독 환자 분석 - 노인대 비노인의 차이를 중심으로 -)

  • Lee, Jae-Min;Yun, Hyeong-Wan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.83-93
    • /
    • 2010
  • Purpose: The purpose of this study is to determine potential differences in pre-hospital cases of cardiac arrest and drug Intoxication between elderly group and non-elderly group on local emergency activity sites of rescue 119 team for those cases, so that it can provide useful reference materials for a system of corresponding emergency medical services. Methods: Patients with cardiac arrest and drug intoxication in the elderly and the non-elderly group were analyzed by analyzing the Ambulance Run Report for 3 years from January 2007 to December 2009. Results: According to analysis on potential differences between elderly and the non-elderly group, it was found that there was no significant difference between elderly cases (evacuated to hospital due to cardiac arrest and drug poisoning) and non-elderly cases in year of onset (p = .247), quarter of onset (p = .813), sex (p = .235), consciousness state (p = .126), place of onset (p = .215) and number of first aid services (applied to emergency cases) respectively, but there were significant differences between elderly cases and non-elderly cases in guardian availability (p = .042), time zone of onset (p = .050), distance from the site of onset (p = .278), type of onset (p = .000), number of first aid services depending on distance of evacuation (p = .008) and effectiveness of emergency care (p = .003) on statistical basis. Conclusion: It is important to establish a system of early emergency case reports for rational emergency case management with lower mortality; shorten distance from the site of onset at each time zone of onset in emergency cases; employ more emergency team members; facilitate firsthand / secondhand medical instructions for emergency teams in specialized emergency care depending on distance of evacuation for each kind of onset (elderly group vs. non-elderly group); and improve rate of resuscitated emergency cases by extending the scope of works for emergency medical technicians into wider applications, so that it will be possible to take timely and appropriate measures for emergency settings of ever-increasing aged population in near future.

  • PDF

Considerations of the Optimized Protective Action Distance to Meet the Korean Protective Action Guides Following Maximum Hypothesis Accidents of Major KAERI Nuclear Facilities

  • Goanyup Lee;Hyun Ki Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.52-57
    • /
    • 2023
  • Background: Korea Atomic Energy Research Institute (KAERI) operates several nuclear research facilities licensed by Nuclear Safety and Security Commission (NSSC). The emergency preparedness requirements, GSR Part 7, by International Atomic Energy Agency (IAEA) request protection strategy based on the hazard assessment that is not applied in Korea. Materials and Methods: In developing the protection strategy, it is important to consider an accident scenario and its consequence. KAERI has tried the hazard assessment based on a hypothesis accident scenario for the major nuclear facilities. During the assessment, the safety analysis report of the related facilities was reviewed, the simulation using MELCOR, MACCS2 code was implemented based on a considered accident scenario of each facility, and the international guidance was considered. Results and Discussion: The results of the optimized protective actions were 300 m evacuation and 800 m sheltering for the High-Flux Advanced Neutron Application Reactor (HANARO), the evacuation to radius 50 m, the sheltering 400 m for post-irradiation examination facility (PIEF), 100 m evacuation or sheltering for HANARO fuel fabrication plant (HFFP) facility. Conclusion: The results of the optimized protective actions and its distances for the KAERI facilities for the maximum postulated accidents were considered in establishing the emergency plan and procedures and implementing an emergency exercise for the KAERI facilities.