• Title/Summary/Keyword: Evacuation Capacity

Search Result 71, Processing Time 0.02 seconds

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

Hydraulic & Hydrologic Design Criteria for an Emergency Drainage of Reservoir (II) (댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(II))

  • Yi, Jaeeung;Son, Kwangik;Kang, Min Suk
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.159-167
    • /
    • 2015
  • Low-level outlets are necessary to empty reservoir storage in case of emergency such as abrupt storage level rise due to storm, dam body inspection as well as initial reservoir storage filling. However, the Korean standard for low-level outlet should be complemented. In this study, the HEC-ResSim model is utilized to simulate and calculate the capacity of the outlets and the days of release in order to evacuate reservoir storage safely. Three cases are analyzed according to its capacity. As a large dam with more than $1,000{\times}106m^3$ total capacity, Soyanggang Dam is selected and as a medium dam between $100{\times}106m^3$ and $1,000{\times}106m^3$ total capacity, Habcheon Dam is selected. Finally as a small dam with a total capacity less than $100{\times}106m^3$, Daegok Dam is selected. The size of low-level outlet and days of storage evacuation is estimated and the applicability of the analysis method is studied.

Mapping Inundation Areas by Flash Flood and Developing Rainfall Standards for Evacuation in Urban Settings (GIS를 이용한 도시지역 돌발홍수 침수예상지도 작성 및 대피강우기준 개발)

  • Shin, Sang-Young;Yeo, Chang-Geon;Baek, Chang-Hyun;Kim, Yoon-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.71-80
    • /
    • 2005
  • As local flash flood exceeding planned capacity occurs frequently, localized preparedness and response to flood inundation are increasingly important. Using XP-SWMM model and GIS techniques, this study analyzes inundation areas by local flash flood and develops rainfall standards for evacuation with the case of Sadang-Cheon area, a local stream and its nearby highly populated watershed in the southern part of metropolitan Seoul, Flood inundation areas overflowed from drainage systems are analyzed and mapped by amount of rainfall that is derived from reference levels of stream flow. Rainfall standards for evacuation are comprised of 'watch' (40mm/hr) in preparing for near-future inundation and 'evacuation' (65mm/hr) in responding to realized inundation. The methods suggested by this case study may be applied to other urban areas for sound flood prevention policy measures and thus risk minimization.

  • PDF

GIS Based Analysis for the Capacity of Emergency Evacuation Shelters in Cheonan - Focused on Class-2 Shelters in Old Downtown (GIS를 활용한 천안지역 대피시설의 현황 및 수용능력 분석 -구도심지역의 2등급 대피시설을 중심으로)

  • Lee, Heewon;Sung, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4572-4579
    • /
    • 2013
  • South Korea people and government pour growing interest on emergency evacuation shelters due to recent threatening of North Korea provocation. However, survey says the border area suffers lack of 278 shelters compared to population, needless to say the lack of class-2 shelter in case of provocation. Firstly, this study visualized the evacuation buffer area and summarized acceptable population for all class (1~4) shelters in Cheoan neighbor(dong). Specifically, for the class-2 shelter coverage in old downtown neighbor (Sungjung-dong, Jungang-dong, Munsung-dong), this study calculated evacuation excluded population and deficient shelter area through GIS buffer analysis. As a result, the old downtown needs $25,546m^2$ shelter area more that can accommodate 56%(30,657man) of the population.

Effectiveness of BIM-based Human Behavior Simulation on Architectural Design Education -Focused on Exploration and Evaluation of Barrier-Free and Fire Evacuation Performances- (BIM 기반의 인간행동 시뮬레이션이 건축설계교육에 미치는 효과에 관한 연구 -무장애와 안전 및 피난설계의 성능탐구와 평가를 중심으로-)

  • Hong, Seung-Wan;Park, Ji-Young
    • Journal of KIBIM
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 2020
  • While the importance of barrier-free and fire evacuation design is highlighted in architectural design education, systemic analysis, and examination on such performances are still challenging due to methodological lacks. The present study investigates the effectiveness of BIM-based human behavior simulation for architecture major students' analytical examinations to promote barrier-free and fire evacuation performances. To achieve such an aim, quasi-experiments were conducted, which compare 50 students' analysis and examination scores according to the use and non-use of the simulation, and the data were collected via participants' survey and interview. As a result, T-Test and MANOVA analyses indicate that, compared with its non-use counterpart, the use of human behavior simulation better facilitates the students' (1) examination of the physical properties and dimensions for the disabled's accessibility and evacuation, (2) understanding of the bodily capacity and handicap of the disabled, (3) examination on the spatial layouts and locations of exits, (4) understanding on evacuees' urgent behaviors, and (5) responsibility as an architect. Based on previous studies, the reasons of statistical results are interpreted as the explicit observation and analytical measures of multiple numbers of virtual-evacuees and direct-experience from body range of the disabled responding to the populated occupants as what they face in authentic reality.

Evacuation and Sheltering Assistance for Persons with Special Needs at Times of Disaster: Lessons Learned from Typhoon 23, Heavy Rainfall and Earthquake Disasters in the Year 2004

  • Tatsuki, Sshigeo
    • 한국방재학회:학술대회논문집
    • /
    • 2009.02b
    • /
    • pp.36-42
    • /
    • 2009
  • A series of heavy rainfall, typhoon and earthquake disasters caused a proportionately large number of deaths among the elderly in the year 2004 in Japan. In response to these tragedies, the national government set up committees to reduce damage within the disaster vulnerable population for the next three years. The discussions in the committee led to a new conceptualization that disaster vulnerability was caused by a lack of interaction between a person's special needs and the environment's capacity and resources to meet them. This person-in-environment model of hazard vulnerability was applied to those who resided in the Nankai-Tonankai tsunami hazard-prone area. 123 home care service users were interviewed in terms of their self-evacuation ability, degree of social isolation, and building weakness as well as tsunami exposure risks. Results were quantified and scores of person-in-environmentmodel hazard vulnerability were obtained. These scores were then used to visualize socially created vulnerability by means of weighted kernel density mapping of both persons with special needs (PSN's) and persons with special needs at times of disaster (PSND's).

  • PDF

A Investigation study on the evaluation of evacuation capacity for egress safety deign in Korea(III) (국내 PBD기반 피난안전설계를 위한 피난용량 산정에 관한 연구(III) - 수평적 군집피난속도식의 제안 -)

  • Seo, Dong-Goo;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.334-339
    • /
    • 2008
  • Recently the consideration for occupant's security has been raised as very important design element from the fire by building's large sized, higher storied, and its compounded. But the domestic laws regulated the predicative laws according to the technical standard which has no difference from the past domestic evacuation regulation. Therefore, regulation of escape code and developing technology for Korean conditions are needed to reduce victims during disaster by protecting occupant and guiding people to safe places.

  • PDF

A Study on the Escape capacity for Evacuation safety Design of PBD foothold in Korea(I) (국내 PBD기반 피난안전설계를 위한 피난용량 산정에 관한 연구(I) - 국내외 피난용량 산정방안의 비교 -)

  • Seo, Dong-Goo;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.340-347
    • /
    • 2008
  • Recently the consideration for occupant's security has been raised as very important design element from the fire by building's large sized, higher storied, and its compounded. But the domestic laws regulated the predicative laws according to the technical standard which has no difference from the past domestic evacuation regulation. Therefore, regulation of escape code and developing technology for Korean conditions are needed to reduce victims during disaster by protecting occupant and guiding people to safe places.

  • PDF

A Study on the Performance Variation Depending on Using Period of Ionization Smoke Detector (이온화식연기감지기의 사용기간 경과에 따른 성능변화 연구)

  • Kim, Shi-Kuk;Baek, Won-Don;Ok, Kyung-Jea;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.175-179
    • /
    • 2008
  • This paper studied on the performance variation depending on using period of ionization smoke detector. In korea, there were a lot of loss of lives and property because of fire. In many cases, an alarm equipment didn't operate though it was set up, so it causes the failure of early evacuation and fire suppression. Accordingly, an experiment on the change of ionization smoke detector in capacity performed with ionization smoke detector which is set up with fire objects.

  • PDF

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF