• 제목/요약/키워드: Evacuated tube solar collector

검색결과 39건 처리시간 0.106초

인공태양에 의한 이중 진공 유리관의 집열특성에 관한 연구 (A Study on the Collector Characteristics of Evacuated Double Glass Tube by Artificial Sun)

  • 남용한;신재호;모종근;정한식;정효민;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1542-1547
    • /
    • 2003
  • This paper represents the solar collector performance with type of an evacuate double glass, and a copper tube was installed in center of collector to get a solar thermal energy. The one module of solar collector and artificial sun were used in this experiment The distance between artificial sun and solar collector was fixed at 0.5m, and this experimental condition was focused on winter season. The experiments were carried out. three times for getting a accurate data and the heat amount of one module evacuate d solar collector was estimated at out. 48 kcal/hr.

  • PDF

태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구 (A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test)

  • 김미연;최병도;김형근;박진철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

진공 유리관 태양열 집열기에 열파이프의 적용을 위한 기초 연구 (A Study on Application of a Heat Pipe to an Evacuated Glass Tube Solar Collector)

  • 김철주
    • 태양에너지
    • /
    • 제12권2호
    • /
    • pp.9-17
    • /
    • 1992
  • This is an experimental work concerning about an application of a heat pipe to an evacuated-glass-tube solar collector system. A methanol heat pipe with length of 0.7 m and diameter of 8 mm was manufactured and tested to compare its performance with that of freon thermosyphon which was originally used in a solar collector system fabricated at Thermomax Co.. Then this methanol heat pipe was utilized to be one component, i.e. heat transfer element, of the present experimental model of a solar collector. This model was performed the operation test as its absorber plate was irradiated by infrared lamps. The following results were obtained. (1) The methanol heat pipe was showed a stable operation when the variation of axial heat transport was $0{\sim}40$ watts and that of inclination angle was $30{\sim}90^{\circ}$. (2) The heat transport capability of the heat pipe was proved to be higher than that of the thermosyphon, because the heat transport limitation of the latter was occured at about 30 watt. (3) The heat pipe in a solar collector was also showed good performance as it transmitted absorbed energy.

  • PDF

Modeling and validation of a parabolic solar collector with a heat pipe absorber

  • Ismail, Kamal A.R.;Zanardi, Mauricio A.;Lino, Fatima A.M.
    • Advances in Energy Research
    • /
    • 제4권4호
    • /
    • pp.299-323
    • /
    • 2016
  • Cylindrical parabolic solar concentrators of small concentration ratio are attractive options for working temperatures around $120^{\circ}C$. The heat gained can be utilized in many applications such as air conditioning, space heating, heating water and many others. These collectors can be easily manufactured and do not need to track the sun continuously. Using a heat pipe as a solar absorber makes the system more compact and easy to install. This study is devoted to modeling a system of cylindrical parabolic solar concentrators of small concentration ratio (around 5) fitted with a heat pipe absorber with a porous wick. The heat pipe is surrounded by evacuated glass tube to reduce thermal losses from the heat pipe. The liquid and vapor flow equations, energy equation, the internal and external boundary conditions were taken into consideration. The system of equations was solved and the numerical results were validated against available experimental and numerical results. The validated heat pipe model was inserted in an evacuated transparent glass tube as the absorber of the cylindrical parabolic collector. A calculation procedure was developed for the system, a computer program was developed and tested and numerical simulations were realized for the whole system. An experimental solar collector of small concentration, fitted with evacuated tube heat pipe absorber was constructed and instrumented. Experiments were realized with the concentrator axis along the E-W direction. Results of the instantaneous efficiency and heat gain were compared with numerical simulations realized under the same conditions and reasonably good agreement was found.

완전유리식 진공관형 집열기의 성능 개선에 대한 연구 (A Study on the Performance Improvement of All-Glass type Solar Vacuum Collectors)

  • 강상훈;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제22권1호
    • /
    • pp.43-53
    • /
    • 2002
  • This study has been carried out to study the thermal performance of an all-glass type solar collector tube when a heat transfer medium is used with a heat storage unit capable of preventing pressure build-up within the tube. The heat storage unit is devised such that it performs the dual function of relieving excessive pressure and storing solar thermal energy. Different types of heat storage medium are tested under heat-up phase of a collector tube. It is found that the proposed unit could be used quite effectively if one wishes to capitalize more aggressively in harnessing the solar energy.

두 종류 태양열 집열기를 이용하는 대규모 태양열 시스템의 동작특성 분석 (Analysis of Operating Characteristics of Large-scale Solar Thermal System Using Two Types of Collectors)

  • 이동원;허재혁;김민휘
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.67-75
    • /
    • 2017
  • We have investigated the operating characteristics of $1,600m^2$ large-scale solar thermal system installed in an eco-friendly energy town in Chungbuk Innovation City. The operation criteria of the collecting pump and storage pump were different from the existing standard, and it was confirmed that each pump works well according to the changed criteria. Based on the data of the representative day, the daily collecting heat (efficiency) and the production (storing) heat (efficiency) were estimated. It was confirmed that the daily collecting heat (efficiency) of the flat plate type was higher than that of the evacuated tube type, but the useful heat production was more in evacuated tube type collector.

운량에 따른 태양열 시스템의 성능 분석에 관한 연구 (Study on the Performance Analysis of Solar Heating System with Cloud Cover)

  • 김원석;표종현;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1215-1219
    • /
    • 2009
  • In this study, the performance of solar assisted hybrid heat pump system with cloud cover were analyzed by using experimental method in spring season. It was consisted of concentric evacuated tube solar collector, heat medium tank, heat storage tank, heat pump, and so on. As a result, the solar radiation should be maintained over $4.1\;MJ/m^2$ in order to operate solar heating system for heating. Solar heat of collector wasn't affected by ambient temperature, but cloud cover has a big effect to collector efficiency. In addition, the collector efficiency is about 50-60%, and solar fraction is 40% for this system.

  • PDF

태양열을 이용한 이중진공관형 집열기와 냉동기의 열성능에 관한 연구 (A study on the thermal performance of all glass evacuated tube collector and refrigerator using solar energy)

  • 윤준규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.324-331
    • /
    • 2013
  • 이중진공관형 집열기는 진공기술을 이용하여 흡수면에서 대류열손실을 줄일 수 있으며, 비교적 적은 온도차에서도 열수송능력과 열응답성이 빠른 이점이 있어 유용한 기기로 연구가 지속적으로 진행되고 있다. 본 연구에서는 태양열 집열기와 냉동기가 조합한 성능실험장치를 이용하여 태양열의 일사량, 유체온도의 제어조건에 따른 집열기의 동적 열성능을 파악하고, 이에 따른 항온조를 이용한 유체의 일정한 온도범위에서 냉동성능을 동시에 측정하여 열역학적 특성을 고찰하였다. 그 결과로서 집열효율의 관계식을 도출하였으며, 항온조의 출구온도 $18^{\circ}C$$22^{\circ}C$에서 집열기의 출구온도 $25^{\circ}C$로 설정하였을 때 항온조의 출구온도 $22^{\circ}C$ 경우가 외기온도 및 일사량이 증가함으로써 빠른 열전달특성을 보여 평균집열효율이 상승됨을 보였다. 또한 항온조의 출구온도 $18^{\circ}C$에서 냉동기의 성능계수는 6.2~7.1 정도의 결과를 얻게 되었다.

흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화 (Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray)

  • 김용;서태범;강용혁
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

진공관형 태양열 집열기의 구리-유리 직접 접합 기술 (Technique of Direct Copper to Glass Seal in an Evacuated Tube Solar Collector)

  • 김철영;임형봉;조남권;곽희열
    • 한국세라믹학회지
    • /
    • 제43권9호
    • /
    • pp.544-551
    • /
    • 2006
  • The sealing technique between a glass tube and a copper heat pipe in an evacuated tube solar collector is studied. In this study two different sealing techniques, such as flame method and furnace firing, are examined. After the sealing of a copper to a glass, the oxidation state of the copper and its bonding morphology were examined by SEM and XRD. Its oxidation was retarded by coating of borate solution on the copper, and $Cu_2O(cuprite)$ turned into CuO(tenorite) with increase in a firing temperature and firing time. Porous structure was found in the oxide layer when CuO formed. The best sealing morphology was observed when the thickness of the oxidation layer was less than $20{\mu}m$. The sealing technique performed in a furnace was promising and the satisfactory result was obtained when the sample was fired at $950^{\circ}C$ for 5 min under $N_2$ atmosphere. Annealing procedure is recommended to remove the stress left at the bonding zone.