• 제목/요약/키워드: Ethernet Communication

검색결과 351건 처리시간 0.111초

생체신호 측정 및 종합관리 시스템 (SiMACS) (Biological Signal Measurement, Archiving, and Communication System (SiMACS))

  • 우응제;박승훈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF

네트워크 기반 제어시스템의 통신부하 시험방법 (Traffic Test Method for Networked Control System)

  • 유광명;김종안;류호선
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.688-695
    • /
    • 2013
  • Networked Control Systems(NCS) contain the structure which controllers, actuators and sensors are connected to communication network. And they have been adopted in large and complicated plant area due to the advantages of mitigating computational bottleneck and maintenance. Although this structure provides many benefits, it brings in problems of unpredictable communication delay, data loss and corruption. This phenomena have to be considered in designing NCSs since it affects on overall control system stability. This paper introduces network traffic test method for ethernet based NCSs to find out maximum network usage which guarantee stable control operation. Test results shows this methods can be adopted in various types of NCSs and contributes economical system design and effective system operation.

산업설비를 위한 망관리 시스템의 설계 (Implementation of Network Management System for Industrial Device)

  • 강민수;곽동현;정을기;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.693-696
    • /
    • 2002
  • In this paper, network management system(NMS) was developed using Ethernet network for several devices. Recently, due to the development of the information communication, network has been constructed several place. And management system using network has been studied due to the increment of necessity of remote control for industrial device. Agent board that necessity of NMS, was developed using general micro-controller, it operates like stand-alone network device, supports TCP/IP protocol suite, has the ability to connect to industrial device and communicates each other. Also manager base on MMI was developed, it operates with agent board and supports effective management. To prove this system UPS(uninterruptible power supply) is selected as the example of industrial device. Finally, experimental result verifies the communication between agent board and manager.

  • PDF

배전계통 리클로우저 기반의 자율적 고장복구 방법론 (The Self-Fault Restoration Methodology based on the Recloser in the Distribution Systems)

  • 고윤석
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1681-1688
    • /
    • 2009
  • This paper proposes a new fault restoration method which adopts the recloser as top agent to release the problems of the data concentration and fault processing delay of the existing DAS(distribution Automation System) under the ubiquitous distribution system. In proposed method, top agent collects the data based on the multi-casting communication with the tie switches of the interconnection point, and then selects a closed switch(tie switch) to transfer the sound outage load to other feeders based on the heuristic search strategy step by step until the load transfer work is finished. Here, a new heuristic rule is developed which can guarantee the relational load balancing and line loss from the collected voltage data. Finally, the several faults are simulated for typical multi-section and multi-interconnection distribution system to prove the effectiveness of the proposed strategy, in particular, for each simulation cases, the load balancing index and line loss index of the obtained solution from the proposed method is compared with those of all of feasible solutions.

ATM-Metro 서비스 보안성 분석 (A Study on The Security of ATM-Metro Service)

  • 노선식;조정호;이동은
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.917-920
    • /
    • 2005
  • 본 논문에서는 광대역통합국가망에서 ATM-Metro 서비스의 망 구조 및 서비스 제공 방식을 분석한다. ATM-Metro 서비스를 제공함에 있어서 존재하는 보안 취약점 및 보안 공격을 분석하며, 이를 기반으로 안전하게 ATM-Metro 서비스를 제공하기 위한 일반적인 보안 강화 방안을 제시하고, ATM 접속 방식과 이더넷 접속 방식의 ATM 구간에서 보안 기능을 강호하기 위한 보안 모델을 제시한다. 또한 ATM-Metro Ethernet 구간에서 기본적인 보안 기능을 제공할 수 있는 VLAN 적용 방안을 제시하고, ATM-Metro서비스 전구간에서 보안성을 강화할 수 있는 방안을 제시한다.

  • PDF

u-Manufacturing 생산현장 정보취합 및 관리 방안 (Shop-Floor Information Management for u-Manufacturing)

  • 김동훈;송준엽;이승우;차석근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.942-945
    • /
    • 2005
  • This paper tried to analyze the collection and management method of shop-floor information for development of digital framework in u-manufacturing. In detail, the shop-floor information collection method through the direct communication with manufacturing devices using network Including RS-232C/422, field bus and ethernet is analyzed and proposed. In case the direct communication is impossible, the information collection method through additional sensors or data acquisition units is analyzed and proposed. Moreover, the collection method through bar code reader or touch screen of operators is analyzed and proposed to act up to machine to man/mobile/machine.

  • PDF

STM32 마이크로 컨트롤러에서 SOEM을 이용하는 EtherCAT 마스터 구현 (Implementation of an EtherCAT Master with SOEM on STM32 Microcontroller)

  • 강성진;서화일
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.11-16
    • /
    • 2023
  • EtherCAT is an Ethernet-based fieldbus system standardized in IEC 61158 and SEMI, and widely used in the fields of factory automation, semiconductor equipment and robotics. In this paper, without operating system, we have implemented an EtherCAT master with an open source EtherCAT master stack SOEM on STM32 Nucleo-144 board with an STM32F767 microcontroller. And its jitter performance has been evaluated at the output of the network port to include all the effects of the entire system in the results. The results show that the implemented EtherCAT master has precise control performance for control frequencies from 1KHz to 8KHz and relatively superior jitter performance compared to the EtherCAT masters with real-time patched Linux operating system.

  • PDF

실시간 EtherCAT 마스터의 네트워크 컨트롤러에 따른 성능 평가 (Performance Evaluation of a Real-time EtherCAT Master According to Network Controllers)

  • 서화일;강성진
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.19-22
    • /
    • 2024
  • EtherCAT is an Ethernet-based fieldbus system standardized in IEC 61158 and SEMI, and widely used in the fields of factory automation, semiconductor equipment and robotics. In this paper, we summarize the current status of Xenomai real-time framework and RTnet, which are essential for Linux operating systems to operate in real-time, and implement a real-time EtherCAT master system with these open sources. The real-time performance of the implemented EtherCAT master is evaluated according to Intel network controllers 82574L, I219, I210, and I225, respectively. The results show that the implemented EtherCAT master provides precise control performance for control frequencies from 1KHz to 8KHz and similar performance for I219, I210, and I225, and relatively slightly larger jitter for 82574L.

  • PDF

Wireless Ultrasonic Anemometer and Anemoscope Data-Logger System based on the Web

  • Yim, Jae-Hong;Kang, Young-Gwan;Lee, Woo-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.166-171
    • /
    • 2015
  • Recently, the international standard RS-422 serial communication, which was primarily designed for the communications between micro-controllers, has been used as a communication method on the ship. However, as the NMEA (National Marine Electronics Association) 2000 standardization progresses recently, a high-speed Ethernet-based communication environment is expected to be an alternative communication method instead of the RS-422 gradually. In addition, the ship's main instrumentation equipment with versatility and convenience is implemented to control devices as monitoring and controlling tools. This paper describes an implementation of wireless ultrasonic anemometer and anemoscope data processing and logger system using PC network, where the control processing equipment such as a separate operational console, data-logger, and indicator is required for the system. For these, the related element technologies to implement ultrasonic anemometer and anemoscope data processing system are expressed as a functional modules, and the NMEA 2000 standard certified data-logger system is implemented without the separate operational console.

환자 모니터링을 위한 인트라베드 및 인터베드 통신망 (Intrabed and Interbed Networks for Patient Monitoring)

  • 박승훈;우응제;김경수;최근호;김승태;이희철;서재준;김형진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.285-289
    • /
    • 1997
  • In this paper, we describe the intrabed and interbed network in a developed patient monitoring system. Intrabed network handles data communication among the main unit of a bedside monitor and parameter modules plugged in it. Interbed network deals with a higher level data communication among many bedside monitors, central stations, DB servers, and clinical workstations. Analyzing the data communication requirements in each stage of the system, we designed the intrabed network based upon RS-485 and HDLC protocol with 1Mbps data rate. Interbed network is designed to utilize the industry standard 10Base-T Ethernet with TCP/IP and UDP protocol. We present the specifications and the performances of the developed data communication networks in the patient monitoring system.

  • PDF