• 제목/요약/키워드: Etching test

검색결과 310건 처리시간 0.028초

접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도 (MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING)

  • 조영곤;고기종;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

레이저 처리가 상아질과 복합 레진의 결합에 미치는 영향 (Effects of laser-irradiated dentin on shear bond strength of composite resin)

  • 김성숙;박종일;이재인;김계순;조혜원
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.520-527
    • /
    • 2008
  • 목적: 이 연구는 산부식 대신 레이저로 표면처리를 하였을 때 복합레진과의 전단결합강도에 어떤 영향을 주는지 알아보기 위해 시행되었다. 재료 및 방법: 치아 우식증이 전혀 없는 건전한 최근에 발치된 대구치를 레진으로 매몰하고 상아질을 노출시킨 뒤 표면연마를 시행하 였다. 치아는 10개씩 4그룹으로 나누었다. 1) 아무 처리도 하지 않은 군, 2) 35% 인산으로 산부식한 군, 3) Er:YAG laser 레이저 처리된 군, 4) Er,Cr:YSGG laser로 처리된 군. 시편에 상아질 접착제 Single Bond2 (3M/ESPE)를 도포하고, 직경 3 mm, 높이 3 mm의 투명한 플라스틱관을 치아면 위에 두고 복합레진을 축성하였다. 모든 시편은 24시간동안 $37^{\circ}C$증류수에 보관 후 만능시험기를 이용하여 전단결합강도를 측정하였다. 결과: 레이저 처리시 각각 Er:YAG 레이저 처리는 $3.98{\pm}0.88$ MPa, Er,Cr:YSGG 레이저 처리는 $3.70{\pm}1.55$ MPa의 결합강도를 보였고, 통계적으로 유의한 차이를 나타내지 않았다. 아무 처리도 하지 않은 군의 결합강도는 $1.52{\pm}0.42$ MPa로 가장 낮은 결합강도를 나타내었고, 산처리를 한 군이 $7.10{\pm}1.86$ MPa로 가장 높은 전단결합강도를 보였으며, 이들은 레이저 처리한 군과 비교시 통계적으로 P < .001 유의수준에서 유의한 차이가 있는 것으로 나타났다. 결론: 치아와 레진의 전단결합강도 비교시 레이저 처리는 아무 처리도 않은 군에 비해서는 높지만 인산 etching보다 그 결합력이 떨어진다.

표면 처리재와 레진 시멘트가 IPS Empress 2의 전단결합강도에 미치는 영향 (Effect on Shear Strength of Ceramic Surface Treatment Materials and Three Resin Cements to IPS Empress 2)

  • 예선혜;이규복;이청희
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.157-170
    • /
    • 2002
  • IPS Empress 2의 산 부식 후 표면 처리재와 레진 시멘트 종류에 따른 전단 결합 강도를 비교 분석하기 위해서 실란 처리, 실리카 코팅 그리고 Targis link 처리군으로 분류하고 Panavia F, Variolink II와 Rely-X ARC 레진 시멘트 세종류를 이용해서 9개군에 각 군당 30개의 시편을 제작하였다. 그리고 구강환경에서의 변화를 알아보기 위해서 구강환경과 유사한 조건으로 $37^{\circ}C$ 증류수에서 24시간 수중침지, $37^{\circ}C$ 증류수에서 5주간 수중 침지, 그리고 5주간 수중침지 중 매주 2000회씩 10,000회의 열 순환을 한 다음 각 시편의 전단결합강도를 측정하고 파절면을 주사 전자현미경으로 관찰하여 다음과 같은 결론을 얻었다. 1. 표면처리에 따른 전단결합강도는 모든 군에서 유의한 차이를 보였다. 실란 처리, 실리카 코팅, 그리고 Targis link의 순으로 유의한 결합력의 감소를 보였다(p<0.001). 2. 레진 시멘트의 종류에 따른 차이를 비교한 결과에서 Targis link 도포한 군만 제외하고 나머지 군에서는 레진 시멘트의 종류에 따른 결합강도의 차이를 보였다(p<0.05). 3. 수중 침지 시간에 따른 전단 결합강도는 모든 군에서 유의한 차이를 보이지는 않았지만 실란을 처리 후 Panavia를 사용한 군, 실리카 코팅 처리 후 Variolink를 사용한 군, Targis link 처리 후 Rely-X ARC와 Variolink를 사용한 군에서는 결합력의 감소를 나타내었다(p<0.05). 4. 열 순환 시행시에는 실란과 실리카 코팅 처리후 Rely-X ARC를 사용한 군과 실리카 코팅 처리후 Panavia F를 사용한 군만 제외하고 나머지는 유의한 결합력의 감소를 보였다(p<0.05). 5. 파절 시험 후 시편에 대한 주사 전자 현미경 관찰결과 모든 군에서 복합성 파절 양상을 보였다.

Effect of microthreads on removal torque and bone-to-implant contact: an experimental study in miniature pigs

  • Kwon, Yee-Seo;Namgoong, Hee;Kim, Jung-Hoon;Cho, In Hee;Kim, Myung Duk;Eom, Tae Gwan;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제43권1호
    • /
    • pp.41-46
    • /
    • 2013
  • Purpose: The objective of this study was to evaluate the effect of microthreads on removal torque and bone-to-implant contact (BIC). Methods: Twelve miniature pigs for each experiment, a total of 24 animals, were used. In the removal torque analysis, each animal received 2 types of implants in each tibia, which were treated with sandblasting and acid etching but with or without microthreads at the marginal portion. The animals were sacrificed after 4, 8, or 12 weeks of healing. Each subgroup consisted of 4 animals, and the tibias were extracted and removal torque was measured. In the BIC analysis, each animal received 3 types of implants. Two types of implants were used for the removal torque test and another type of implant served as the control. The BIC experiment was conducted in the mandible of the animals. The $P_1-M_1$ teeth were extracted, and after a 4-month healing period, 3 each of the 2 types of implants were placed, with one type on each side of the mandible, for a total of 6 implants per animal. The animals were sacrificed after a 2-, 4-, or 8-week healing period. Each subgroup consisted of 4 animals. The mandibles were extracted, specimens were processed, and BIC was analyzed. Results: No significant difference in removal torque value or BIC was found between implants with and without microthreads. The removal torque value increased between 4 and 8 weeks of healing for both types of implants, but there was no significant difference between 8 and 12 weeks. The percentage of BIC increased between 2 and 4 weeks for all types of implants, but there was no significant difference between 4 and 8 weeks. Conclusions: The existence of microthreads was not a significant factor in mechanical and histological stability.

메조기공 Silicon/Carbon/CNF 음극소재 제조 및 전기화학적 특성 (Synthesis and Electrochemical Characteristics of Mesoporous Silicon/Carbon/CNF Composite Anode)

  • 박지용;정민지;이종대
    • 공업화학
    • /
    • 제26권5호
    • /
    • pp.543-548
    • /
    • 2015
  • 리튬이온 전지용 음극소재의 용량 및 사이클 성능을 향상시키기 위해서 Si/C/CNF 합성물의 특성이 조사되었다. 제조과정으로는 SBA-15를 합성하고 볼밀링을 이용한 마그네슘환원을 통해 Si/MgO를 얻은 다음, Phenolic resin과 CNF를 이용해 탄화과정을 거쳐 최종적으로 산처리하여 Si/C/CNF 활물질을 합성하였다. 합성된 Si/C/CNF는 BET, XRD, FE-SEM 그리고 TGA를 이용하여 분석하였다. $50^{\circ}C{\sim}70^{\circ}C$까지 온도에 따라 SBA-15를 합성한 결과 $60^{\circ}C$에서 가장 큰 비표면적을 갖는 결과를 얻었다. 또한 LiPF6 (EC : DMC : EMC = 1 : 1 : 1 vol%) 전해질을 사용하여, 충방전, 사이클, CV와 임피던스 등과 같은 전기화학적 테스트를 수행하여 Si/C/CNF 전극의 이차전지 음극활물질로서 성능을 조사하였다. Si/C/CNF (Si : CNF = 97 : 3 중량비)를 이용한 전지의 용량은 1,947 mAh/g으로 다른 합성물보다 우수한 결과를 보였다. CNF 첨가량이 3 wt%에서 11 wt%로 증가함에 따라 용량 보존율이 84~77%로 안정성이 감소되었다. Si/C/CNF 합성소재 전극이 이차전지의 사이클 성능과 전기전도도를 개선할 수 있다는 것을 알 수 있었다.

광중합형 복합레진 수리시 표면처리가 전단결합강도에 미치는 영향 (THE EFFECT OF SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH OF REPAIRED COMPOSITES)

  • 문장원;이광원;박수정
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.156-165
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of surface treatments on the shear bond strength between new and old composites. Circular cavities prepared on the center of acrylic resin mold and the prepared cavities were filled with composite resin. They randomly assigned into control group and 8 groups according to the difference in surface treatments of old composites; Control group: no surface treatment, Group 1: surface treated with #120 SiC paper & bonding agent, Group 2: surface treated with #400 SiC paper & bonding agent, Group 3: surface treated with #120 SiC paper, 32% $H_3PO_4$ & bonding agent, Group 4: surface treated with #400 SiC paper, 32% $H_3PO_4$ & bonding agent, Group 5: surface treated with #120 SiC paper, primer & bonding agent, Group 6: surface treated with #400 SiC paper, primer & bonding agent, Group 7: surface treated with #120 SiC paper, 32% $H_3PO_4$, primer & bonding agent, Group 8: surface treated with #400 SiC paper, 32% $H_3PO_4$, primer & bonding agent. New composites were applicated on the old composites of experimental groups. The shear bond strengths for the experimental specimen were measured and the results were analyzed by using one way ANOVA. The observations of surface morphology after SiC paper roughening and debonded surface morphology after shear bond strength test were done by SEM. The results were as follows; 1. Shear bond strengths for specimens roughened with #120 SiC paper matching with the particle size of coarse diamond bur were significantly higher than those for the specimens with #400 SiC paper(P<0.05). By SEM, the surface of the specimens roughened with #120 SiC paper was more irregular than the specimens with #400 SiC paper. 2. Shear bond strengths for specimens treated with 32% $H_3PO_4$ etchant, primer, bonding resin were significantly higher than those for specimens treated with 32% $H_3PO_4$ and bonding resin(P<0.05). 3. Shear bond strengths for the specimens treated with 32% $H_3PO_4$ etchant and bonding resin were significantly higher than those for specimens treated with only bonding resin(P<0.05). There was no remarkable change of surface morphology after 32% $H_3PO_4$ etching. 4. It was possible to observe mixed fracture patterns (the cohesive fracture of old composite and the adhesive fracture between old and new composite) in the specimens roughened with #120 SiC paper, but almost adhesive fracture in the specimens roughened with #400 SiC paper.

  • PDF

상아질 삭제기구가 자가부식 접착제의 결합강도에 미치는 효과 (EFFECT OF CUTTING INSTRUMENTS ON THE DENTIN BOND STRENGTH OF A SELF-ETCH ADHESIVE)

  • 이영곤;문소라;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제35권1호
    • /
    • pp.13-19
    • /
    • 2010
  • 이 연구는 다이몬드 포인트와 카바이드 버 및 SiC paper로 삭제한 상아질에 대한 자가부식 프라이머 접착제의 결합강도를 비교하고, 실험실에서 사용하는 SiC paper와 유사한 결합강도를 나타내는 회전용 삭제기구를 알아보기 위하여 시행하였다. 56개의 발거된 대구치 치관의 교합면 상아질을 노출시켜 1.2 mm의 두께의 시편을 제작한 후 8개의 군으로 분류하였다. 1군은 standard diamond point (TF-12), 2군은 fine diamond point (TF-12F). 3군은 extrafine diamond point (TF-12EF), 4군은 cross-cut carbide bur (no. 557), 5군은 plain-cut carbide bur (no. 245), 6군은 P 120-grade SiC paper, 7군은 P 220-grade SiC paper, 8군은 P 800-grade SiC paper를 사용하여 각 시편의 상아질 표면을 약 0.2 mm정도 삭제하였다. 상아질 표면에 Clearfil SE Primer와 Bond를 적용하고 Tygon tube를 이용하여 Clearfil AP-X를 충전하고 40초간 광조사 하였다. 제작된 시편은 만능시험기를 이용하여 를 미세전단 결합강도는 측정한 후, 각 군의 결합강도를 one-way ANOVA와 Tukey검정을 이용하여 분석하여 다음과 같은 결과를 얻었다. 자가부식 프라이머 접착제 사용 시 상아질에 대한 개선된 접착을 위해서는 초미세입자 다이아몬드 포인트의 사용이 추천되며, 실험실적인 연구에서 P 220-grade SiC paper의 사용은 미세입자 다이아몬드 포인트나 카바이드 버로 삭제한 상아질 면과 유사한 결합강도를 나타내었다.

Zirconia ceramic의 표면처리 방법이 레진시멘트의 결합강도에 미치는 영향 (EFFECT OF SURFACE TREATMENTS OF ZIRCONIA CERAMIC ON THE BOND STRENGTH OF RESIN CEMENTS)

  • 김창훈;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.386-396
    • /
    • 2004
  • Statement of problem: It is not clear how to make a stable bonding between zirconia ceramic and resin cement. And the study about surface treatment of zirconia ceramic or bonding resin cement are not enough. Purpose: To measure and compare the shear bond strength of some resin cements on zirconia ceramic after different surface treatments. Material and method: 48 ceramic discs were made of 3 ceramic materials, zirconia ceramics (Zi-Ceram), heat-pressed ceramics (IPS Empress 2) and slip cast alumina ceramics (In-Ceram). According to the surface treatments of ceramic specimens and resin cements, specimens were classified into 6 groups and each group was composed of 8 specimens. For the surface treatment of Zi-Ceram group (test group), sandblasting and diamond bur preparation were applied and Superbond C&B and Panavia F were bonded respectively. For IPS Empress 2 group (control group), Variolink II was bonded after sandblasting, acid etching, silanization and for In-Ceram ALUMINA group (control group), Panavia F was bonded after sandblasting. After storing specimens in distilled water for 24 hours, the shear bond strength was measured by the universal testing machine. Results and conclusion: 1. Zi-Ceram group with Superbond C&B cement showed higher bond strength than with Panavia F cement regardless to the surface treatments (p<0.05). 2. In Zi-Ceram group with Superbond C&B cement, sandblasting treatment group (12.1MPa) showed higher bond strength than diamond bur treatment group (7.7MPa) (p<0.05). In Zi-Ceram group with Panavia F cement, there were no significant differences in the bond strength according to the surface treatments (p>0.05). 3. Zi-Ceram group with sandblasting and Superbond C&B cement (12.1MPa) showed the highest bond strength. The bond strength of this group was not significantly different from In-Ceram ALUMINA group (10.4MPa) (p>0.05) and lower than IPS Empress 2 group (15.9MPa) (p<0.05).

산부식 후 타액오염이 교정용 접착제의 결합강도에 미치는 영향 (THE EFFECTS OF SALIVARY CONTAMINATION OF ACID-ETCHED ENAMEL ON BRACKET BOND STRENGTH)

  • 김현덕;김종성;김정기
    • 대한치과교정학회지
    • /
    • 제26권3호
    • /
    • pp.309-316
    • /
    • 1996
  • 본 연구는 산부식 법랑질의 타액오염 효과를 오염 시간별 전단결합강도를 통해 알아보고 주사 전자현미경으로 표면 변화를 관찰하고자 하였다. 타액오염 시간이 전단결합강도에 미치는 영향을 관찰하기 위하여 38% 인산용액으로 15초와 60초 산부식한 후 타액으로 0초, 1초, 20초, 60초동안 오염시켜 세척과 건조 후 주사 전자현미경으로 부식면을 검경하였으며, 교정용 레진을 이용하여 브라켓 접착 후 전단결합강도를 측정하고 통계 처리하여 다음과 같은 결과를 얻었다. 1. 타액에 오염시키지 않은 15초 산부식 군과 60초 산부식 군 사이의 전단결합강도는 통계적으로 유의한 차를 보이지 않았으나, 60초 산부식군에서 전단결합강도가 조금 낮았다. 2. 15초, 60초 산부식군에서 대조군, 1초, 20초, 60초의 타액오염 시간의 차이 에 따른 전단결합강도는 통계적으로 유의한 차를 보이지 않았으나, 타액오염시간의 증가에 따라 전단결합력이 낮아지는 경향을 보였다. 3. 주사 전자현미경 관찰시 대조군에서는 특징적인 부식양상을 보였으나 타액오염 군에서는 유기물이 침착되어 있었다.

  • PDF

Robust Design for Showerhead Thermal Deformation

  • 공대위;김호준;이승무;원제형
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF