• Title/Summary/Keyword: Etching test

Search Result 310, Processing Time 0.026 seconds

MICROLEAKAGE OF RESILON: EFFECTS OF SEVERAL SELF-ETCHING PRIMER (Resilon을 이용한 근관충전 시 수종의 치면처리제에 따른 미세누출 평가)

  • O, Jong-Hyeon;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.133-140
    • /
    • 2008
  • The purpose of this study was to compare the apical micro leakage in root canal filled with Resilon by several self-etching primers and methacrylate-based root canal sealer. Seventy single-rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with Gate-Glidden drills and .04 Taper Profile to ISO #40. The teeth were randomly divided into four experimental groups of 15 teeth each according to root canal filling material and self-etching primers and two control groups (positive and negative) of 5 teeth each as follows: group 1 - gutta percha and $AH26^{(R)}$ sealer: group 2 - Resilon, $RealSeal^{TM}$ primer and $RealSeal^{TM}$ sealer: group 3-Resilon, Clearfil SE $Bond^{(R)}$ primer and $RealSeal^{TM}$ sealer group 4-Resilon, $AdheSe^{(R)}$ primer and $RealSeal^{TM}$ sealer. Apical leakage was measured by a maximum length of linear dye penetration of roots sectioned longitudinally by diamond disk. Statistical analysis was performed using the One-way ANOVA followed by Scheffe's test. There were no statistical differences in the mean apical dye penetration among the groups 2, 3 and 4 of self-etching primers. And group 1, 2 and 3 had also no statistical difference in apical dye penetration. But, there was statistical difference between group 1 and 4 (p < 0.05). The group 1 showed the least dye penetration. According to the results of this study, Resilon with self-etching primer was not sealed root canal better than gutta precha with $AH26^{(R)}$ at sealing root canals. And there was no significant difference in apical leakage among the three self-etching primers.

Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment (법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교)

  • Lee, Ye-Rim;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.72-80
    • /
    • 2019
  • Purpose: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. Materials and Methods: G-FIX and LightFix were used as tooth splinting materials. Twenty bovine mandibular incisors were used for the preparation of the specimens. The exposed enamel surface was separated into four parts. Each tooth was treated with 37% phosphoric acid, 37% phosphoric acid + adhesive resin, 37% phosphoric acid + G-premio bond, and G-premio bond for each fraction. Shear bond strength was measured using a universal testing machine. After measuring the shear bond strength, the fractured surface of the specimen was magnified with a microscope to observe the fracture pattern. Two-way ANOVA was used to verify the interaction between the material and the surface treatment method. One-way ANOVA was used for comparison between the surface treatment methods of each material and post-hoc test was conducted with Scheffe's test. An independent t-test was conducted to compare shear bond strengths between materials in each surface treatment method. All statistics were conducted at 95% significance level. Results: G-FIX, a tooth splinting resin, showed similar shear bonding strength when additional adhesive resins were used when material was applied after only acid etching, and LightFix showed the highest shear bonding strength when additional adhesive resins were used after the acid etching. In addition, both G-FIX and LightFix showed the lowest shear bond strength when only self-etching adhesive was applied without additional acid etching. Verification of interactions observed interconnection between resins and surface treatment methods. Most of the mixed failure was observed in all counties. Conclusion: When using G-FIX and LightFix, which are tooth-splinting materials, it is considered that sufficient adhesion will be achieved even after applying only acid etching as instructed by the manufacturer.

Surface Modification of Steel Tire Cords via Plasma Etching and Plasma Polymer Coating : Part I. Adhesive properties (플라즈마 고분자 코팅에 의한 강철 타이어 코드의 표면 개질 : 제1부. 타이어 코드의 접착성)

  • Kang, H.M.;Chung, K.H.;Kaang, S.;Yoon, T.H.
    • Elastomers and Composites
    • /
    • v.35 no.1
    • /
    • pp.53-62
    • /
    • 2000
  • Zinc plated steel tire cords were treated with RF plasma polymerization coating of acetylene or butadiene in order to enhance adhesion to rubber compounds. Plasma polymerization was carried out as a function of plasma power, treatment tune and gas pressure. In order to maximize adhesion, argon plasma etching was performed, with carrier gas such as argon, nitrogen and oxygen, while the adhesion of tire cords was evaluated via TCAT. Best results were obtained from a combination treatment of argon etching (90 W. 10 min, 30 mTorr) and acetylene plasma polymerization coating (10 W, 30 sec, 30 mTorr) with argon carrier gas (25/5:acetylene/argon). These samples exhibited a pull out force of 285N which is comparable to that obtained from the brass plated tire cords (290N).

  • PDF

Microfabrication of Photosensitive Glass Using Metal Patterning and Blank Exposure (금속 패터닝과 Blank노광을 이용한 감광성 유리의 미세가공)

  • Jo, Jae-Seung;Kang, Hyung-Bum;Yoon, Hye-Jin;Kim, Hyo-Jin;Lim, Hyun-Woo;Cho, Si-Hyeong;Lim, Sil-Mook
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.3
    • /
    • pp.99-104
    • /
    • 2013
  • The simple and cost-effective microfabrication method of photosensitive glass (PSG) using metal patterning and blank exposure was proposed. Conventional photolithography for micromachining of PSG needs a costly quartz mask which has high transmittance as an optical property. However, in this study the process was improved through the combination of micro-patterned Ti thin film and blank UV exposure without quartz mask. The effect of UV exposure time as well as the DHF etching condition was investigated. UV exposure test was performed within the range from 3 min to 9 min. The color and etch result of PSG exposed for 5 min were the most clear and effective to etch more precisely, respectively. The etching results of PSG in diluted hydrofluoric acid (DHF) with a concentration of 5, 10, 15 vol% were compared. The effect on the side etch was insignificant while the etch rate was proportional as the concentration increased. 10 vol% DHF results not only high etch rate of 75 ${\mu}m/min$ also lower side etch value after PSG etching. This method facilitates the microfabrication of PSG with various patterns and high aspect ratio for applying to advanced applications.

Effect of zirconia surface treatment using nitric acid-hydrofluoric acid on the shear bond strengths of resin cements

  • Cho, Jin Hyung;Kim, Sun Jai;Shim, June Sung;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.77-84
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the surface roughness of zirconia when using Zircos E etching system (ZSAT), applying a nitric acid-hydrofluoric acid compound as a pretreatment agent, and also to compare the shear bonding strength according to different resin cements. MATERIALS AND METHODS. ZSAT, air abrasion, and tribochemical silicacoating were applied on prepared 120 zirconia specimens (10 mm in diameter, 7 mm in height) using CAD/CAM. Each 12 specimens with 4 different resin cements (Panavia F 2.0, Rely X Unicem, Superbond C&B, and Hot bond) were applied to test interfacial bond strength. The statistical analysis was performed using SAS 9.1 (SAS Institute Inc., Cary, NC, USA). The results are as follows: after application of the ZSAT on the zirconia specimens, surface roughness value after 2-hour etching was higher than those after 1- and 3-hour etching on SEM images. RESULTS. For Superbond C&B and Rely X Unicem, the specimens treated with ZSAT showed higher shear bond strength values than those treated with air abrasion and tribochemical silicacoating system. Regarding the failure mode of interface over cement and zirconia surface, Rely X Unicem and Hot bond showed cohesive failures and Panavia F 2.0 and Superbond C&B showed mixed failures. CONCLUSION. Zircos E etching system in zirconia restoration could increase its shear bond strength. However, its long term success rate and clinical application should be further evaluated.

The etch characteristic of TiN thin films by using inductively coupled plasma (유도결합 플라즈마를 이용한 TiN 박막의 식각 특성 연구)

  • Park, Jung-Soo;Kim, Dong-Pyo;Um, Doo-Seung;Woo, Jong-Chang;Heo, Kyung-Moo;Wi, Jae-Hyung;Kim, Chang-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.74-74
    • /
    • 2009
  • Titanium nitride has been used as hardmask for semiconductor process, capacitor of MIM type and diffusion barrier of DRAM, due to it's low resistivity, thermodynamic stability and diffusion coefficient. Characteristics of the TiN film are high intensity and chemical stability. The TiN film also has compatibility with high-k material. This study is an experimental test for better condition of TiN film etching process. The etch rate of TiN film was investigated about etching in $BCl_3/Ar/O_2$ plasma using the inductively coupled plasma (ICP) etching system. The base condition were 4 sccm $BCl_3$ /16 sccm Ar mixed gas and 500 W the RF power, -50 V the DC bias voltage, 10 mTorr the chamber pressure and $40\;^{\circ}C$ the substrate temperature. We added $O_2$ gas to give affect etch rate because $O_2$ reacts with photoresist easily. We had changed $O_2$ gas flow rate from 2 sccm to 8 sccm, the RF power from 500 W to 800 W, the DC bias voltage from -50 V to -200 V, the chamber pressure from 5 mTorr to 20 mTorr and the substrate temperature from $20\;^{\circ}C$ to $80\;^{\circ}C$.

  • PDF

Efficient Shadow-Test Algorithm for the Simulation of Dry Etching and Topographical Evolution (건식 식각 공정 시뮬레이션을 위한 효율적인 그림자 테스트 알고리즘과 토포그래피 진화에 대한 연구)

  • Kwon, Oh-Seop;Ban, Yong-Chan;Won, Tae-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.41-47
    • /
    • 1999
  • In this paper, we report 3D-simulations of a plasma etching process by employing cell-removal algorithm takes into account the mask shadow effect os well as spillover errors. The developed simulator haas an input interface to take not only an analytic form but a Monte Carlo distribution of the ions. The graphic user interface(GUI) was also built into the simulator for UNIX environment. To demonstrate the capability of 3D-SURFILER(SURface proFILER), we have simulated for a typical contact hole structure with 36,000($30{\times}40{\times}30$) cells, which takes about 20 minutes with 10 Mbytes memory on sun ultra sparc 1. as an exemplary case, we calculated the etch profile during the reactive ion etching(RIE) of a contact hole wherein the aspect ratio is 1.57. Furthermore, we also simulated the dependence of a damage parameter and the evolution of topography as a function of the chamber pressure and the incident ion flux.

  • PDF

AN EXPERIMENTAL STUDY OF THE EFFECT OF ION EXCHANGE ON STRENGTHENING OF DENTAL PORCELAIN (이온교환법에 의한 치과용도재의 강도증진 효과에 관한 실험적 연구)

  • Lee Young-Kook;Lee Sun-Hyung;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.75-86
    • /
    • 1991
  • Ion exchange strengthening is a chemical process whereby large alkali ions(such as potassium) are substituted for smaller ions(sodium) within the surfaces of glasses and ceramics, thereby reducing the thermal expansion coefficient of this surface region, and creating beneficial state of compressive stress within the near surface region. The purpose of this study was to determine the effects of ion exchange and etching treatments on the strength of some dental porcelains. Two feldspathic dental porcelains(Vitadur-N, G-Cera) were used in this study. A commercial ion exchange paste and etching gel containing 8% hydrofluoric acid were used for surface conditioning. Transverse strength was measured using a universal testing machine and the technique of EPMA(electron probe micro analysis) was used to access the potassium contents. The results were as follows: 1. Improvement in strength was only obtained by treating the surface placed in tension. 2. No changes in the dimensions of the treated specimens were detected when samples were measured with a micrometer. 3. There was significant increase in transverse strength of G-Cera IV group treated with etching and ion exchange, compared with G-Cera II group only treated with ion exchange. 4. From the results of EPMA test, increase in potassium contents was observed on the surface treated with ion exchange paste.

  • PDF

Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

  • Kim, Yun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.207-214
    • /
    • 2012
  • Objectives: This study evaluated the influence of chlorhexidine (CHX) on the microtensile bonds strength (${\mu}TBS$) of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods: Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG) and total-etch adhesive system, Adper Single Bond 2 (3M ESPE) after the following surface treatments: (1) Priming only (Contax), (2) CHX for 15 sec + rinsing + priming (Contax), (3) Etching with priming (Adper Single Bond 2), (4) Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2). Resin composite build-ups were made with LuxaCore (DMG) using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to ${\mu}TBS$ after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results: CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions: 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in ${\mu}TBS$ between total-etching system and self-etching system.

EFFECT OF THE APPLICATION TIME OF SELF-ETCHING PRIMERS ON THE BONDING OF ENAMEL (자가부식 프라이머의 적용시간이 법랑질 접착에 미치는 영향)

  • Jin, Cheol-Hee;Cho, Young-Gon;Kim, Soo-Mee;Lee, Myeong-Seon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.224-234
    • /
    • 2008
  • The purpose of this study was to compare the normal and two times of application time of six self-etching primers applied to enamel using microshear bond strength (uSBS) test and the finding of scanning electronic microscope (SEM). Crown of sixty human molars were bisected mesiodistally and buccal and lingual enamel of crowns were partially exposed and polished with 600 grit SiC papers. They were divided into one of two equal groups subdivided into one of six equal groups (n = 10) by self-etching primer adhesives. After the same manufacture's adhesive resin and composites were bonded on the enamel surface of each group, the bonded specimens were subjected to uSBS testing and also observed under SEM. In conclusion, generally two times of primer application time increased the enamel uSBS, especially with the statistical increase of bond strength in adhesives involving high-pH primers.

  • PDF