• Title/Summary/Keyword: Establishment of Environmental Quality Standards

Search Result 34, Processing Time 0.031 seconds

Indoor Air Quality in Various Type of Public Facilities at Honam Province (호남지역의 다중이용시설별 실내공기질 실태 조사)

  • Seo, Byeong-Ryang;Jeong, Man-Ho;Jeon, Jun-Min
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

A Temporal Trend of Dioxins Levels in Environmental Media

  • Park, Kyunghee;Daeil Kang;Junheon Youn;Lee, Choong;Sunghwan Jeon;Jingyun Na
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.148-148
    • /
    • 2003
  • This study is to investigate the environmental levels and trend of dioxins, which was the 3$\^$rd/ year of environmental monitoring research for endocrine disrupting chemicals since 1999. Total 282 samples were analyzed from 115 sites including 26 sites of airs, 43 sites of waters, 11 sites of sediments and 35 sites of soil, which were the same as those of investigated sites in 2000. Sampling period was from June 2001 to June 2002. Target chemicals were seventeen species of 2,3,7,8-chlorine-substituted PCDD and PCDF congeners and were analyzed by the standard methods, established by National Institute Environmental Research (NIER). The average concentration of dioxins in air decreased from 0.324 pg-TEQ/N㎥ in 2000 to 0.287 pg-TEQ/N㎥ in 2001, and those in water and soil were 0.073pg-TEQ/L and 1.703pg-TEQ/dry g, respectively, which was the less values detected in 2000. In sediment, however, the value was 0.086pg-TEQ/dry g, which was the increase from the value of the year 2000. The concentration range of dioxins in air for 26 sites in 17 regions detected were 0.013∼l.664pg-TEQ/N㎥, 4 sites from those were exceeded the Air Quality Standards of Dioxin in Japan (0.6 pg-TEQ/N㎥). The tolerable daily intake of dioxins was calculated at the highest level (1.664) in air, with referring the soil and food data from Japan, was calculated to be 2.85pg-TEQ/kg/day, which was below the level of 4 pg-TEQ/kg/day suggested in KFDA(Korea). While the average concentration of dioxins in 15 big cities was 0.190 pg-TEQ/N㎥, that in 8 medium/small cities constituting an industrial complex was 0.558 pg-TEQ/N㎥. In water, the concentration range detected were 0∼0.946pg-TEQ/L and the trend of the average concentrations shows an increase from those of 1999 but decreased from those of 2000, any sites however were not exceeded the Water Quality Standards of Dioxin in Japan (1 pg- TEQ/L). In soil. the detected range were 0∼43.333 pg-TEQ/dry g and the average concentration decreased, compared with the results of 2000. According to the monitoring results by land utilization, the detected range were 0∼43.333pg-TEQ/dry g in farmland, 0.017∼0.601 pg-TEQ/dry g in the industrial area, 0.005∼0.049pg-TEQ/dry g in the park and 0.008∼1.825 pg-TEQ/dry g in the rest. In sediment, the detected range increased from 0∼0.244 pg-TEQ/dry g to 0∼0.537 pg-TEQ/dry g, based on the results of 2000. For the proper control of dioxins, continuous monitoring needs to be performed and in addition, the dioxin inventory should be prepared for major sources through the dioxin emission survey. These results would provide sound and solid basis for proper decision making of dioxins management like establishment of environmental quality standards in Korea.

  • PDF

Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

Establishment of Korea-China joint quality standards and improvement the performance of Non-hardening Waterproofing Material (비경화 방수재의 한·중 공동품질기준 마련 및 성능개선 연구)

  • Choi, Su-Young;An, Hyun-Ho;Choi, Young Hyun;Park, Wan-Goo;Kim, Dong-Bum;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.224-225
    • /
    • 2019
  • The purpose of this study was to develop a technology to prevent leakage of construction structures for the Chinese market. The first key development factor is to establish a joint quality standard that corresponds to all performance criteria set out in Chinese Standard JC / T 2428-2017. The second key development factor is to develop a product capable of exhibiting performance in a low temperature environment of $-30^{\circ}C$ and coping with 15mm structure behavior.

  • PDF

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Use of Tributary Water Quality and Flowrate Monitoring Data for Effective Implementation of TMDL (수질오염총량관리제의 효율적인 시행을 위한 지류하천 수질.유량모니터링 자료의 활용)

  • Kim, Young-Il;Jeong, Woo-Hyeok;Kim, Hong-Su;Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.2
    • /
    • pp.119-125
    • /
    • 2012
  • The tributary water quality and flowrate monitoring result, which is fundamental data for the establishment of the water environmental policy, is used as very important data for the implementation of TMDL. This study introduced how to use the tributary water quality and flowrate monitoring data for the analysis of the watersheds, the satisfactory assessment of water quality standards in the watersheds, the selection of watersheds for the establishment of the implementation plan, and the selection of the tributary catchments for improving the water quality using a stream grouping method. According to the analytical results of tributary catchment using water quality and flowrate monitoring data of thirty-seven tributaries in the Geum-River watershed at Chungcheongnam-do, the value of flowrate in the tributaries, which is located in the middle-lower Geum-River watershed, was greater than the other areas and the concentration of the water pollutants regardless of water quality parameters in the tributaries at Nonsancheon catchment was relatively higher than the other areas. The problems, which have the determination of satisfaction of water quality standards and selection of target watersheds for establishment of the implementation plan regardless of the water quality of tributary in the watershed due to the water quality and flowrate monitoring results of the main river, were improved use of the results of tributary water quality and flowrate monitoring. Also, the tributary catchments for improving the water quality, according to stream grouping method based on the results of tributary water quality and flowrate monitoring, were selected. In the Geum-River watershed at Chungcheongnam-do, the tributary in the Nonsancheon, Byeongcheoncheon, Seokseongcheon, Jocheon catchments, which has a large flow and a high concentration of water pollutants, should be preferentially selected for improving the water quality of the tributary in accordance with the reduction of the source of pollution.

Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing (실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례)

  • Kim, Jaehoon;Shin, Jinsoo;Lee, Chulgu;Lee, Jungyoung;Lee, Youngsun;Yu, Soonju
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

Treatment of residues of excavated carcasses burials (가축매몰지 소멸시 잔존물 처리방안)

  • Kim, Geonha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.3
    • /
    • pp.269-277
    • /
    • 2018
  • Burials for the rapid disposal of carcasses have diverse and profound effects on the rural living condition, natural environment, and local economy throughout construction, management and final destruction of burials. In this study, possible residue excavated from standard burials, storage using FRP (Fiberglass Reinforced Plastic) tanks, and microbial-treated burials are characterized as carcasses, contaminated soil by leachate, and wasted plastic film. Treatment technologies for volume reduction of the residue including composting, rendering, and thermal hydrolysis were investigated. If the solid and liquid residues generated during volume reduction treatment are directly transferred to the environmental facilities, it may cause disorder due to high concentrations of organics, antibiotics, and lipid. Benefits and drawbacks of composting as a volume reduction techniques are extensively investigated. We also discussed that proper treatment of excavated soils and the reusing the treated soil as agricultural purpose. For the protection of public health and worker's hygiene, treatment criteria including produced residue qualities, and quality standards for the treated soil as agricultural use are required. In addition, Scientific manual for the proper treatment of residues is required. It is necessary to consider the establishment of a pretreatment facility to the occurrence of large-scale residue treatment.

Introduction of the Basin Sewerage Plan in Japan through Case Studies of the Lake Biwa Sewerage System (비와호 유역하수도 사례분석을 통한 일본 유역하수도계획의 소개)

  • Han, Mideok;Park, Bae Kyung;Park, Ji Hyoung;Kim, Yong Seok;Rhew, Doug Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.533-541
    • /
    • 2015
  • We investigate the Japan's Master Plan of Comprehensive Sewerage System (JMPS) and Lake Biwa basin sewerage and suggest future development direction of the Watershed Sewerage System Maintenance Plan in Korea enforced on February 2, 2013. The JMPS is designed for compliance with the environmental standard for water quality under the Environmental Policy Act. The effluent standards applied in the master plan of Lake Biwa's Sewerage Plan for the Lake Biwa is tougher than the national standards. Therefore the Lake Biwa Baisn Sewerage System was the first in Japan to adopt facilities that perform advanced treatment for nitrogen and phosphorus removal. BOD, SS, T-N and T-P concentrations of discharge water of sewage are 0.9, 0.6, 5.5, 0.06 mg/L, respectively. Especially removal efficiency for BOD is 99.5 percent. It is necessary to study the diversification of the evaluation criteria, cost minimization approach, subsidy system improvement, economic concept of discharge load adjustment system and establishment of basin sewerage concept for the development of the basin sewerage plan in Korea.

Establishment of Role Between Central and Local Government for Implementation of Total Maximum Daily Load (수질오염총량관리제 시행에 있어서 중앙정부와 지방자치단체 간 역할정립)

  • Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.378-383
    • /
    • 2011
  • The policy of total maximum daily load (TMDL) was adopted to manage water pollutants so as to keep the total amount of pollutants in the watersheds within established target water quality. While the TMDL was implemented in all four major river basins, various problems occurred. Even though the corrections for problems were conducted, the role between central and local government was not established exactly. This study was presented to suggest a role between central and local governments for effective implementation of TMDL. When the central government establishes the environmental criteria with water quality standards and pollutants in the main rivers, the local government should establish the level of target pollutants in the watershed. Also, the local government should be continuously implementing the water quality and flowrate monitoring of the tributaries to find out the degree of water quality improvement in the tributaries. Especially, the basic plan of TMDL for the whole watershed should be established by the river basin environmental office at the central government. The local government should be established the implementation plan of TMDL for the watershed where exceeds the established target water quality. The performance assessment of TMDL should be implemented every year to the water quality and flowrate monitoring of the tributaries for satisfaction assessment of target water quality in the watershed by the lower-lever government. The performance assessment report of TMDL included with an analysis of causes for the excess water quality in the watershed should be submitted to the river basin environmental office at the end of the TMDL planning period.