• Title/Summary/Keyword: Ess control

Search Result 210, Processing Time 0.027 seconds

Attempt and Retry Estimation for the Quality-Control of Electronic Switching System (전자교환기 품질관리를 위한 발생 호수와 재시도 호수 추정)

  • Cha, Kyoung-Cheon;Jun, Duk-Bin
    • IE interfaces
    • /
    • v.18 no.3
    • /
    • pp.327-332
    • /
    • 2005
  • The call-attempt behavior in a telecommunications service is influenced by the launch of new services and the choice of subscribers. On Feb 28, 2005, there was a disastrous shut-down of major local electronic switching systems (ESS) due to an abrupt increase of call-attempts. This incident turned out to be a strong proof that appropriate forecasting attempts are necessary not only for the capacity planning of network but also for the quality control of ESS. In this paper, forecasting models are first developed to estimate the daily ESS call-attempts and user retrial rates and then meaningful interpretations of results will follow. Finally future research topics will be presented.

A Study on the ESS Construction and Proper Operation Considering the Load Characteristics of the Distribution Logistics Facilities (유통물류시설 부하특성을 고려한 ESS 구축 및 적정 운영 방안에 관한 연구)

  • Heo, Donghyeok;Choi, Okhwan;Kwon, Dongmyeong
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.36-46
    • /
    • 2019
  • Through the application of ESS-based fusion products to the demonstration site of the urban distribution logistics facilities for designing the peak control and the substitution before the emergency generator operation by product application and the effective application method by the product application and the data analysis by overcoming the spatial limitation of ESS installation and distribution, And the expansion of distribution and logistics facilities.

Data Link Control of TDX-1 ESS (TDX-1전전자 교환기의 데이터 링크 제어)

  • 유정주;최고봉;김영시
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1987.04a
    • /
    • pp.93-97
    • /
    • 1987
  • In this paper the data link control procedures for the TDX-1 ESS had been designed and implemented in accordance with the CCITT recommandation X.25 LAPB After a general discussion on intermational standards of link montrol procedures the TDX-1 data link control procedures are described in detail.

  • PDF

Study on Establishing Investment Mathematical Models for Each Application ESS Optimal Capacity in Nationwide Perspective (국가적 관점에서 각 용도별 ESS 적정용량 산정을 위한 투자수리모델 수립에 관한 연구)

  • Kim, Jung-Hoon;Youn, Seok-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.979-986
    • /
    • 2016
  • At present, electric power industry around the world are being gradually changed to a new paradigm, such as electrical energy storage system, the wireless power transmission. Demand for ESS, the core technology of the new paradigm, has been growing worldwide. However, it is essential to estimate the optimal capacity of ESS facilities for frequency regulation because the benefit would be saturated in accordance with the investment moment and the increase of total invested capacity of ESS facilities. Hence, in this paper, the annual optimal mathematical investment model is proposed to estimate the optimal capacity and to establish investment plan of ESS facility for frequency regulation. The optimal mathematical investment model is newly established for each season, because the construction period is short and the operation effect for the load by seasons is different unlike previous the mathematical investment model. Additionally, the marginal operating cost is found by new mathematical operation model considering no-load cost and start-up cost as step functions improving the previous mathematical operation model. ESS optimal capacity is established by use value in use iterative methods. In this case, ESS facilities cost is used in terms of the value of the beginning of the year.

A Study on the Off-Grid Photovoltaic Generation System with Sequential Voltage System (순차전압시스템을 고려한 독립형 태양광 발전 시스템에 관한 연구)

  • Kim, Gu-Yong;Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.364-367
    • /
    • 2020
  • This paper presents the off-grid PV-ESS system of sequential voltage control method applied to OR logic gate. The conventional off-grid PV-ESS system with the low-voltage series connection has problems due to capacity expansion. To solve these problems, this paper proposes a noble PV-ESS system with high efficiency and low cost by applying sequential voltage control technique of the high-voltage series connection of analog circuit type. The input voltage of DC to AC inverter can be converted from the low-voltage by the combinations of series connection of the conventional cascaded 24V solar cell unit modules to the high-voltage of 384V in battery. The output voltage of the battery was 384V as the each input voltage of three phase DC to AC inverter, and the each output voltage of three phase 10kW DC to AC inverter is designed to be AC380V@60Hz as the line to line rms voltage value. To prove the validity of the theoretical analysis by PSIM simulation, the operating characteristics of sequential voltage control system with OR logic gate were confirmed through experiment results.

A Study on the Energy Saving System with the LabVIEW (LabVIEW를 이용한 에너지 절감시스템에 관한 연구)

  • Oh, Jin-Seok;Jo, Kwan-Jun;Kwak, Jun-Ho;Jin, Sun-Ho;Kim, Jong-Do;Lee, Hong-chan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.250-251
    • /
    • 2005
  • The ESS(Energy Saving System) is composed of economic control algorithm for main sea water cooling pump with inverter. The control system of ESS is designed with the Field-Point and LabVIEW. This paper presents the control process and results of control and monitor for ESS.

  • PDF

Calculation of Photovoltaic, ESS Optimal Capacity and Its Economic Effect Analysis by Considering University Building Power Consumption (대학건물의 전력소비패턴 분석을 통한 태양광, ESS 적정용량 산정 및 경제적 효과 분석)

  • Lee, Hye-Jin;Choi, Jeong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.5
    • /
    • pp.207-217
    • /
    • 2018
  • Recently, the importance of energy demand management, particularly peak load control, has been increasing due to the policy changes of the Second Energy Basic Plan. Even though the installation of distributed generation systems such as Photovoltaic and energy storage systems (ESS) are encouraged, high initial installation costs make it difficult to expand their supply. In this study, the power consumption of a university building was measured in real time and the measured power consumption data was used to calculate the optimal installation capacity of the Photovoltaic and ESS, respectively. In order to calculate the optimal capacity, it is necessary to analyze the operation methods of the Photovoltaic and ESS while considering the KEPCO electricity billing system, power consumption patterns of the building, installation costs of the Photovoltaic and ESS, estimated savings on electric charges, and life time. In this study, the power consumption of the university building with a daily power consumption of approximately 200kWh and a peak power of approximately 20kW was measured per minute. An economic analysis conducted using these measured data showed that the optimal capacity was approximately 30kW for Photovoltaic and approximately 7kWh for ESS.

Suggestion of Logic to Control Power Plant Equipped ESS in case of Full Open Turbine Control Valve (ESS를 이용한 발전소 터빈제어밸브 전개 운전 제어로직 제안)

  • In Young Chung;Jae-Heon Lee
    • Plant Journal
    • /
    • v.18 no.4
    • /
    • pp.66-72
    • /
    • 2023
  • In order to respond to the demand for flexible operation of thermal power generation, development of natural sliding pressure operation that minimizes throttle loss by opening the turbine control valve 100% and maximize power generation efficiency in conjunction with ESS in order to quickly respond to fluctuations in the system frequency is required. The logic development of natural sliding pressure operation with ESS was developed to modify the existing logic at the power plant's top-level control logic such as the unit master, the boiler master and the turbine master. Cooperative control algorithms that complement the advantages and disadvantages of ESS operation (quick response, limited capacity) and power plant operation (slow response, continuous operation) not only improve efficiency when applied to actual power plants, but also respond quickly and flexibly to load demands to ensure system stability.

  • PDF

ESS Optimal Charge-Discharge Schedule Generation Method Using Model Predictive Control Framework (모델예측제어 프레임워크를 이용한 ESS 최적 충방전스케줄 생성기법)

  • Sim, Jin-Yong;Lim, Jong-Mok;Jung, Sug-In;Kim, Jae-Hyun;Hong, Seung-Pyo;Shin, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.232-233
    • /
    • 2019
  • ESS(Energy Storage System)의 도입을 통해 첨두부하의 경감(Peak Shaving)과 일종의 차익거래(Arbitrage) 효과를 실현할 수 있다. 본 논문에서는 경제적 이득의 극대화를 지향하는 ESS 최적 충방전스케줄 생성기법을 제안한다. 제안 기법은 모델예측제어(MPC: Model Predictive Control) 프레임워크를 기반으로 하였고 매트랩 시뮬레이션을 통하여 그 타당성을 검증하였다.

  • PDF

A Study on The Performance Verification and Economic Evaluation of ESS for Frequency Regulation Application (주파수조정용 ESS의 성능검증 및 경제성평가 알고리즘에 관한 연구)

  • Lee, Ju-Gang;Choi, Sung-Sik;Kang, Min-Kwan;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.738-744
    • /
    • 2017
  • Recently, the installation of energy storage systems (ESSs) has increased in parallel with the extension of renewable energy resources. However, there has been no concrete analysis ofthe performance verification and economic evaluation of ESSs,which makes it difficult to perform aneffective installation and operation of an ESS. In particular, there are no international technical standards and guidelines on electric ESS for frequency regulation applications. Therefore, acomprehensive study on the power quality, impact on grid, extent of contribution, and cost benefit study of ESS are strongly being required. Under these backgrounds, this paper proposes a performance verification algorithm on ESS for frequency regulation application based on ananalysis of the AGC(Automatic Generation Control) performance verification method of PJM in USA. In addition,this paper proposes an economic evaluation algorithm on a 500 MW installation of ESS for frequency regulation applications using the account settlement of an expensive gas-fired generation plant and coal-fired power generation plant. From the simulation with real ESS operation data and 500 MW installation case, it wasconfirmed that the ESS showssuperior performance toany other conventional generators and provides anannual benefit of 500 MW ESS are between 345~429 billon won.