• Title/Summary/Keyword: Error level

Search Result 2,511, Processing Time 0.031 seconds

A Study on the Development of the Automatic Level Measurement System (자동 표고 측정 장치 개발에 관한 연구)

  • 김종안;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.756-760
    • /
    • 1997
  • In this research, the automatic level measurement system used in land leveling was developed. By using a laser transmitter and a receiver as measuring equipments, level was measured automatically. The driving part of this system was composed of stepping motor, timing belt and pulley. It drived the laser receiver to track laser beam generated form the laser transmitter. The level measuring experiments were performed about three level change shapes (step, random, sine). This system could measure step level change of which amplitude was 40mm in 0.5s, random level change within .+-. mm, maximum measurement error. In case of sine level change, experiment was executed with varying the spatial frequency of level change. As a result, this system was able to measure sine level change of which spatial frequency was 0.5m $^{-1}$ accurately.

  • PDF

A study on the safety management method based on the risk assessment of KORAIL's level-crossing accidents (선진 위험도 평가 기반의 건널목사고 안전관리 전략 연구)

  • Jung, Do-Won;Wang, Jong-Bae;Lhim, Jea-Eun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1732-1750
    • /
    • 2010
  • Operation of KORAIL's level crossing is in charge of KORAIL. As taking over existing level crossing to KORAIL, they do not conduct risk assessments, so we do not know about any possibilities of inner risk. And present operation of safety of the level crossing is just regular checking of reaction and functions of safety equipments physically, we need to react to the changes of what's going on around of level crossing and incestigation of traffic flow and surrounding conditions more spontaneously. So, we have to prepare the strategies against accidents of level crossing cost-effectively based on regular risk assessments for sustainable safety improvements and overcome operational problems of present level crossing's safety. Here, we're going to investigate the level of safety level and present risk factors of the level crossing using risk assessments for accidents/error of the equipments to show operational strategies of level crossing based on risk assessments.

  • PDF

Analysis of Seismic Response due to the Dynamic Coupling Between a Primary Structure and Secondary System (구조물과 부계통간의 연계방법에 따른 지진응답 분석)

  • Jung, Kwangsub;Kwag, Shinyoung;Choi, In-Kil;Eem, Seunghyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • Seismic responses due to the dynamic coupling between a primary structure and secondary system connected to a structure are analyzed in this study. The seismic responses are compared based on dynamic coupling criteria and according to the error level in the natural frequency, with the recent criteria being reliant on the error level in the spectral displacement response. The acceleration responses and relative displacement responses of a primary structure and a secondary system for a coupled model and two different decoupled models of two degrees-of-freedom system are calculated by means of the time integration method. Errors in seismic responses of the uncoupled models are reduced with the recent criteria. As the natural frequency of the secondary system increases, error in the natural frequency decreases, but seismic responses of uncoupled models can be underestimated compared to that of coupled model. Results in this paper can help determine dynamic coupling and predict uncoupled models' response conservatism.

A Study on the PES Estimation for Developing High-TPI HDD (HIGH-TPI HDD 구현을 위한 PES ESTIMATION에 관한 연구)

  • Koh, Jeong-Seok;Kang, Seong-Woo;Han, Yun-Sik;Kim, Young-Hoon;Hwang, Tae-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.122-127
    • /
    • 2002
  • A frequency-domain PES estimation and its prediction method are proposed for the tightly-coupled servo/mechanical design of high-TPI HDD system above 100 kTPI. The major two disturbance energies which are related with mechanical vibrations inside of HDD are used to predict the drive-level PES, while considering closed-loop servo dynamics. One is the torque disturbance which mainly comes from aerodynamic excitation of HSA system and the other is the displacement disturbance from disk-spindle dynamics. In order to obtain the accurate error transfer function of closed-loop servo control, the plant model is measured by accurate experiment. The measured PES is compared with predicted one in terms of frequency-domain PES spectrum and its standard variation value. It is proved that the proposed frequency-domain PES estimation/prediction method is capable of predicting drive-level PES of high-TPI hard disk drive.

  • PDF

Experiment on Multi-Dimensioned IMM Filter for Estimating the Launch Point of a High-Speed Vehicle (초고속 비행체의 발사원점 추정을 위한 다중 IMM 필터 실험)

  • Kim, Yoon-Yeong;Kim, Hyemi;Moon, Il-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • In order to estimate the launch point of a high-speed vehicle, predicting the various characteristics of the vehicle's movement, such as drag and thrust, must be preceded by the estimation. To predict the various parameters regarding the vehicle's characteristics, we build the IMM filter specialized in predicting the parameters of the post-launch phase based on flight dynamics. Then we estimate the launch point of the high-speed vehicle using Inverse Dynamics. In addition, we assume the arbitrary error level of the radar for accuracy of the prediction. We organize multiple-dimensioned IMM structures, and figure out the optimal value of parameters by comparing the various IMM structures. After deriving the optimal value of parameters, we verify the launch point estimation error under certain error level.

Understanding Geographic Variation in Sales Performance through Offline and Online Channels (지역 특수성에 따른 오프라인·온라인 채널 성과의 이해)

  • Kim, Jeeyeon;Choi, Jeonghye;Chung, Yerim
    • Knowledge Management Research
    • /
    • v.17 no.3
    • /
    • pp.45-64
    • /
    • 2016
  • As the digital retail environement becomes prevalent, consumers are given greater opportunities to make purchases across physical and digital boundaries. Prior research emphasizes that the attractiveness of the digital or online channel is relatively determined by spatial specifics of physical locations. The overall market trend combined with prior research suggests that understanding spatial specifics becomes a key to managing both offline and online sales performance together. In this study, we focus on geographic variation in sales performance through offline and online channels and aim to investigate the channel-level sales difference between central and subsidiary areas. To this end, we obtain sales data of skincare and makeup products from a leading cosmetic company. Next, we examine spatial autocorrelations in data and then employ the spatial error models to study the effects of spatial specifics. The empirical findings are as follows. First, there are significant differences in category-specific and channel-level sales between central and subsidiary areas. Second, Moran's I statistics demonstrate the spatial autocorrelations of each variable. Third, spatial error models outperform simple regression models with lower AIC values. Finally, spatial specifics play a greater role in understanding online sales in subsidiary areas whereas they exert greater influence on offline sales in central areas. We believe our study advances the related theory and knowledge of multi-channel retailing and also contributes practically to location-dependent multi-channel strategies and sales data analytics.

A Study on Worker's Perception of Patient Safety Culture in a hospital (일개 병원의 환자안전문화에 대한 인식)

  • Lee, Hae-Won;Cho, Hyun-Sun;Kim, Sun-Hwa
    • Quality Improvement in Health Care
    • /
    • v.17 no.1
    • /
    • pp.89-105
    • /
    • 2011
  • Background : The purpose of study in to grasp the level of perception of hospital workers on the patient safety culture, consider the difference in perception of patients safety culture according to medical service and finally find out a way to establish patient safety culture in hospital. Methods : As for the data, the analysis on frequency, t-test, ANOVA and tukey test were carried out by using SPSS 12.0. Result : The results of comparison among the positive response ratios on the patients culture of hospital workers showed that the subjects had perceived the teamwork within units most positively(74.1%), and perceived most negatively on the non-punitive response to error(16.2%)and the staffing(26.2%). 68.6% of subjects answered that the medical error were mostly of always reported. when daytime working hours are longer, perception of patient safety culture ranked low. In general, departments for direct medical service than departments for indirect medical service assessed patient safety culture high. Conclusion : Organizational learning and teamwork within units, communication openness, active support of hospital management for patient safety, and cooperation across the units would be crucial to promote the overall perceptions of patients safety of hospital workers and the level of patients safety in the units and to improve the quality of the event reporting system.

  • PDF

A low-Gain Error Amplifier for Common-Mode Feedback Circuit (Common Mode Feedback 회로를 위한 저 증폭도 에러증폭기)

  • 정근정;노정진
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.714-723
    • /
    • 2003
  • An effective technique to increase the signal swing and reduce noise is to use fully-differential -circuits. However, design of a common-mode feedback (CMFB) circuit that stabilizes the common-mode output level is essential. In this paper, a general description is given to fully-differential amplifiers with their CMFB loops, then a new error amplifier that is just composed of transistors and stabilizes the DC output level is proposed. We designed a simple and efficient bias circuit that allows the stability and maximum input swing. Simulation result shows the enhanced phase margin and increased differential-mode input swing with a proposed error amplifier.

Estimation of RTP Accuracy Based the International Reference Level (국제기준을 적응한 치료계획시스템 정확성 평가)

  • Oh, Young-Kee;Kim, Ki-Hwan;Jeong, Dong-Hyeok;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • In this study, we have estimated error of calculation results for 5-type RTP systems and investigated a toleration for error of the RTPs referenced from the evaluation items of AAPM Report-62. For this study, we have introduced the concept of 'normal dose rate(NDR)' and compared the results of experiment and calculation from RTPs at the same reference level. The results from all RTPs were satisfied at various field shapes and heterogeneous phantom materials except the surface irregularity.

  • PDF

A 3-cell CCI(Cell-to-Cell Interference) model and error correction algorithm for Multi-level cell NAND Flash Memories (다중셀 낸드 플래시 메모리의 3셀 CCI 모델과 이를 이용한 에러 정정 알고리듬)

  • Jung, Jin-Ho;Kim, Shi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.10
    • /
    • pp.25-32
    • /
    • 2011
  • We have analyzed adjacent cell dependency of threshold voltage shift caused by the cell to cell interference, and we proposed a 3-adjacent-cell model to model the pattern dependency of the threshold voltage shift. The proposed algorithm is verified by using MATLAB simulation and measurement results. In the experimental results, we found that accuracy of the proposed simple 3-adjacient-cell model is comparable to the widely used conventional 8-adjacient-cell model. The Bit Error Rate (BER) of LSB and of MSB is improved by 28.9% and 19.8%, respectively, by applying the proposed algorithm based on 3-adjacent-cell model to 20nm-class 2-bit MLC NAND flash memories.