• Title/Summary/Keyword: Error Source

Search Result 1,250, Processing Time 0.03 seconds

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Effects of Correlated Color Temperature of LED Light Sources and a Flourescent Light Source on Visual Performance (LED광원과 형광광원의 상관색온도가 시작업 성능에 미치는 영향)

  • Baik, Seung-Heon;Jeong, In-Young;Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.18-26
    • /
    • 2009
  • Recently, from an environmental conservative point of view, the need of high-efficiency lighting system, using LED(Light Emitting Diode) light sources have been increased. However, applied LED light sources without regard to its color and pattern provide visual discomfort to occupant. The objective of this study is not only to evaluate the performance of task work under different correlated color temperature condition, but also furnish the preliminary data as concerning its purpose and user of inner space. For the purpose of this study, two types of LED light sources and a fluorescent light source were selected. Thirty undergraduate students served as the participants. Two different task work sheets were conducted to evaluate the accuracy and duration of time. Results from subjective performance, task work of error modification showed that LED light sources were 2.5[%] higher in accuracy with 17.1[%] lower duration than a fluorescent light source. In the case of reading task work, It is presented 20.6[%] decrease with the LED light sources comparison with a fluorescent light source.

Design and Implementation of Modified Current Source Based Hybrid DC - DC Converters for Electric Vehicle Applications

  • Selvaganapathi, S.;Senthilkumar, A.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.57-68
    • /
    • 2016
  • In this study, we present the modern hybrid system based power generation for electric vehicle applications. We describe the hybrid structure of modified current source based DC - DC converters used to extract the maximum power from Photovoltaic (PV) and Fuel Cell system. Due to reduced dc-link capacitor requirement and higher reliability, the current source inverters (CSI) better compared to the voltage source based inverter. The novel control strategy includes Distributed Maximum Power Point Tracking (DMPPT) for photovoltaic (PV) and fuel cell power generation system. The proposed DC - DC converters have been analyzed in both buck and boost mode of operation under duty cycle 0.5>d, 0.5<d<1 and 0.5<d for capable electric vehicle applications. The proposed topology benefits include one common DC-AC inverter that interposes the generated power to supply the charge for the sharing of load in a system of hybrid supply with photovoltaic panels and fuel cell PEM. An improved control of Direct Torque and Flux Control (DTFC) based induction motor fed by current source converters for electric vehicle.In order to achieve better performance in terms of speed, power and miles per gallon for the expert, to accepting high regenerative braking current as well as persistent high dynamics driving performance is required. A simulation model for the hybrid power generation system based electric vehicle has been developed by using MATLAB/Simulink. The Direct Torque and Flux Control (DTFC) is planned using Xilinx ISE software tool in addition to a Modelsim 6.3 software tool that is used for simulation purposes. The FPGA based pulse generation is used to control the induction motor for electric vehicle applications. FPGA has been implemented, in order to verify the minimal error between the simulation results of MATLAB/Simulink and experimental results.

Studies on Joint Source/Channel Coding for MPEG-4 Scalable Video Transmission in Mobile Broadcast Receiving Environments (이동방송수신환경에서 MPEG-4 계층적 비디오 전송을 위한 결합 소스/채널 부호화에 관한 연구)

  • Lee Woon-Moon;Sohn Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.3 s.303
    • /
    • pp.31-40
    • /
    • 2005
  • In this paper, we develop an approach toward JSC(Joint Source-Channel Coding) method for MPEG-4 based FGS(Fine Granular Scalability) video coding and transmission in fixed and mobile receiving environment(Digital Audio Broadcasting, DAB). The source coder used MPEG-4 FGS video codec, the channel coder used RCPC(Rate Compatible Punctured Convolution) code and the modulation method used QPSK modulation. We have considered channel environment of AWGN and mobile receiving environment. This study determined optimum Trade-off point between source bit rate and channel coding rate in variable channel states. We compared FGS-JSC method and general single layer CBR(Constant Bit Rate) transmission. In this results, FGS-JSC was appeared better performance than CBR transmission.

An efficient space dividing method for the two-dimensional sound source localization (2차원 상의 음원위치 추정을 위한 효율적인 영역분할방법)

  • Kim, Hwan-Yong;Choi, Hong-Sub
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.358-367
    • /
    • 2016
  • SSL (Sound Source Localization) has been applied to several applications such as man-machine interface, video conference system, smart car and so on. But in the process of sound source localization, angle estimation error is occurred mainly due to the non-linear characteristics of the sine inverse function. So an approach was proposed to decrease the effect of this non-linear characteristics, which divides the microphone's covering space into narrow regions. In this paper, we proposed an optimal space dividing way according to the pattern of microphone array. In addition, sound source's 2-dimensional position is estimated in order to evaluate the performance of this dividing method. In the experiment, GCC-PHAT (Generalized Cross Correlation PHAse Transform) method that is known to be robust with noisy environments is adopted and triangular pattern of 3 microphones and rectangular pattern of 4 microphones are tested with 100 speech data respectively. The experimental results show that triangular pattern can't estimate the correct position due to the lower space area resolution, but performance of rectangular pattern is dramatically improved with correct estimation rate of 67 %.

Range estimation of underwater moving source using frequency-difference-of-arrival of multipath signals (다중 경로 신호의 도달 주파수 차를 이용한 수중 이동 음원의 거리 추정)

  • Park, Woong-Jin;Kim, Ki-Man;Son, Yoon-Jun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.154-159
    • /
    • 2019
  • When measuring the radiating noise of an underwater moving source, the range information between the acoustic source and the receiver is an important evaluation factor, and the measurement standards such as a receiver position, a moving source depth and a speed are set. Although there is a method of using the cross correlation as a method of finding the range of the underwater moving source, this method requires a time synchronization process. In this paper, we proposed the method to estimate the range by comparing the Doppler frequency difference of the theoretically calculated multipath signal with the Doppler frequency difference of the multipath signal estimated from the received signal. The proposed method does not require a separate time synchronization process. Simulations were performed to verify the performance, and the ranging error of the proposed method reduced by about 95 % than that of the conventional method.

A field determination method of D-T neutron source yields based on oxygen prompt gamma rays

  • Xiongjie Zhang;Bin Tang ;Geng Nian;Haitao Wang ;Lijiao Zhang ;Yan Zhang ;Rui Chen ;Zhifeng Liu ;Jinhui Qu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2572-2577
    • /
    • 2023
  • A field determination method for small D-T neutron source yield based on the oxygen prompt gamma rays was established. A neutron-gamma transport equation of the determination device was developed. Two yield field determination devices with a thickness of 20 mm and 50 mm were made. The count rates of the oxygen prompt gamma rays were calculated using three energy spectra processing approaches, which were the characteristic peak of 6.13 MeV, the overlapping peak of 6.92 MeV and 7.12 MeV, and the total energy area. The R-square of the calibration curve is better than 94% and the maximum error of the yield test is 5.21%, demonstrating that it is feasible to measure the yield of D-T neutron source by oxygen prompt gamma rays. Additionally, the results meet the requirements for field determination of the conventional D-T neutron source yield.

Covariance-based source localization performance improvement for underwater ultra-short baseline systems (공분산 기반 수중 ultra-short baseline 시스템의 위치 추정 성능 개선 기법)

  • Sangman Han;Minhyuk Cha;Haklim Ko;Hojun Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.89-94
    • /
    • 2024
  • Since Ultra-Short BaseLine (USBL) uses an array with narrow sensor spacing, precise synchronization is required to improve source localization performances. However, in the underwater environment, synchronization errors occur due to relatively strong noise and underwater acoustic channels such as multipath and Doppler, which deteriorates the source localization performances. This paper proposes a covariance-based synchronization compensation method to improve the source localization performances of the underwater USBL systems. The proposed method arranges the received signals through cross-correlation and calculates the covariance of the arranged signals. The synchronization error is related to the phase difference in the covariance. Thus, the phase difference is estimated as the covariance and compensated. Computer simulations demonstrate that the proposed method has better source localization performances than the conventional cross-correlation method.

A Study on Estimating Earthquake Magnitudes Based on the Observed S-Wave Seismograms at the Near-Source Region (근거리 지진관측자료의 S파를 이용한 지진규모 평가 연구)

  • Yun, Kwan-Hee;Choi, Shin-Kyu;Lee, Kang-Ryel
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.121-128
    • /
    • 2024
  • There are growing concerns that the recently implemented Earthquake Early Warning service is overestimating the rapidly provided earthquake magnitudes (M). As a result, the predicted damages unnecessarily activate earthquake protection systems for critical facilities and lifeline infrastructures that are far away. This study is conducted to improve the estimation accuracy of M by incorporating the observed S-wave seismograms in the near source region after removing the site effects of the seismograms in real time by filtering in the time domain. The ensemble of horizontal S-wave spectra from at least five seismograms without site effects is calculated and normalized to a hypocentric target distance (21.54 km) by using the distance attenuation model of Q(f)=348f0.52 and a cross-over distance of 50 km. The natural logarithmic mean of the S-wave ensemble spectra is then fitted to Brune's source spectrum to obtain the best estimates for M and stress drop (SD) with the fitting weight of 1/standard deviation. The proposed methodology was tested on the 18 recent inland earthquakes in South Korea, and the condition of at least five records for the near-source region is sufficiently fulfilled at an epicentral distance of 30 km. The natural logarithmic standard deviation of the observed S-wave spectra of the ensemble was calculated to be 0.53 using records near the source for 1~10 Hz, compared to 0.42 using whole records. The result shows that the root-mean-square error of M and ln(SD) is approximately 0.17 and 0.6, respectively. This accuracy can provide a confidence interval of 0.4~2.3 of Peak Ground Acceleration values in the distant range.

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF