• Title/Summary/Keyword: Error Counter

Search Result 124, Processing Time 0.027 seconds

Time Synchronization Error and Calibration in Integrated GPS/INS Systems

  • Ding, Weidong;Wang, Jinling;Li, Yong;Mumford, Peter;Rizos, Chris
    • ETRI Journal
    • /
    • v.30 no.1
    • /
    • pp.59-67
    • /
    • 2008
  • The necessity for the precise time synchronization of measurement data from multiple sensors is widely recognized in the field of global positioning system/inertial navigation system (GPS/INS) integration. Having precise time synchronization is critical for achieving high data fusion performance. The limitations and advantages of various time synchronization scenarios and existing solutions are investigated in this paper. A criterion for evaluating synchronization accuracy requirements is derived on the basis of a comparison of the Kalman filter innovation series and the platform dynamics. An innovative time synchronization solution using a counter and two latching registers is proposed. The proposed solution has been implemented with off-the-shelf components and tested. The resolution and accuracy analysis shows that the proposed solution can achieve a time synchronization accuracy of 0.1 ms if INS can provide a hard-wired timing signal. A synchronization accuracy of 2 ms was achieved when the test system was used to synchronize a low-grade micro-electromechanical inertial measurement unit (IMU), which has only an RS-232 data output interface.

  • PDF

Navigation based Motion Counting Algorithm for a Wearable Smart Device (항법 기반 웨어러블 스마트 디바이스 동작 카운트 알고리즘)

  • Park, So Young;Lee, Min Su;Song, Jin Woo;Park, Chan Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.547-552
    • /
    • 2015
  • In this paper, an ARS-EKF based motion counting algorithm for repetitive exercises such as calisthenics is proposed using a smartwatch. Raw sensor signals from accelerometers and gyroscopes are widely used for conventional smartwatch counting algorithms based on pattern recognition. However, generated features from raw data are not intuitive to reflect the movement of motions. The proposed motion counter algorithm is composed of navigation based feature generation and counting with error correction. The candidate features for each activity are velocity and attitude calculated through an ARS-EKF algorithm. In order to select those features which reveal the characteristics of each motion, an exercise frame from the initial sensor frame is introduced. Counting processes are basically based on the zero crossing method, and misdetected counts are eliminated via simple classification algorithms considering the frequency of the counted motions. Experimental results show that the proposed algorithm efficiently and accurately counts the number of exercises.

Static Corrective Controllers for Implementing Fault Tolerance in Asynchronous Sequential Circuits (정적 교정 제어기를 이용한 비동기 순차 회로의 내고장성 구현)

  • Yang, Jung-Min;Kwak, Seong Woo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2016
  • Corrective controllers enable fault diagnosis and tolerance for various faults in asynchronous sequential circuits without resort to redesign. In this paper, we propose a static corrective controller in order to decrease the size of the controller. Compared with dynamic controllers, static controllers can be made using only combinational circuits, as they need no inner states. We address the existence condition and design procedures for static corrective controllers that overcome state transition faults. To show the validity and advantage, the proposed controller is applied to an SEU error counter implemented on FPGA.

Mechanical Design of Ring Laser Gyroscope Using Finite Element Method (링 레이저 자이로스콥을 위한 유한요소법 기계 설계)

  • Lee, Jeong Ick
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.107-111
    • /
    • 2013
  • The gyroscopes have been used as a suitable inertial instrument for the navigation guidance and attitude controls. The accuracy as very sensitive sensor is limited by the lock-in region (dead band) due to the frequency coupling between two counter-propagating waves at low rotation rates. This frequency coupling gives no phase difference, and an angular increment is not detected. This problem can be overcome by mechanically dithering the gyroscope. This paper presents the design method of mechanical dither by the theoretical considerations and the verification of the theoretical equations through FEM applications. As a result, comparing to the past result, the maximum prediction error of resonant frequency was within 3 percent and peak dither rate was within 5 percent. It was found that the theoretical equations can be feasible for the mechanical performance of dither.

A Design of Effective Analog-to-Digital Converter Using RC Circuit for Configuration of I2C Slave Chip Address (I2C 슬래이브 칩의 주소 설정을 위한 RC회로를 이용한 효과적인 아날로그-디지털 변환기 설계)

  • Lee, Mu-Jin;Seong, Kwang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.87-93
    • /
    • 2012
  • In this paper, we propose an analog-to-digital converter to set the address of a I2C slave chip. The proposed scheme converts a fixed voltage between 0 and VDD to the digital value which can be used as the address of the slave chip. The rising time and the falling time are measured with digital counter in a serially connected RC circuit, while the circuit is being charged and discharged with the voltage to be measured. The ratio of the two measured values is used to get the corresponding digital value. This scheme gives a strong point which is to be implementable all the parts except comparator using digital logic. Although the method utilizes RC circuit, it has no relation with the RC value if the quantization error is disregarded. Experimental result shows that the proposed scheme gives 32-level resolution thus it can be used to configure the address of the I2C slave chip.

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

The Mechanical Dither Design of Navigation Guide Structure (네비게이션 가이드 구조물의 기계적 진동설계)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.1949-1954
    • /
    • 2010
  • The gyroscopes have been used as a suitable inertial instrument for the navigation guidance and attitude controls. The accuracy as very sensitive sensor is limited by the lock-in region(dead band) due to the frequency coupling between two counter-propagating waves at low rotation rates. This frequency coupling gives no phase difference, and an angular increment is not detected. This problem can be overcome by mechanically dithering the gyroscope. This paper presents the design method of mechanical dither by the theoretical considerations and the verification of the theoretical equations through FEM(Finite Element Method) applications. As a result, the maximum prediction error of resonant frequency and peak dither rate was under 5 percent. The theoretical equations for the mechanical performances of dither can be said to be feasible.

A Switched-Capacitor Interface Based on Dual-Slope Integration (이중-적분을 이용한 용량형 센서용 스위치드-캐패시터 인터페이스)

  • 정원섭;차형우;류승용
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1666-1671
    • /
    • 1989
  • A novel switched-capacitor circuit for interfacing capacitive microtransducers with a digital system is developed based on the dual-slope integration. It consists of a differential integrator and a comparator. Driven by the teo phase clock, the circuit first senses the capacitance difference between the transducer and the reference capacitor in the form of charge, and accumulates it into the feedback capabitor of the integrator for a fixed period of time. The resulant accumulated charge is next extracted by the known reference charge until the integrator output voltage refurns to zero. The length of time required for the integrator output to return to zero, as measured by the number of clock cycle gated into a counter is proportional to the capacitance difference, averaged over the integration period. The whole operation is insensitive to the reference voltage and the capacitor values involved in the circuit, Thus the proposed circuit permits an accurate differental capacitance measurement. An error analysis has showh that the resolution as high as 8 bits can be expected by realizing the circuit in a monolithic MOS IC form. Besides the accuracy, it features the small device count integrable onto a small chip area. The circuit is thus particularly suitadble for the on-chip interface.

  • PDF

Measuring of Circular Motion Accuracy of NC Lathe using Linear Scales (리니어스케일을 이용한 NC 선반의 원 운동정도 측정)

  • 김영석;김재열;한지희;정정표;윤원주;송인석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1144-1149
    • /
    • 2003
  • It is very important to measure circular motion accuracy of NC lathes it affects accuracy, performance, interchange ability and quality of machine parts machined by the NC lathes in industries. So, in this study, measuring units system to measure circular motion accuracy two axes circular motion accuracy of NC lathes was composed of two optical linear scales installed on the z and x-axes of work coordinate system on NC lathe and a computer inserted with PC counter card enables to obtain measuring data. Here, ATC(Automatic Tool Changer) and moving part of linear scales are fixed with magnet bases in order to measure circular motion accuracy of the ATC of NC lathe. And next, computer software was developed in order to measure the circular motion accuracy of NC lathe under resolution of 0.1 $\mu\textrm{m}$ using two linear scales, and also computer softwares were developed so that measuring data could be modeled on plots and be analyzed numerically,

  • PDF

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.