• 제목/요약/키워드: Ergonomic User Interface Design

검색결과 15건 처리시간 0.02초

적응형 유전알고리즘을 이용한 사용자 인터페이스 설계 방법 개발 (Development of an User Interface Design Method using Adaptive Genetic Algorithm)

  • 정기효
    • 대한산업공학회지
    • /
    • 제38권3호
    • /
    • pp.173-181
    • /
    • 2012
  • The size and layout of user interface components need to be optimally designed in terms of reachability, visibility, clearance, and compatibility in order for efficient and effective use of products. The present study develops an ergonomic design method which optimizes the size and layout of user interface components using adaptive genetic algorithm. The developed design method determines a near-optimal design which maximizes the aggregated score of 4 ergonomic design criteria (reachability, visibility, clearance, and compatibility). The adaptive genetic algorithm used in the present study finds a near-optimum by automatically adjusting the key parameter (probability of mutation) of traditional genetic algorithm according to the characteristic of current solutions. Since the adaptive mechanism partially helps to overcome the local optimality problem, the probability of finding the near-optimum has been substantially improved. To evaluate the effectiveness of the developed design method, the present study applied it to the user interface design for a portable wireless communication radio.

차세대 첨단 도시철도시스템의 인간공학적인 형상디자인 설계 방법에 관한 연구 (A study for the ergonomics shape-design method of advanced urban transit system)

  • 박성혁;여민우;김길동;오세찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.928-934
    • /
    • 2005
  • In this paper, we propose the ergonomic design method in shape design applicable for Advanced Urban Transit System. Human's sensitivity and User Interface of rolling stock investigated ergonomic studies of several type. The sensibility engineering design made approach of user center design in rolling stocks design. Therefore, we have application to properly of ergonomic design element in rolling stock design. we expert visual design and user interface help greatly in excellent rolling stock design.

  • PDF

지하철 이용 승객을 고려한 사용자 중심의 인간공학적 설계에 관한 연구 (The ergonomic design that considers the user interfaces in the railroad)

  • 박성혁;오세찬;여민우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.415-416
    • /
    • 2006
  • In this paper, we propose the ergonomics design method in shape design applicable which considers the user interface for railroad. This study focuses on ergonomics design and sensibility engineering design, user interface, which should be considered from the conceptual design stage of the rolling. Human's sensitivity and User Interface of railroad investigated ergonomics studies of several type. The sensibility engineering design made approach of user center design in railroad design. New design railroad to satisfaction passenger's various desire, to safety and convenient through high technology, to sufficient passenger's aesthetic sense. Therefore, we have application to properly of ergonomics design element in railroad design. we expert visual design and user interface help greatly in excellent railroad design.

  • PDF

The Improvement of Usability for Train Toilet Design

  • Han Seok-Woo;Jin Mi-Ja
    • 디자인학연구
    • /
    • 제19권3호
    • /
    • pp.195-206
    • /
    • 2006
  • Design for improved usability is to understand products from the user's point of view so eventually to enhance the pleasantness users by reflecting it into the design. The philosophy of user-oriented design is an essence of human-centered product planning, and its application is more important for railway vehicle design, which is closely connected with everyday life. This study focused to define basic elements of train interior design concept, which considers convenience and comfort for passengers, by extracting and interpreting ergonomic requirements, as usability factors, of train toilet design. The study on user-oriented design of trains consists of the practice of sensibility engineering for the management of customers' emotions and its harmonious use on design, and aims on the embodiment of new ergonomic design. In the center, it has analyzed the criteria and characteristics of the user-oriented design and has concluded the design direction and components to a concrete idea and proposed prototypes, which may become a good example for train interior design later on. In addition, it proposes a direction, which may become a guideline of ergonomic design, to secure competition capacity. Moreover this study is concentrated on the physical environment and human behavior of train toilet users, on the analysis of factors necessary for adequate toilet design, and on the understanding of interface between its users. What is more, it proposes a module of development process and methods of approaching the interface. The study presents a design standard, under which the concrete data of the characteristics and practicable range and the convergent demands accelerate to the module could be confirmed and criticized. The study on the usability is going to contribute to more pleasant and comfortable train environments and consequently, it's going to create new values of increased railway competitiveness by design.

  • PDF

냉장고 설계의 인간요소와 인간공학적 평가방법 (Human Factors and Evaluation methods of Refrigerator Design)

  • 박재희;황민철;박세진;김명석;안영진
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1998년도 춘계학술대회논문집
    • /
    • pp.19.1-24
    • /
    • 1998
  • Designers often hesitate to decide the shape, size, and layout of a product. Though ergonomic principles and data are absolutely needed in this process, they don't have enough guidelines to refer. For the refrigerator designers, they also are not convinced of their decision: the vertical position of the freezing and refrigerating rooms, the height of shelves, the shape of door-handle, and etc. To support the refrigerator design, we applied several ergonomic methods to the evaluation of a refrigerator. EMG measurement was used to evaluate the load of user's lumbar muscle. Based upon the experimental EMG data, we developed a model to predict the relative load according to the height of refrigerator shelves. Two different layouts of a refrigerator, R/F and F/R style, were compared with the model. A three-dimenaional motion analysis method was used to evaluate the user's motion of using a refrigerator. Ten door-handles with the different shapes and positions were evaluated by tracking the rotations of the user's arm. Video protocol analysis was used to evaluate the user interface of a control panel in a refrigerator. Finally, we made several ergonomic design guidelines based on the facts found in this research and the anthropometric data of the Korean adults. The results of this study can be applied to the ergonomic design of a refrigerator.

  • PDF

조종적성 검사/연구 장비 운용 Console의 인간공학적 개선 (Ergonomic Improvement of Operation Console for Pilot Aptitude Research Equipment)

  • 김성호
    • 산업경영시스템학회지
    • /
    • 제41권4호
    • /
    • pp.42-49
    • /
    • 2018
  • Pilot Aptitude Research Equipment (PARE) is a simulator developed to measure or research pilot aptitude and train for student pilots. Design of an ergonomic PARE operation console is required to operate the equipment effectively. This study carried out five steps : (S1) operator questionnaire survey, (S2) anthropometric design formula development, (S3) usability evaluation, (S4) improvement design, and (S5) validation considering both Physical User Interface (PUI) and Graphic User Interface (GUI) of PARE operation console. The operator questionnaire surveyed needs for each PUI and GUI part of the console from two PARE actual operators. In terms of PUI, the anthropometric design formula was developed by using design variables, body dimensions, target population characteristics, and reference posture related to the PARE console. In terms of GUI, the usability evaluation was conducted by three usability testing experts with a 7-point scale (1 : very low, 4 : neutral, 7 : very high) on GUI of the PARE operation console by seven usability criteria. The improved PARE operation console was designed to reflect the optimal values of design variables calculated from design formula, the results from usability testing, and the operator's needs. The improvement effect was observed by 20 people who had experience with the PARE operation console. As a result of the validation, monitor visibility and cockpit visibility for the improved PUI design and visibility and efficiency for the improved GUI design were significantly increased by more than 90% respectively. The improved design of the PARE operation console in this study can contribute to enhance operation performance of the PARE.

A Framework for Designing Closed-loop Hand Gesture Interface Incorporating Compatibility between Human and Monocular Device

  • Lee, Hyun-Soo;Kim, Sang-Ho
    • 대한인간공학회지
    • /
    • 제31권4호
    • /
    • pp.533-540
    • /
    • 2012
  • Objective: This paper targets a framework of a hand gesture based interface design. Background: While a modeling of contact-based interfaces has focused on users' ergonomic interface designs and real-time technologies, an implementation of a contactless interface needs error-free classifications as an essential prior condition. These trends made many research studies concentrate on the designs of feature vectors, learning models and their tests. Even though there have been remarkable advances in this field, the ignorance of ergonomics and users' cognitions result in several problems including a user's uneasy behaviors. Method: In order to incorporate compatibilities considering users' comfortable behaviors and device's classification abilities simultaneously, classification-oriented gestures are extracted using the suggested human-hand model and closed-loop classification procedures. Out of the extracted gestures, the compatibility-oriented gestures are acquired though human's ergonomic and cognitive experiments. Then, the obtained hand gestures are converted into a series of hand behaviors - Handycon - which is mapped into several functions in a mobile device. Results: This Handycon model guarantees users' easy behavior and helps fast understandings as well as the high classification rate. Conclusion and Application: The suggested framework contributes to develop a hand gesture-based contactless interface model considering compatibilities between human and device. The suggested procedures can be applied effectively into other contactless interface designs.

햅틱 인지 요인 분석을 적용한 진동 촉감 인터페이스 설계 프로세스 제안 (Design Process Suggestion of Vibrotactile Interface applying Haptic Perception Factor Analysis)

  • 허용해;김승희
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권5호
    • /
    • pp.79-87
    • /
    • 2021
  • 본 연구에서는 인간의 촉감 메커니즘을 반영하여 햅틱 인지 요인을 적용할 수 있는 진동 촉감 인터페이스 설계 프로세스를 제안하였다. 본 프로세스는 총 4단계로 햅틱 감각의 요구사항 분석 단계, 햅틱 요소 분석 단계, 햅틱 인지 요인분석 단계, 햅틱 요구사항 상세 설계 및 시제품 구현 단계로 구성된다. 본 설계 프로세스의 장점은 햅틱 인지 요인 분석을 적용함으로써 사용자 요구사항 도출 및 구현 시 불필요한 작업들을 배제할 수 있으며, 가장 큰 특징은 인체공학적 특징을 설계에 반영할 수 있고, 사용자 평가와 사용성 테스트, 햅틱 기능 최적화 작업을 동시에 수행함으로써 시제품 개발이 완료됨과 동시에 햅틱 요구사항 명세서가 완료된다는 것이다. 본 설계 프로세스는 사용자의 요구사항에서부터 햅틱 기능 상세설계 및 시제품 구현에 대한 전체 단계를 포함하고 있어 햅틱에 대한 전문 지식이 부족한 일반 개발자들도 사용자 중심의 설계가 가능하여 일정 수준 이상의 햅틱 기능 설계 및 구현을 가능케 할 것으로 기대된다.

직접조작방식 입력장치의 성능비교 (Evaluating the performance of direct manipulation input devices)

  • 박재희;이남식
    • 대한인간공학회지
    • /
    • 제11권1호
    • /
    • pp.103-109
    • /
    • 1992
  • Direct manipulations are composed of pointing operations and dragging operations. In order to find the optimum design parameters (such as C/D ratio, moving direction) for the direct manipulation of a GUI(Graphical User Interface), an ergonomic experiment was devised (2*4*3*8 design) to measure the performance of a mouse (Microsoft) and a trackball (Logitech). The results showed that the mouse was more suitable for the direct manipulation (expecially for the dragging operation) than the trackball, and the suitable C/D ratio was 10 (for the mouse) and 16 (for the trackball). Also the movement direction was a determinant factor in trackball performance.

  • PDF

고령자를 고려한 내비게이션의 인간공학적 설계에 관한 연구 (Ergonomic Designs of Car Navigation for Elderly Users)

  • 김창균;최재호;임영재;정의승
    • 대한인간공학회지
    • /
    • 제29권5호
    • /
    • pp.771-782
    • /
    • 2010
  • Today, the number of elderly drivers who use navigation is increasing with the growing number of elderly drivers. The purpose of this study is to provide guidelines on the interface of car navigation for elderly users. To extract significant factors which were distinguished between young and elderly users, both young and elderly users executed the driving test by installing two car navigation alternatives. The analysis was conducted through t-test. The results show that significantly different factors were the number and the meaning of the menu items in the initial screen, the location and the meaning of the menu icons in the map screen, the ease of search of the menu and the text size in the menu screen. Improvements for the factors of the initial screen and map screen were made with reference to ergonomic guidelines, and suggested through experiments comparing design alternatives for the menu screen. Design alternatives were made through a combination of investigative variables, and the analysis was conducted through ANOVA. The results show that Alternative 7 (the location of the tab was placed at the bottom, menu representation was done with the text font size of 18pt and the location of menu navigation icons was shown at the upper left) was preferred in terms of user's preference and the execution time. So if the suggested menu for elderly users are added to the existing design, both users will satisfy their desires. The guidelines suggested in this study will help the designer of car navigation take elderly users into consideration.