Tensile Bond Strength of Composite Resin Treated with Er:YAG Laser (Er:YAG 레이저를 활용한 와동형성시 컴포짓 결합강도)

  • Shin, Min;Ji, Young-Duk;Rhu, Sung-Ho;Cho, Jin-Hyoung
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.269-276
    • /
    • 2005
  • This in vitro study evaluated the influence of a flowable composite resin on the tensile bond strength of resin to enamel and dentin treated with Er:YAG laser and diamond bur. 96 Buccal enamel and mid-coronal dentin were laser-irradiated using an Er:YAG laser and treated with diamond bur. Each groups(48) were divided two small groups depends on acid-etching procedure. Light-cure flowable resin(Metafil Flo) and self-cure resin(Clearfil FII New Bond) were used in this study. After surface etching with 37% phosphoric acid and the application of an adhesive system, specimens were prepared with a hybrid composite resin. After 24hours storage in distilled water at 37$^{\circ}C$, all samples were submitted to the tensile bond strength evaluation, using a universal testing machine(Z020, Zwick, Germany). The obtained results were as follows: 1. TBS of acid-etching group were higher than those of non-etching group in both enamel and dentin treated with Er:YAG laser and diamond bur. Laser 'conditioning' was clearly less effective than acid-etching. Moreover, acid etching lased enamel and dentin significantly improved the microTBS of M-Flo. 2. In enamel, TBS of laser-irradiated group were lower than those of bur-prepared group. However, in flowable resin subgroup, there were not differed those between two groups in dentin. 3. In laser-treated group, TBS of flowable composite resin were higher than those of self-curing resin in dentin, however, there was no difference in enamel. From this study, we can conclude that the self- and light-cure composite resin bonded significantly less effective to lased than to bur-cut enamel and dentin, and that acid-etch procedure remains mandatory even after laser ablation. We suggest that Er:YAG laser was useful for preparing dentin cavity with flowable resin filling.

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

ER: YAG LASER IRRADIATED IMPLANT SURFACE OBSERVATION WITH SCANNING ELECTRON MICROSCOPY (Er: YAG 레이저 조사 임프란트 표면에 대한 전자주사현미경관찰)

  • Choi, Jung-Goo;Choi, Su-Jin;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Kyung-Hwan;Choi, Moon-Ki;Lee, June;Oh, Se-Ri
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.540-545
    • /
    • 2008
  • Since mid 20th century, dental treatments with laser have been introduced and improved a lot. Because early $CO_2$, Nd:YAG, diode, argon, and holmium lasers are used for dealing soft tissue, so it applied just limited field. But, in 1997 the lasers of erbium family that able to dealing soft and hard tissue also were introduced, laser application fields are enlarged. In today, the application fields reach on implantation treatment, so clinicians can use the laser to make holes for implantation, and flap elevation, even though treating peri-implantitis. So our class want to discover the optimal setting of Er:YAG laser when treating peri-implantitis. We observed the surface that initially treated by RBM and TPS passion and laser with varied options of exposure time and power with SEM image. For this we conclude the optimal setting range that does not alter the implant surface structure and report it.

Efficiency of ceramic bracket debonding with the Er:YAG laser (세라믹 브라켓의 제거 시 Er:YAG 레이저의 효능)

  • Suh, Chung-Hwan;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.213-224
    • /
    • 2009
  • Objective: The aim of this study was to find out whether Er:YAG laser can aid in debonding ceramic brackets, and to see what kind of method will be the most appropriate for debonding. Methods: One hundred and ninety teeth, monocrystalline brackets ($MISO^{TM}$, HT, Ansan-Si, Korea), polycrystalline brackets ($Transcend^{TM}$ series 6000, 3M Untek, Monrovia, CA, USA) and the KEY Laser3 (KavoDental, Biberach, Germany) were used. Experimental groups were classified according to the type of ceramic brackets, and the amount of laser energy (0, 140, 300, 450, 600 mJ). After applying laser on the bracket at two points at 1 pulse each, the shear bond strength was measured. The effect of heat caused by laser was measured at the enamel beneath the bracket and pulp chamber. After measuring the shear bond strength, adhesive residue was evaluated and enamel surface was investigated using SEM. Results: All ceramic bracket groups showed a significant decrease in shear bond strength as the laser energy increased. The greatest average temperature change was $3.78^{\circ}C$ on the enamel beneath the bracket and $0.9^{\circ}C$ on the pulp chamber. Through SEM, crater shape holes caused by the laser was seen on the enamel and adhesive surfaces. Conclusions: If laser is applied on ceramic brackets for debonding, 300 - 450 mJ of laser energy will be safe and efficient for monocrystalline brackets ($MISO^{TM}$), and about 450 mJ for polycrystalline brackets ($Transcend^{TM}$ series 6000).

Comparative Study of the Ablation Rates of Er: YAG Laser Irradiation on Dentin and Enamel (Er:YAG 레이저를 이용한 법랑질과 상아질의 절삭율 연구)

  • Kim, Kun-A;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.131-140
    • /
    • 2005
  • The purpose of this study was to examine the ablation rate of Er: YAG laser irradiation on dentin and enamel and to observe the microscopic structures of cavities formed after ablation of enamel and dentin in using a bur and cavities formed after ablation using laser. Er:YAG laser irradiated at 200 mJ, 250mJ, 300mJ at the frequency of 20Hz, 15Hz. The following results were obtained : 1. The ablation rate of dentin groups at power of 3 W-6 W was about $1.103{\sim}2.639mm^3/sec$ and there were no significant differences between power of 4.5 W$\sim$6 W. 2. The ablation rate of enamel groups at power of 3 W-6 W was about $0.413{\sim}0.969mm^3/sec$ and there were no significant differences between power of 4 W$\sim$6 W. 3. With SEM examination of the cavity surface treated with the conventional high speed bur revealed relatively flat appearance almost covered with a debris like smear layer. 4. With SEM examination of the lased surface of dentin groups revealed no smear layer and no debris and openings of dentinal tubules were clearly opened. But the lased surfaces of the groups over 3 W were irregular and particles were loosely attached on it. 5. With SEM examination of the lased surface of enamel groups revealed severely destructed surface at the 6 W group and melting drop materials at the 3 W group. But the lased surface of 4 W group revealed clearly ablated surface. Therefore when cutting teeth using Er:YAG laser, the lasing power which can make effective ablation rate and minimize the thermal effect could be 3W at dentin and 4W at enamel. But, further studies and additional data collection will be necessary for appropriate lasing condition of Er:YAG laser.

Mechanical Properties of Hot-Pressed SiC with Rare-Earth Oxide (희토류 산화물을 첨가한 일축가압소결 탄화규소의 기계적 특성)

  • 최철호;이충선;박광자;조덕호;김영욱
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.2
    • /
    • pp.158-163
    • /
    • 2000
  • Six different SiC ceramics with SiO2-Re2O3 (Re=Yb, Er, Y, Dy, Gd, Sm) as sintering additives have been fabricated by hot-pressing the SiC-Re2Si2O7 compositions at 1850$^{\circ}C$ for 2 hr under a pressure of 25 MPa. The room temperature strneth and the fracture toughness of the hot-pressed ceramics were characterized and compared with those of the ceramics sintered with YAG (Y3Al5O12). Five SiC ceramics (Re=Yb, Er, Y, Dy, Gd) investigated herein showed sintered densities higher than 94% of theoretical. Tthe SiC-Re2Si2O7 compositions showed lower strength and comparable toughness to those from SiC-YAG composition, owing to the chemical reaction between SiO2 and SiC during sintering. SiC ceramics fabricated from a SiC-Y2Si2O7 composition showed the best mechanical properties of 490 MPa and 4.8 MPa$.$m1/2 among the compositions investigated herein.

  • PDF

Modeling of Pulsed Laser Heating of Tissue: Implications or Skin Resurfacing (Pulsed Laser를 이용한 생체조직 가열을 위한 모델링 : Skin Resurfacing을 위한 연관성)

  • Kwon, Y.H.;Rastegar, S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.375-379
    • /
    • 1997
  • Pulsed Er:YAG and $CO_2$ lasers induced temperature rise of tissue are studied using axisymmetric, two-dimensional, and transient Pennes' bio-heat equation or the implications of skin resurfacing. Model results indicate that Er:YAG laser induced temperature has much higher but more shallow distribution in tissue than that of the $CO_2$ laser because of its higher absorption coefficient. The increase of repetition rate does not affect the temperature rise too much because these laser modalities have much shorter heat diffusion time than the temporal length of each off-pulse. This model works as a tool to understand the photothermal effect in the laser-tissue interaction.

  • PDF

A PRELIMINARY STUDY OF PULSED LASER HEATING OF TISSUE FOR THE IMPLICATIONS OF SKIN RESURFACING

  • Kwon,Yong-Hoon;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.5 no.1
    • /
    • pp.39-43
    • /
    • 1998
  • Pulsed Er: YAG and CO$_2$ lasers induced temperature rise of tissue is studied using axisymmetric, two-dimensional, and transient Pennes bio-heat equation for elucidating the implications of skin resurfacing. Modeling indicates that Er:YAG laser induced temperature has much higher but more shallow distribution in tissue than that of the CO$_2$ laser because of much higher absorption coefficient. The increase of repetition rate does not much affect on temperature rise because these laser modalities have much shorter heat diffusion time than the temporal length of each off-pulse. This model works as a tool to understand the photothermal effect in the laser-tissue interaction.

  • PDF

A Design and Implementation of 30w class Er:YAG laser adopted skin and dental clinic. (치과 및 교부과용 30W급 Er:YAG 레이저 설계 및 구현)

  • 김휘영;신경애
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.211-214
    • /
    • 2001
  • For general laser power supply, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is connected to a switching element in the secondary of the transformer. So the Dower supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition, charged energy of energy-storage capacitor is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this raper, to improve laser efficiency, we designed and fabricated the power supply in which the SCR was turned on in zero point by the methods of ZCC(zero crossing control), PFN(pulse forming network) in result, laser output efficiency increased by hte 4% other than conventional supply, when a repetition rate was increased by the 10[pps], In 20(pps), efficiency was increased by about 8%