• 제목/요약/키워드: Equivalent power distribution

검색결과 154건 처리시간 0.026초

분산형전원이 도입된 배전계통의 리얼타임 최적전압조정을 위한 부하구간 모델링방법 (A Modeling Method of Load Section on High Voltage Distribution Line Integrated with Dispersed Generation System for Real-Time Optimal Voltage Regulation)

  • 김재언;김태응
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.699-703
    • /
    • 1999
  • It is known that the LDC(Line-Drop Compensator) becomes to lose the function of proper voltage regulation for its load currents due to the real and reactive power generated by DGS(Dispersed Generation System), when DGS is introduced into the power distribution system of which the voltage is controlled by LDC. Therefore, in that case, it is very difficult to regulate the distribution line voltage properly by using LDC. One possible solution for this problem is the real-time voltage regulation method which is to optimally regulate the sending-end voltage in real-time by collecting the real-time load data of each load data of each load section between measuring points and by calculating the optimal seding-end voltage value from them. For this, we must know the real-time load data of each load section. In this paper, a modeling method of representing a load section on high voltage line with DGSs as an equivalent lumped load is proposed for gaining the real-time load data. In addition a method of locating the measuring points is proposed. Then, these proposed methods are evaluated through computer simulations.

  • PDF

선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발 (The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances)

  • 문영현;조병훈;노태훈;최병곤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

병행 배전선로에서의 통신선 유도전압 계산 (Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines)

  • 김현수;이상봉;여상민;김철환;류승헌;김성암;원봉주
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

철도차량용 회전형 축소모델 선형유도전동기의 운전모드 연구 (A Study on an Operation Mode of a Rotary-type Small-scaled LIM for Railway Transit)

  • 박찬배;이병송;이형우;권삼영;박현준;한경희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.310-315
    • /
    • 2008
  • Authors design a rotary-type small-scaled linear induction motor(LIM) and a performance test machine before manufacturing a real-scaled LIM for a railway transit. The designed LIM is a single-sided, short primary type and its primary has 4 poles. The rated power is 10(kW). In order to analyze characteristics of the LIM, authors use a mixed 2D-3D FEM analysis. 3-D FEM analysis is used for calculating a distribution of eddy-current on the semi-caped AL-sheet of the secondary reaction. Authors calculate a correction factor of conductivity and an equivalent conductivity on the secondary AL-sheet using a normalized eddy-current. The equivalent conductivity which is calculated in this way includes a transverse edge-effect of the LIM. Authors apply the equivalent conductivity on the secondary AL-sheet of 2D-FEM model and get performance characteristics of the LIM. Basic characteristics such as thrust and normal force, input current, efficiency and power factor of the LIM have been analyzed with the variation of frequency and speed. In order to apply an air-gap control system, the variation of the basic characteristics have been analyzed with the air-gap length variation of the LIM. Finally, authors introduce an operation mode using the air-gap control system and conduct a research on feasibility of the system.

  • PDF

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

전자기펌프의 설계 및 액체금속 유동의 수치해석 (Design of an Electromagnetic Pump and Numerical Analysis of the Liquid Metal Flow)

  • 권정태;김서현;남택훈;임효재;김창업
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2589-2595
    • /
    • 2009
  • 본 연구에서는 장하분배법(Load Distribution Method) 및 등가회로법(Equivalent Circuit Method)을 이용하여 액체금속이송을 위한 전자기펌프를 설계하고 제작하였다. 제작된 전자기펌프의 구동전력과 이에 상응하는 액체의 유량관계를 구하였다. 액체금속유동에 가하는 전자기 힘(Lorentz force)의 크기에 따른 유속과 유량을 수치해석기법을 이용하여 계산하였다. 수치해석결과를 상용코드인 FLUENT를 이용하여 계산한 결과와 비교하고 분석하였다. 다양한 전자기력의 크기에 대한 액체금속(우드메탈)의 평균속도에 대한 결과는 FLUENT의 결과와 5%이내의 오차 내에서 잘 일치하였다.

이중 주파수 전원의 용량성 결합 플라즈마 식각장비에서 전극하전에 의한 입사이온 에너지분포 변화연구 (Electrode Charging Effect on Ion Energy Distribution of Dual-Frequency Driven Capacitively Coupled Plasma Etcher)

  • 최명선;장윤창;이석환;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제13권3호
    • /
    • pp.39-43
    • /
    • 2014
  • The effect of electrode charging on the ion energy distribution (IED) was investigated in the dual-frequency capacitively coupled plasma source which was powered of 100 MHz RF at the top electrode and 400 kHz bias on the bottom electrode. The charging property was analyzed with the distortion of the measured current and voltage waveforms. The capacitance and the resistance of electrode sheath can change the property of ion and electron charging on the electrode so it is sensitive to the plasma density which is controlled by the main power. The ion energy distribution was estimated by equivalent circuit model, being compared with the measured distribution obtained from the ion energy analyzer. Results show that the low frequency bias power changes effectively the low energy population of ion in the energy distribution.

부하불평형 및 부하모형을 고려한 복합배전계통의 분산형전원의 연계 방안 (Interconnection of Dispersed Generation Systems considering Load Unbalance and Load Model in Composite Distribution Systems)

  • 이유정;김규호;이상근;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권5호
    • /
    • pp.266-274
    • /
    • 2004
  • This paper presents a scheme for the interconnection of dispersed generator systems(DGs) based on load .unbalance and load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The unbalance is involved with many single-phase line segment. . Voltage profile improvement and system loss minimization by installation of DGs depend greatly on how they are placed and operated in the distribution systems. So, DGs can reduce distribution real power losses and replace large-scale generators if they are placed appropriately in the distribution systems. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 13 bus and 34 bus test systems to demonstrate its effectiveness.

기후 분포와 모듈 사양를 고려한 태양광 발전의 출력량 분포 분석 (an Analysis of PV Power Output Considering the Distribution of Weather Condition and the spec of module)

  • 조성민;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.492_493
    • /
    • 2009
  • In this paper, we analyzed relation between weather distribution and output of PV module. Equivalent circuit of PV module was derived. Output of PV array was calculated considering temperature and insolation as input. Output of PV array installed on the roof top was also measured. Then, comparison between results was carried out to verify that relation between input and output is appropriate. Distribution of insolation and temperature was derived from KMA (Korea Meteorological Administration). Distribution of PV output was deduced, by considering weather distribution. The result of this paper can be used in economic analysis and reliability calculation.

  • PDF

가솔린 엔진개조 CNG 발전기 개발과 동급 디젤엔진의 배출가스 특성 연구 (Development of Gasoline Engine Renewal CNG Generator and a Study on Exhaust Gas Characteristics of Equivalent Diesel Engine)

  • 이정천;김기호;이정민;박언영
    • 동력기계공학회지
    • /
    • 제22권6호
    • /
    • pp.74-79
    • /
    • 2018
  • Compressed natural gas has a high octane number and low particulate emission characteristics as compared with petroleum-based fuels, so it can respond to exhaust gas regulations positively. A natural gas engine has been introduced to improve the quality of the atmosphere, a diversity of fuel, a stable supply, and it has widely been used in city buses and garbage trucks. Recently, the natural gas engine has received attention by overcoming the disadvantage of the theoretical air-fuel ratio method through the development of EGR cooler and engine parts with the development of LP-EGR technology. In this study, we try to develop the cogeneration system that can simultaneously generate electric power and heat by remodeling the gasoline engine to the mixer type CNG engine. As a result, it was able to reduce the NOx (approximately 77%) compared to the diesel engines with same displacement.