• 제목/요약/키워드: Equivalent noise

검색결과 616건 처리시간 0.025초

로젯 주사 적외선 탐색기의 순시 시계 설계에 관한 연구 (A study on design of instantaneous field of view of rosette scanning infrared seeker)

  • 장성갑;홍현기;한성현;최종수
    • 전자공학회논문지S
    • /
    • 제35S권7호
    • /
    • pp.86-94
    • /
    • 1998
  • The rosette-scan seeker is a device mounted on the infrared guided missile. It offers the positions and iamges of target to missiles servo system by scanning a space about target in rosette pattern with a single detector. An instantaneous field of view (IFOV), which is a diameter of a detector moving along the path of the rosette pattern, has the property that its smaller size provide the less interference of background signals and detector noise. If its size is too small to voer the total field of view (TFOV), however, it produces the invisible regions in the TFOV. In this case, the invisible regions cause the performance of the seeker to deteriorate. For full scan-coverage, it is necessary to design the small IFOV without the invisible regions in the TFOV, as possible. In this paper, we propose the new method of designing the smaller IFOV than the conventional method and verify full coverage of the scanned region. By comparing the nose equivalent flux density (NEFD) of the proposed method with the that of the conventional one, we confirm that the former is better than the latter in terms of performance.

  • PDF

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제36권5호
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

Dynamic response of adjacent structures connected by friction damper

  • Patel, C.C.;Jangid, R.S.
    • Earthquakes and Structures
    • /
    • 제2권2호
    • /
    • pp.149-169
    • /
    • 2011
  • Dynamic response of two adjacent single degree-of-freedom (SDOF) structures connected with friction damper under base excitation is investigated. The base excitation is modeled as a stationary white-noise random process. As the force-deformation behavior of friction damper is non linear, the dynamic response of connected structures is obtained using the equivalent linearization technique. It is observed that there exists an optimum value of the limiting frictional force of the damper for which the mean square displacement and the mean square absolute acceleration responses of the connected structures attains the minimum value. The close form expressions for the optimum value of damper frictional force and corresponding mean square responses of the coupled undamped structures are derived. These expressions can be used for initial optimal design of the friction damper for connected structures. A parametric study is also carried out to investigate the influence of system parameters such as frequency ratio and mass ratio on the response of the coupled structures. It has been observed that the frequency ratio has significant effect on the performance of the friction damper, whereas the effects of mass ratio are marginal. Finally, the verification of the derived close from expressions is made by correlating the response of connected structures under real earthquake excitations.

State Estimation Technique for VRLA Batteries for Automotive Applications

  • Duong, Van Huan;Tran, Ngoc Tham;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.238-248
    • /
    • 2016
  • The state-of-charge (SOC) and state-of-health (SOH) estimation of batteries play important roles in managing batteries for automotive applications. However, an accurate state estimation of a battery is difficult to achieve because of certain factors, such as measurement noise, highly nonlinear characteristics, strong hysteresis phenomenon, and diffusion effect of batteries. In certain vehicular applications, such as idle stop-start systems (ISSs), significant errors in SOC/SOH estimation may lead to a failure in restarting a combustion engine after the shut-off period of the engine when the vehicle is at rest, such as at a traffic light. In this paper, a dual extended Kalman filter algorithm with a dynamic equivalent circuit model of a lead-acid battery is proposed to deal with this problem. The proposed algorithm adopts a battery model by taking into account the hysteresis phenomenon, diffusion effect, and parameter variations for accurate state estimations of the battery. The validity of the proposed algorithm is verified through experiments by using an absorbed glass mat valve-regulated lead-acid battery and a battery sensor cable for commercial ISS vehicles.

새로운 DGS구조를 이용한 자기 발진 혼합기 설계 (Design of A Self-Oscillating Mixer Using A Novel DGS)

  • 정명섭;김종옥;박준석;임재봉;김형석;조홍구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1958-1960
    • /
    • 2003
  • Here we describe a unique self-oscillating mixer (SOM) design using a modified defected ground structure (DGS) for down-converter. Proposed SOM is consisted of self-oscillator, which can produce negative resistance and select resonance frequency, and input/output matching filter. As the advantage of this SOM can be reused by module that mix signals with transistor that is used to oscillator, it is simply and low-costly designed Also, there is easy advantage to be applied in RFIC/ MMIC technology because it offers excellent high Q value in spite of using micro-strip structure. Designed self-oscillating frequency is 1.04GHz and RF frequency established is 0.8GHz. It was achieved 20dB conversion loss and phase noise of -95dBc/Hz at 100KHz offset frequency over intermediate frequency (IF). The equivalent circuit parameters for DGS are extracted by using a three dimensional EM simulator and simple circuit analysis method.

  • PDF

Investigation of ITU Radio Regulations Regarding KPS Service Band

  • Subin Lee;Kahee Han;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권2호
    • /
    • pp.177-184
    • /
    • 2023
  • In order to reserve frequency bands for stable operation of the Korean Positioning System (KPS), it must be demonstrated that the impact of interference caused by KPS on other services operating in the same bands is tolerable. The International Telecommunication Union (ITU) provides the radio regulations and a compatibility assessment methodology for the coexistence of different services in limited frequency resources. The purpose of this paper is to investigate the radio regulations regarding the compatibility issues between the KPS and other services sharing the same frequency bands. The results of the investigation show that the RNSS system can be operated in the L5-band under the condition that the Power Flux Density (PFD) and Aggregated Equivalent PFD (AEPFD) thresholds specified in the radio regulations are met. In addition, the ITU recommends that the interference-to-noise ratio (INR) protection criteria be met to prevent degradation of the performance of radar systems operating in the L2/L6-band. In the case of the S-band, coordination of allocations for RDSS space stations with respect to terrestrial services is not required if the PFD does not exceed regulated thresholds regulated by ITU.

0.25 ㎛ GaAs pHEMT 공정을 이용한 X-대역 코아-칩의 설계 (Design of X-band Core Chip Using 0.25-㎛ GaAs pHEMT Process)

  • 김동석;이창대;이동현;염경환
    • 한국전자파학회논문지
    • /
    • 제29권5호
    • /
    • pp.336-343
    • /
    • 2018
  • 본 논문에서는 Win 사의 상용 $0.25{\mu}m$ GaAs pHEMT 공정 기술을 이용하여 X-대역(10.5~13 GHz)에서 동작하는 수신부 코아-칩의 설계 및 제작을 보였다. X-대역 코아-칩은 저잡음증폭기, 4-비트 위상천이기, 직렬-병렬 컨버터(SPC: Serial to parallel data converter)로 구성되며, 크기는 $1.75{\times}1.75mm^2$로 지금까지 보고된 코아-칩 중 가장 소형의 크기를 갖는다. 사용 주파수 대역에서 이득 및 잡음지수는 각각 10 dB 이상, 2 dB 미만, 입출력 반사손실은 10 dB 미만이다. RMS 위상 오차는 12.5 GHz에서 $5^{\circ}$ 미만, P1dB는 2 dBm으로 타 코아-칩과 대등한 성능을 갖는다. 제작된 코아칩은 조립의 편의를 제공하기 위해 $3{\times}3mm^2$ 크기를 갖는 QFN 패키지로 패키지되었으며, 패키지된 코아-칩의 성능은 칩-자체의 성능과 거의 같음을 확인하였다.

1,3 Propanediol을 이용해 제작된 PZT(30/70) 후막의 초전특성에 관한 연구 (A Study on the Pyroelectric Properties of PZT(30/70) Thick film Prepared by Using 1,3 Propanediol)

  • 송금석;장동훈;정양희;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제41권6호
    • /
    • pp.9-15
    • /
    • 2004
  • 1,3 propanediol 을 이용한 sol-gel 방법으로 PZT(30/70) 후막을 제작하였다. 제작된 film 의 초전특성은 dynamic 방법을 이용하여 변조 주파수 의존성을 조사하였다. 초전계수 (pyroelectric coefficient) 는 약 $5.0{\times}10^{-8}\;C/cm^2{\cdot}K$를 나타내었다. 전압감도와 비검출능에 대한 재료평가지수는 비교적 높은 유전률과 높은 초전계수로 인해 각각 $3.4{\times}10^{-11}\;C{\cdot}cm/J$$5.9{\times}10^{-9}\;C{\cdot}cm/J$을 나타내었다. 전압감도는 저주파 영역에서 증가하다가 고주파 영역에서는 주파수에 반비례하는 경향을 보이며, 10Hz에서 최대값 1.84 V/W를 나타내었다. 잡음전압은 Johnson 잡음의 영향으로 거의 $f^{-1/2}$ 에 비례하여 증가하였다 잡음등가전력과 비검출능은 같은 주파수 80Hz 에서 각자 $2.83{\times}10^{-7}\;W/Hz^{1/2}$3.13{\times}10^5\;cm{\cdot}Hz^{1/2}/W$를 나타내었다.

향상된 전력효율을 갖는 GaInP/GaAs HBT 마이크로파 푸쉬-푸쉬 전압조정발진기 (A Microwave Push-Push VCO with Enhanced Power Efficiency in GaInP/GaAs HBT Technology)

  • 김종식;문연국;원광호;신현철
    • 대한전자공학회논문지SD
    • /
    • 제44권9호
    • /
    • pp.71-80
    • /
    • 2007
  • 본 논문은 교차결합된 부성저항(cross-coupled negative-gm) 발진기 구조의 캐패시터 공통단자에서 2차 고조파를 얻어내는 새로운 푸쉬-푸쉬 기술에 대해 제안한다. 캐패시터 공통단자에서 2차 고조파가 생성되는 기본적인 이론은 에미터-베이스 접합 다이오드의 비선형 특성에 의한 Voltage clipping과 VCO core 트랜지스터의 Switching 동작 시 생기는 상승과 하상 시간의 차로써 설명된다. Simulation을 통한 비교연구를 통하여 본 논문에서 제안한 방법이 기존의 에미터 공통단자에서 출력을 얻어내는 방법보다 마이크로파 영역에서 전력효율이 더 뛰어나다는 것을 보였다. 본 기술을 적용한 Prototype MMIC VCO가 12-GHz와 17-GHz 대역에서 GaInP/GaAs HBT 공정을 사용하여 설계, 제작되었다. 출력 파워는 각각 -4.3dBm과 -5dBm이 측정되었고, Phase noise는 1-MHz offset에서 각각 -108 dBc/Hz와 -110.4 dBc/Hz가 측정되어 -175.8 dBc/Hz와 -184.3 dBc/Hz의 FoM(Figure-of-Merit)을 얻었다. 제작된 12-GHz와 17-GHz의 VCO Core는 각각 25.7mW(10.7mA/2.4V)와 13.1mW(4.4mA/3.0V)를 소모한다.

전신 뼈검사에서의 영상 평가 연구 (Study on Image Quality Assessment in Whole Body Bone Scan)

  • 권오준;허재;이한울;김주연;박민수;노동욱;강천구;김재삼
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.30-36
    • /
    • 2015
  • 전신 뼈검사는 골수염과 골절 및 원발성 암의 조기 발견 등골 병변에 대해 높은 민감도와 해상도를 가진 검사이며, 핵의학 검사 중 가장 많은 비중을 차지하고 있다. 그러나 최저 계수치를 제외한 평가 기준이 마련되어 있지 않다. 따라서, 본 연구에서 전신 뼈검사에서 정량적인 평가 지표를 나타낼 수 있는 방법을 분석해보고자 하였다. 본 연구는 2014년 4월부터 2014년 9월까지 본원을 내원한 특이 골병변소견이 없는 환자 30명을 대상으로 GE INFINIA 장비에서 진행하였다. 환자의 전신계수와 허리뼈를 관심영역으로 하여, 계수치를 측정하였으며, 허리뼈 각각의 신호평균 값과 표준편차를 구하여, 대조도 대 잡음비(Contrast to Noise Ratio, CNR), 신호 대 잡음비(Signal to Noise Ratio, SNR)를 산출하였고, 팬텀 실험을 통해 검사 속도 변화에 따른 각각의 수치와 조직등가물질을 이용하여 복부 두께에 따른 수치를 비교 하였다. 그리고, 판독의 2명과 5년 이상의 경력을 가진 숙련된 방사선사 5명이 각각 10점 척도로 하여, Blind test로 육안적인 분석치와 정량적인 산출치 간의 상관관계를 분석하였다. 환자의 전신 계수치와 관심영역의 계수치는 Blind test를 통한 육안적인 분석치와 유의한 상관관계를 보이지 않았다(P>0.05). 대조도 대 잡음비와 신호 대 잡음비는 육안적인 분석치와 유의한 상관관계를 보였다(P<0.05). 팬텀 실험에서는 검사 속도가 느릴수록, 조직등가물질의 두께가 얇을수록 각 수치는 향상되는 것을 보였으며, 지연검사에서 영상의 질이 향상됨을 확인하였다. 현재 전신 뼈검사에서 최저 계수치를 제외한 평가 기준이 마련되어있지 않다. 이에 본 연구에서는 대조도 대 잡음비 및 신호 대 잡음비를 이용하여 Blind test와의 유의한 상관관계를 확인 할 수 있었으며, 검사 속도가 영상의 질을 좌우하는 인자라는 것을 수치를 통해 확인하였다. 본 연구에서는 동일한 주입량, 동일한 검사 속도 등 동등한 조건에서의 평가를 진행하였지만, 환자의 생리적 기능과 수분 섭취량 등에 따라 모든 특성을 고려하는 것에 한계가 존재한다. 그러나 객관적으로 정량적 수치를 제시하여, 유의한 평가 지표를 입증하였다는 데에 학술적 의미가 있을 것으로 사료된다.

  • PDF