• 제목/요약/키워드: Equivalent noise

검색결과 616건 처리시간 0.027초

Extended SBM 공정을 이용하여 단일 실리콘 기판상에 제작된 새로운 z 축 가속도계 (A Novel z-axis Accelerometer Fabricated on a Single Silicon Substrate Using the Extended SBM Process)

  • 고형호;김종팔;박상준;곽동훈;송태용;조동일;허건수;박장현
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.101-109
    • /
    • 2004
  • This paper presents a novel z-axis accelerometer with perfectly aligned vertical combs fabricated using the extended sacrificial bulk micromachining (extended SBM) process. The z-axis accelerometer is fabricated using only one (111) SOI wafer and two photo masks without wafer bonding or CMP processes as used by other research efforts that involve vertical combs. In our process, there is no misalignment in lateral gap between the upper and lower comb electrodes, because all critical dimensions including lateral gaps are defined using only one mask. The fabricated accelerometer has the structure thickness of $30{\mu}m$, the vertical offset of $12{\mu}m$, and lateral gap between electrodes of $4{\mu}m$. Torsional springs and asymmetric proof mass produce a vertical displacement when an external z-axis acceleration is applied, and capacitance change due to the vertical displacement of the comb is detected by charge-to-voltage converter. The signal-to-noise ratio of the modulated and demodulated output signal is 80 dB and 76.5 dB, respectively. The noise equivalent input acceleration resolution of the modulated and demodulated output signal is calculated to be $500{\mu}g$ and $748{\mu}g$. The scale factor and linearity of the accelerometer are measured to be 1.1 mV/g and 1.18% FSO, respectively.

긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기 (Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer)

  • 이순걸;강찬석;김인선;김상재
    • Progress in Superconductivity
    • /
    • 제7권1호
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

무선 센서 네트워크에서 1-2-1 협력 프로토콜에 관한 연구 (Performance Analysis of 1-2-1 Cooperative Protocol in Wireless Sensor Networks)

  • 최대규;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권5호
    • /
    • pp.113-119
    • /
    • 2008
  • 기존의 1-1-1 협력 프로토콜은 멀티 홉이 가지고 있는 경로손실감소 이득과 함께 MIMO와 동일한 공간 다이버시티를 제공한다. 이를 통해 싱글 홈, 멀티 홉보다 뛰어난 정보의 신뢰도 및 에너지 소비 감소를 얻을 수 있다. 하지만 기존의 1-1-1 협력 프로토콜은 단일의 협력 중계기를 사용하므로 경로손실감소 이득과 다이버시티 이득 계수가 2로 제한되어 있다. 따라서 본 논문에서는 두개의 협력 중계기 R1, R2를 사용한 1-2-1 협력 프로토콜을 제안한다. 1-2-1 협력 프로토콜은 경로손실감소 이득을 높이고 계수가 3인 다이버시티 이득을 얻는다. 또한, 협력 중계가 R2에서도 계수가 2인 다이버시티 이득을 얻을 수 있다. 협력 중계기는 DF (Decode and Forward)와 DR (Decode and Reencode) 방식을 사용하여 1-2-1 DF 또는 DR 협력 프로토콜을 형성하고, 클러스터링 기반의 무선 센서 네트워크 (WSNs)에 적용한다. 제안한 프로토콜의 성능평가를 위해 레일리 페이딩과 AWGN (Additive White Gaussian Noise) 채널이 합해진 채널에서 모의실험을 한다.

  • PDF

$Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.1) (PLT(10)) 강유전체 박막에서 동적 초전특성의 주파수 의존성에 관한 연구 (A study on the Frequency Dependence of Dynamic Pyroelectric Properties for $Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.1) (PLT(10)) Ferroelectric Thin Film)

  • 차대은;장동훈;강성준;윤영섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.104-107
    • /
    • 2001
  • The fabricated La-modified lead titanate (PLT) thin flim without paling treatment was investigated for modulation frequency dependence of pyroelectric properties by the dynamic method. $Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ PLT (x=0.1) thin film having 10 mol% La content was deposited on a $Pt/TiO_{x}/SiO_{2}/Si$ substrate by sol-gel method. The PLT(10) thin film exhibits a relatively excellent dielectric property. The pyroelectric coefficient (p) of the PLT(10) thin film is $6.6{\times}10^{-9}C/cm_{2}\cdot K$ without frequency dependence. The figure of merits for the voltage responsivity and specific detectivity are $1.03{\times}10^{-11}C\cdot cm/J$ and $1.46\times 10^{-9}C\cdot cm/J$, respectively. The PLT(10) thin film has voltage responsivity (Rv) of 5.15 V/W at 8 Hz. Noise equivalent power (NEP) and specific detectivity (D*) of the PLT(10) thin film are$9.93{\times}10^{-8}W/Hz^{1/2}$ and $1.81\times 10^{6}cmHz^{1/2}/W$ at the same frequency of 100 Hz, respectively. The results means that PLT thin film having 10 mol % La content is suitable for the sensing materials of pyroelectric IR sensors.

  • PDF

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

M&S를 이용한 항공기용 통합형 전기식 구동장치의 동적 안전성 연구 (The Study of Dynamic Safety Using M&S for Integrated Electro-mechanical Actuator Installed on Aircraft)

  • 이석규;이병호;이증;강동석;최관호
    • 한국소음진동공학회논문집
    • /
    • 제25권2호
    • /
    • pp.108-115
    • /
    • 2015
  • Electro-mechanical actuator installed on aircraft consists of a decelerator which magnifies the torque in order to rotate an axis connected with aircraft control surface, a control section which controls the motor assembly through receiving orders from cockpit and a motor assembly which rotates the decelerator. Electro-mechanical actuator controls aircraft altitude, position, landing, takeoff, etc. It is an important part of a aircraft. Aircraft maneuvering causes vibrations to electro-mechanical actuator. Vibrations may result in structural fatigue. For that reason, it is necessary to analyze the system structural safety. In order to analyze the system structural safety. It is needed reasonable finite element model and structural response stress closed to real value. In this paper, analytic model is derived by using the simplified finite element model, and damping ratio which is closely related to response stress is derived by using modal test. So, we developed analytic model in less than 10 % error rate, compared with modal test. Vibration response stress close to real value was estimated from analytic model modified with modal experimental damping ratio. Estimation method for damping ratio with empirical formula was suggested partly. Finally, It was proved that electro-mechanical actuator had reasonable structure margin of safety at environmental random $3{\sigma}$ stress during life cycle.

Fast Ambiguity Resolution using Galileo Multiple Frequency Carrier Phase Measurement

  • Ji, Shengyue;Chen, Wu;Zhao, Chunmei;Ding, Xiaoli;Chen, Yongqi
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.179-184
    • /
    • 2006
  • Rapid and high-precision positioning with a Global Navigation Satellite System (GNSS) is feasible only when very precise carrier-phase observations can be used. There are two kinds of mathematical models for ambiguity resolution. The first one is based on both pseudorange and carrier phase measurements, and the observation equations are of full rank. The second one is only based on carrier phase measurement, which is a rank-defect model. Though the former is more commonly used, the latter has its own advantage, that is, ambiguity resolution will be freed from the effects of pseudorange multipath. Galileo will be operational. One of the important differences between Galileo and current GPS is that Galileo will provide signals in four frequency bands. With more carrier-phase data available, frequency combinations with long equivalent wavelength can be formed, so Galileo will provide more opportunities for fast and reliable ambiguity resolution than current GPS. This paper tries to investigate phase only fast ambiguity resolution performance with four Galileo frequencies for short baseline. Cascading Ambiguity Resolution (CAR) method with selected optimal frequency combinations and LAMBDA method are used and compared. To validate the resolution, two tests are used and compared. The first one is a ratio test. The second one is lower bound success-rate test. The simulation test results show that, with LAMBDA method, whether with ratio test or lower bound success rate validation criteria, ambiguity can be fixed in several seconds, 8 seconds at most even when 1 sigma of carrier phase noise is 12 mm. While with CAR method, at least about half minute is required even when 1 sigma of carrier phase noise is 3 mm. It shows that LAMBDA method performs obviously better than CAR method.

  • PDF

$Pb_{1-x}La_{x}Ti_{1-x/4}O_3$(x=0.1)(PLT(10)) 강유전체 박막에서 동적 초전특성의 주파수 의존성에 관한 연구 (A study on the Frequency Dependence of Dynamic Pyroelectric Properties for $Pb_{1-x}La_{x}Ti_{1-x/4}O_3$(x=0.1)(PLT(10)) Ferroelectric Thin Film)

  • 차대은;장동훈;강성준;윤영섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2001
  • The fabricated La-modified lead titanate (PLT) thin flirt without poling treatment was investigated for modulation frequency dependence of pyroelectric properties by the dynamic method. $Pb_{1-x}La_{x}Ti_{1-x/4}O_3$PLT (x=0.1) thin film having 10 mol% La content was deposited on a Pt/$TiO_{x}$/$SiO_2$/Si substrate by sol-gel method. The PLT(10) thin film exhibits a relatively excellent dielectric property. The pyroelectric coefficient (p) of the PLT(10) thin film is 6.6 x $10^{-9}$C/$\textrm{cm}^2$.K without frequency dependence. The figure of merits for the voltage responsivity and specific detectivity are 1.03${\times}$$10^{-11}$/C.cm/J and 1.46 x $10^{-9}$C.cm/J, respectively. The PLT(10) thin film has voltage responsivity ($R_{V}$) of 5.15 V/W at 8 Hz. Noise equivalent power (NEP) and specific detectivity (D*) of the PLT(10) thin film are 9.93 x $10^{-8}$W/Hz$^{1/2}$ and 1.81 x $10^{6}$ cmHz$^{1/2}$/W at the same frequency of 100 Hz, respectively. The results means that PLT thin film having 10 mol % La content is suitable for the sensing materials of pyroelectric IR sensors.

  • PDF

초박층 덧씌우기용 아크릴 폴리머 콘크리트의 특성 연구 (Characterization of Acryl Polymer Concretes for Ultra Thin Overlays)

  • 김대영;김태우;이현종;김형배
    • 한국도로학회논문집
    • /
    • 제12권3호
    • /
    • pp.1-8
    • /
    • 2010
  • 본 연구는 콘크리트 슬래브 및 포장도로에 덧씌우기 포장으로 개발된 아크릴 폴리머 콘크리트의 물리 역학적 특성을 평가하기 위하여 수행되었다. 점도시험, 흐름시험, 압축강도시험, 휨 강도시험, 인장강도시험, 선 수축시험, 열팽창계수시험 및 온도변화에 대한 부착성 등 다양한 실내 시험을 실시하였다. 본 연구에서 개발된 아크릴 폴리머 콘크리트의 실내시험 결과 ACI에서 제시하는 모든 기준을 만족하는 것으로 평가되었다. 아크릴 폴리머 콘크리트의 공용성을 평가하기 위해 추가적으로 포장가속시험(APT)을 수행하였으나 등가 단축하중을 15,909,939회를 적용하는 동안 심각한 파손을 확인할 수 없었다. 마지막으로 현장 적용성을 평가하기 위하여 열화현상이 진행된 콘크리트 도로에 10mm의 폴리머 콘크리트 덧씌우기를 적용하였다. 현장 적용 후 미끄럼 저항성, 소음 및 평탄성을 측정한 결과 미끄럼 저항성 및 소음도는 상당히 개선되었으나 평탄성 측정치는 다소 증가하였다. 추후 현장에 적용된 아크릴 폴리머 콘크리트의 정기적인 조사를 통하여 장기 공용성 평가를 수행할 예정이다.

원자력기기 내진해석응답스펙트럼 생성프로그램 개발 (Development of Response Spectrum Generation Program for Seismic Analysis of the Nuclear Equipment)

  • 변훈석;김유철;이준근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.755-762
    • /
    • 2004
  • In our country, when the replacement for individual components of equipment in nuclear power plants is required, establishment of individual criteria i.e. Required Response Spectra(RRS) of seismic test/analysis for the component is very difficult because of the absence of Test Response Spectra(TRS) for the individual component to be replaced, from the existing qualification documents. In this case, it is required to perform the structural analysis for the nuclear equipment including the components to be replaced. After the structural analysis, Analysis Response Spectra(ARS) at the point of the component shall be generated and used for seismic test of the component. However, as of today, no standard program authorized for the response spectra generation by using the structural analysis exists in korea. Because of above reason, the STAR-Egs computer program was developed by using the method which calculates directly the expected response spectrum(frequency vs. acceleration type) of the selected points in the nuclear equipment with input spectrum(Required Response Spectra, RRS), based on the dynamic characteristics of the Finite Element(FE) model that is equivalent to the nuclear equipment. The STAR-Egs controls ANSYS/I-DEAS commercial software and automatically extract modal parameters of the FE model. The STAR-Egs calculates response spectrum using the established algorithm based on the extracted modal parameters, too. Reliance on the calculation result of the STAR-Egs was verified through comparison output with the result of MATLAB commercial software based on the identical algorithm. Moreover, actual seismic testing was performed as per IEEE344-1987 for the purpose of program verification by comparison of the FE analysis results.

  • PDF