• Title/Summary/Keyword: Equivalent noise

Search Result 618, Processing Time 0.03 seconds

A Study on Cooling Effect and Power Control of a Mini Ozonizer (소형 오존발생장치의 전력제어와 냉각효과에 관한 연구)

  • Woo, Sung-Hoon;Park, Seung-Cho;Yoon, Sung-Yoon;Park, Jee-Ho;Woo, Jung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • In this paper, a control method of a mini ozone generator is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2^{\circ}C$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the transient responses with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.

A study on High Frequency DC-DC Converter Drive using a Piezoelectric Transformer (압전 변압기를 이용한 고주파 DC-DC 컨버터 구동에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Gi-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.476-484
    • /
    • 2010
  • Recently, as the piezoelectric transformer technology develops, piezoelectric transformer may become a variable alternative to magnetic transformers in various applications. Because it was have to favorable characteristics such as electromagnetic-noise free, compact size, higher efficiency, and superior power density, linkage flux, noiseless, etc. its resonance frequency was used to output waveform of a sine wave. In this paper, the switching mode power supply of about 87.2[KHz] is driven by the multilayer thickness vibration mode piezoelectric transformer and the DC to DC converter drive circuit using an electrical equivalent circuit is proposed. Also, it was possible to drive power source device of the high-luminance LED by propose circuits.

A Study on the Gaussian-filtered $Q^2PSK$ System for the Digital Mobile Communication System (디지탈 이동통신 시스템을 위한 가우시안 여파 $Q^2PSK$ 방식에 관한 연구)

  • Kim, Kee-Keun;Heo, Dong-Kyu;Kim, Ju-Koang;Ryu, Heung-Gyoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.19-26
    • /
    • 1991
  • $GQ^2PSK$ which is a novel digital mobile communication modulation scheme has been introduced and described. $GQ^2PSK$ is a modulation scheme that bandlimits NRZ digital data with Gaussian filter and modulates it by $Q^2PSK$ scheme which uses two shaping pulses and two carriers which are pairwise quadrature. Thus transmission bit rate can be enhanced and available signal space dimensions are more efficiently utilized, with comparison to the already-existing GMSK, QPSK and OQPSK modulation methods. Via the computer simulation, bit error rate of $GQ^2PSK$ scheme which is bandlimited by gaussian filter to be suitable for digital mobil communication, is lower than that of $Q^2PSK$ by 1.4[dB] in case that the signal-to-noise ration is 0[dB], but we have confirmed that $GQ^2PSK$ modulation scheme is approximately equivalent to the GMSK in the respect of power efficiency, and transmission efficiency of $GQ^2PSK$ is improved to 1.5 times than that of GMSK.

  • PDF

Evaluations of Mn-Ni-Co type thermistor thin film for thermal infrared sensing element (열형 적외선 센싱소자용 Mn-Ni-Co계 써미스터 박막 특성 평가)

  • 전민석;최덕균
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.6
    • /
    • pp.297-303
    • /
    • 2003
  • Mn-Ni-Co type thin films were prepared at various conditions by a rf magnetron sputtering system. At the condition. or substrate temperature of $300^{\circ}C$ and $Ar/O_2$= 10/0, a cubic spinel phase was obtained. When oxygen was included in process gas, a cubic spinel phase was not formed even after the thermal annealing at $900^{\circ}C$. The thermistor thin film had no other elements except Mn, Ni and Co. The infrared reflection spectra of the thermistor thin films showed that the films had somewhat high reflectance for incoming infrared ray with some angle. The etch rate of the thermistor thin films was about 63nm/min at a condition of DI water : $HNO_3$: HCl = 60 : 30 : 10 vol%. The B constant and temperature coefficient of resistance of the thermistor thin films were 3500 K and -3.95 %/K, respectively. The voltage responsivity of the thermistor thin film infrared sensor was 108.5 V/W and its noise equivalent power and specific detectivity were $5.1\times 10^{-7}$ W/$Hz^{-1/2}$ and $0.2\times 10^6$cm $Hz^{1/2}$/W, respectively.

Measurement of Imaging Property of Flat-Panel Detector

  • Matsumoto, Masao;Suekane, Kouji;Maeda, Kouji;Ogata, Yuji;Inamura, Kiyonari;Kanai, Kouzo;Kanamori, Hitoshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.385-388
    • /
    • 2002
  • We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curves, Modulation Transfer Function (MTF), Wiener spectra (WS), Noise Equivalent Quanta (NEQ) and Detective Quantum Efficiency (DQE)) for the direct type and indirect type of Flat-Panel Detector (FPD). First, the digital and overall characteristic curves of the both types of FPD had more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of the direct-type FPD were superior to those of the indirect-type FPD. Third, for identical exposures, the digital and overall WS of the direct-type FPD were similar or worse than those of the indirect-type FPD, and for larger exposure, the digital WS of the both types of FPD were smaller, but overall WS of the both types of FPD were larger. Fourth, the digital and overall NEQ and DQE of the direct-type FPD were worse than both NEQ and DQE of the indirect-type FPD at lower spatial frequencies, but were better at higher spatial frequencies.

  • PDF

Development of Eddy Current Test Probe for Profilometry Inspection of Tube (원형튜브 단면형상검사용 와전류탐촉자 개발)

  • Lee, H.J.;Nam, M.W.;Lee, C.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.262-269
    • /
    • 1997
  • An eddy current probe ($8{\times}1$ multiple-element, surface scan) was successfully designed and fabricated at the KEPRI using the impedance equivalent circuit theory. The probe is intended for the detection of circumferential deformations (cross-section view) of the heat exchanger tubing that can occur due to corrosion, erosion, and denting. Optimum design parameters providing the highest sensitivity and signal-to-noise ratio, such as the coil dimensions, electrical characteristics, and test frequencies, were determined based on initial laboratory experiments conducted on the test specimen (SS304 tubing: OD : 9.68mm, wall-thickness : 0.47mm) containing artificial flaws (e.g., dents and corroded surface on tube OD) using the available Zetec-made probe. Using this parameters, a new probe was made and tested on an unknown specimen. The result indicated that the new probe is capable of detecting the circumferential deformation with the error of ${\pm}0.2%$ (0.022mm) of the tube O.D.

  • PDF

Study on the Brightness Temperature Measurement in the Human Body Using Millimeter-wave Radiometer (밀리미터파 라디오미터를 이용한 인체의 내부 밝기온도 측정에 관한 연구)

  • Jung, Min Kyoo;Kim, Tae Hun;Nah, Seung Wook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.163-167
    • /
    • 2016
  • We have developed a millimeter-wave radiometer system for applications in the fields of medical imaging. In this paper, we introduced the brightness temperature measurement in the human body using Millimeter-wave Radiometer. Calibration of sensitivity of the radiometer system is essential to measure equivalent temperature (brightness temperature) of objects. We have developed, as a calibration source, a new type of black body for the millimeter wave region with temperature control capability. The system noise figure and temperature sensitivity of the system measured using the blackbody are 3.3 dB and 0.1 K, respectively. The brightness temperature of human body through clothes was measured to be around $38^{\circ}$[C].

CMOS Programmable Interface Circuit for Capacitive MEMS Gyroscope (MEMS 용량형 각속도 센서용 CMOS 프로그래머블 인터페이스 회로)

  • Ko, Hyoung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.13-21
    • /
    • 2011
  • In this paper, the CMOS programmable interface circuit for MEMS gyroscope is presented, and evaluated with the MEMS sensing element. The circuit includes the front-end charge amplifier with 10 bit programmable capacitor arrays, 9 bit DAC for accurate offset calibration, and 10 bit PGA for accurate gain calibration. The self oscillation loop with automatic gain control operates properly. The offset error and gain error after calibration are measured to be 0.36 %FSO and 0.19 %FSO, respectively. The noise equivalent resolution and bias instability are measured to be 0.016 deg/sec and 0.012 deg/sec, respectively. The calibration capability of this circuit can reduce the variations of the output offset and gain, and this can enhance the manufacturability and can improve the yield.

A 300 GHz Imaging Detector and Image Acquisition Based on 65-nm CMOS Technology (65-nm CMOS 300 GHz 영상 검출기 및 영상 획득)

  • Yoon, Daekeun;Song, Kiryong;Rieh, Jae-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.791-794
    • /
    • 2014
  • In this work, a 300 GHz imaging detector has been developed and image has been acquired in a 65-nm CMOS technology. The circuit was designed based on the square-law of MOSFET devices. The fabricated detector exhibits a maximum responsivity of 2,270 V/W and minimum NEP of $38pW/Hz^{1/2}$ at 285 GHz, and NEP< ${\sim}200pW/Hz^{1/2}$ for 250~305 GHz range. The chip size is $400{\mu}m{\times}450{\mu}m$ including the probing pads and a balun, while the core of the circuit occupies only $150{\mu}m{\times}100{\mu}m$.

Characteristic Measurements of the Pyroelectric IR Sensor (초전형 IR Sensor의 특성 측정)

  • Kim, Hyun-Ki;Shin, Kyeong-Sik;Kim, Young-Kook;Kim, Tae-Yun;Lee, Sang-Rel;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.92-95
    • /
    • 2003
  • 초전형 센서의 특성 평가 방법에는 여러 가지 방법들이 존재하며, 이에 대한 표준화된 특성 평가방법의 개발이 필요로 한다. 측정 평가의 방법이나 조건 등에 따라서 평가 결과가 크게 변할 수 있는 사항들이며, 따라서 국내 뿐 아니라 대외적으로 다른 나라의 제품들과 신뢰성을 가지고 경쟁을 하기 위해서는 평가항목이나 평가방법의 표준화가 절실하게 요구된다. 초전형 적외선 센서를 평가하는 항목에는 기본적으로 입력에 대한 출력신호의 크기를 평가하는 감도(responsivity), 잡음과 관련되어 센서가 검출할 수 있는 최소의 신호를 나타내는 NEP(Noise Equivalent Power)와 이것을 센서의 감지 면적으로 정규화 시킨 검출능(detectivity), 응답 속도를 나타내는 시정수(time constant)가 있으며 이러한 항목들이 표준화의 대상이 된다. 본 실험에서는 기존의 상용화된 센서들을 가지고 초전형 적외선 센서의 특성을 측정 하였다. 특성을 측정할 때 다른 요인들 보다 노이즈로 인한 영향이 상당히 크므로 측정시 노이즈 발생 문제를 해결하는 방법으로 본 논문에서는 센서 측정에 사용되는 증폭 회로에서 노이즈를 해결하려고 하였다. 우리는 증폭 회로구성에서 노이즈를 제거하기 위해서 신호입력단과 전압 압력에 잡음제거 필터로 R, C를 사용하였다. 회로설계로 제작된 증폭회로와 측정 장치를 가지고 측정을 한 결과 센서의 감도는 $3.0mV_{p-p}$, 응답시간은 20ms정도의 값으로 가장 일반적인(typical) 값을 보인다.

  • PDF