• Title/Summary/Keyword: Equivalent noise

Search Result 616, Processing Time 0.025 seconds

A study on design of instantaneous field of view of rosette scanning infrared seeker (로젯 주사 적외선 탐색기의 순시 시계 설계에 관한 연구)

  • 장성갑;홍현기;한성현;최종수
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.7
    • /
    • pp.86-94
    • /
    • 1998
  • The rosette-scan seeker is a device mounted on the infrared guided missile. It offers the positions and iamges of target to missiles servo system by scanning a space about target in rosette pattern with a single detector. An instantaneous field of view (IFOV), which is a diameter of a detector moving along the path of the rosette pattern, has the property that its smaller size provide the less interference of background signals and detector noise. If its size is too small to voer the total field of view (TFOV), however, it produces the invisible regions in the TFOV. In this case, the invisible regions cause the performance of the seeker to deteriorate. For full scan-coverage, it is necessary to design the small IFOV without the invisible regions in the TFOV, as possible. In this paper, we propose the new method of designing the smaller IFOV than the conventional method and verify full coverage of the scanned region. By comparing the nose equivalent flux density (NEFD) of the proposed method with the that of the conventional one, we confirm that the former is better than the latter in terms of performance.

  • PDF

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • v.36 no.5
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

Dynamic response of adjacent structures connected by friction damper

  • Patel, C.C.;Jangid, R.S.
    • Earthquakes and Structures
    • /
    • v.2 no.2
    • /
    • pp.149-169
    • /
    • 2011
  • Dynamic response of two adjacent single degree-of-freedom (SDOF) structures connected with friction damper under base excitation is investigated. The base excitation is modeled as a stationary white-noise random process. As the force-deformation behavior of friction damper is non linear, the dynamic response of connected structures is obtained using the equivalent linearization technique. It is observed that there exists an optimum value of the limiting frictional force of the damper for which the mean square displacement and the mean square absolute acceleration responses of the connected structures attains the minimum value. The close form expressions for the optimum value of damper frictional force and corresponding mean square responses of the coupled undamped structures are derived. These expressions can be used for initial optimal design of the friction damper for connected structures. A parametric study is also carried out to investigate the influence of system parameters such as frequency ratio and mass ratio on the response of the coupled structures. It has been observed that the frequency ratio has significant effect on the performance of the friction damper, whereas the effects of mass ratio are marginal. Finally, the verification of the derived close from expressions is made by correlating the response of connected structures under real earthquake excitations.

State Estimation Technique for VRLA Batteries for Automotive Applications

  • Duong, Van Huan;Tran, Ngoc Tham;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.238-248
    • /
    • 2016
  • The state-of-charge (SOC) and state-of-health (SOH) estimation of batteries play important roles in managing batteries for automotive applications. However, an accurate state estimation of a battery is difficult to achieve because of certain factors, such as measurement noise, highly nonlinear characteristics, strong hysteresis phenomenon, and diffusion effect of batteries. In certain vehicular applications, such as idle stop-start systems (ISSs), significant errors in SOC/SOH estimation may lead to a failure in restarting a combustion engine after the shut-off period of the engine when the vehicle is at rest, such as at a traffic light. In this paper, a dual extended Kalman filter algorithm with a dynamic equivalent circuit model of a lead-acid battery is proposed to deal with this problem. The proposed algorithm adopts a battery model by taking into account the hysteresis phenomenon, diffusion effect, and parameter variations for accurate state estimations of the battery. The validity of the proposed algorithm is verified through experiments by using an absorbed glass mat valve-regulated lead-acid battery and a battery sensor cable for commercial ISS vehicles.

Design of A Self-Oscillating Mixer Using A Novel DGS (새로운 DGS구조를 이용한 자기 발진 혼합기 설계)

  • Joung, Myung-Sup;Kim, Jong-Ok;Park, Jun-Seok;Lim, Jae-Bong;Kim, Heong-Seok;Cho, Hong-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1958-1960
    • /
    • 2003
  • Here we describe a unique self-oscillating mixer (SOM) design using a modified defected ground structure (DGS) for down-converter. Proposed SOM is consisted of self-oscillator, which can produce negative resistance and select resonance frequency, and input/output matching filter. As the advantage of this SOM can be reused by module that mix signals with transistor that is used to oscillator, it is simply and low-costly designed Also, there is easy advantage to be applied in RFIC/ MMIC technology because it offers excellent high Q value in spite of using micro-strip structure. Designed self-oscillating frequency is 1.04GHz and RF frequency established is 0.8GHz. It was achieved 20dB conversion loss and phase noise of -95dBc/Hz at 100KHz offset frequency over intermediate frequency (IF). The equivalent circuit parameters for DGS are extracted by using a three dimensional EM simulator and simple circuit analysis method.

  • PDF

Investigation of ITU Radio Regulations Regarding KPS Service Band

  • Subin Lee;Kahee Han;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.177-184
    • /
    • 2023
  • In order to reserve frequency bands for stable operation of the Korean Positioning System (KPS), it must be demonstrated that the impact of interference caused by KPS on other services operating in the same bands is tolerable. The International Telecommunication Union (ITU) provides the radio regulations and a compatibility assessment methodology for the coexistence of different services in limited frequency resources. The purpose of this paper is to investigate the radio regulations regarding the compatibility issues between the KPS and other services sharing the same frequency bands. The results of the investigation show that the RNSS system can be operated in the L5-band under the condition that the Power Flux Density (PFD) and Aggregated Equivalent PFD (AEPFD) thresholds specified in the radio regulations are met. In addition, the ITU recommends that the interference-to-noise ratio (INR) protection criteria be met to prevent degradation of the performance of radar systems operating in the L2/L6-band. In the case of the S-band, coordination of allocations for RDSS space stations with respect to terrestrial services is not required if the PFD does not exceed regulated thresholds regulated by ITU.

Design of X-band Core Chip Using 0.25-㎛ GaAs pHEMT Process (0.25 ㎛ GaAs pHEMT 공정을 이용한 X-대역 코아-칩의 설계)

  • Kim, Dong-Seok;Lee, Chang-Dae;Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.336-343
    • /
    • 2018
  • We herein present the design and fabrication of a Rx core chip operating in the X-band (10.5~13 GHz) using Win's commercial $0.25-{\mu}m$ GaAs pHEMT process technology. The X-band core chip comprises a low-noise amplifier, a four-bit phase shifter, and a serial-to-parallel data converter. The size is $1.75mm{\times}1.75mm$, which is the state-of-the-art size. The gain and noise figure are more than 10 dB but less than 2 dB, and both the input and output return losses are less than 10 dB. The RMS phase error is less than $5^{\circ}$, and the P1dB is 2 dBm at 12.5 GHz, the performance of which is equivalent to other GaAs core chips. The fabricated core chip was packaged in a QFN package type with a size of $3mm{\times}3mm$ for the convenience of assembly. We confirmed that the performance of the packaged core chip was almost the same as that of the chip itself.

A Study on the Pyroelectric Properties of PZT(30/70) Thick film Prepared by Using 1,3 Propanediol (1,3 Propanediol을 이용해 제작된 PZT(30/70) 후막의 초전특성에 관한 연구)

  • Song, Kum-Suck;Chang, Dong-Hoon;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.9-15
    • /
    • 2004
  • PZT(30/70) thick film was fabricated by using 1,3 propanediol-based sol-gel method. Prepared film of pyroelectric property was investigated by Dynamic method of modulation frequency dependence. Pyroelectric coefficient was obtained about $5.0{\times}10^{-8}\;C/cm^2{\cdot}K$. The figure of merits for voltage responsively and specific detectivity were $3.4{\times}10^{-11}\;C{\cdot}cm/J$ and $5.9{\times}10^{-9}\;C{\cdot}cm/J$, respectively, because of relative high-dielectric constant and high-pyroelectric coefficient. Voltage responsively was increased at low modulation frequency and it was decreased at high modulation frequency. Voltage responsively was maximum 1.84 V/W at 10Hz. As Johnson noise is dominant, Noise voltage was increased nearly proportional to $f^{-1/2}$. Noise equivalent power and specific detectivity were $2.83{\times}10^{-7}\;W/Hz^{1/2}$ and 3.13{\times}10^5\;cm{\cdot}Hz^{1/2}/W$ the same frequency at 80Hz, respectively.

A Microwave Push-Push VCO with Enhanced Power Efficiency in GaInP/GaAs HBT Technology (향상된 전력효율을 갖는 GaInP/GaAs HBT 마이크로파 푸쉬-푸쉬 전압조정발진기)

  • Kim, Jong-Sik;Moon, Yeon-Guk;Won, Kwang-Ho;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.9
    • /
    • pp.71-80
    • /
    • 2007
  • This paper presents a new push-push VCO technique that extracts a second harmonic output signal from a capacitive commonnode in a negativegm oscillator topology. The generation of the $2^{nd}$ harmonics is accounted for by the nonlinear current-voltage characteristic of the emitter-base junction diode causing; 1) significant voltage clipping and 2) different rising and falling time during the switching operation of core transistors. Comparative investigations show the technique is more power efficient in the high-frequency region that a conventional push-push technique using an emitter common node. Prototype 12GHz and 17GHz MMIC VCO were realized in GaInP/GaAs HBT technology. They have shown nominal output power of -4.3dBm and -5dBm, phase noise of -108 dBc/Hz and -110.4 dBc/Hz at 1MHz offset, respectively. The phase noise results are also equivalent to a VCO figure-of-merit of -175.8 dBc/Hz and -184.3 dBc/Hz, while dissipate 25.68mW(10.7mA/2.4V) and 13.14mW(4.38mA/3.0V), respectively.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF