• 제목/요약/키워드: Equivalent lens

Search Result 77, Processing Time 0.055 seconds

Design of an 8× Four-group Zoom System without a Moving Group by Considering the Overall Length

  • Park, Sung Min;Lee, Jea-Woo;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.104-113
    • /
    • 2022
  • We present a method to count the overall length of the zoom system in an initial design stage. In a zoom-lens design using the concept of the group, it has been very hard to precisely estimate the overall length at all zoom positions through the previous paraxial studies. To solve this difficulty, we introduce Teq as a measure of the total track length in an equivalent zoom system, which can be found from the first order parameters obtained by solving the zoom equations. Among many solutions, the parameters that provide the smallest Teq are selected to construct a compact initial zoom system. Also, to obtain an 8× four-group zoom system without moving groups, tunable polymer lenses (TPLs) have been introduced as a variator and a compensator. The final designed zoom lens has a short overall length of 29.99 mm, even over a wide focal-length range of 4-31 mm, and an f-number of F/3.5 at wide to F/4.5 at tele position, respectively.

Achromatic and Athermal Design of a Mobile-phone Camera Lens by Redistributing Optical First-order Quantities

  • Tae-Sik Ryu;Sung-Chan Park
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.273-282
    • /
    • 2023
  • This paper presents a new method for redistributing effectively the first orders of each lens element to achromatize and athermalize an optical system, by introducing a novel method for adjusting the slope of an achromatic and athermal line. This line is specified by connecting the housing, equivalent single lens, and aberration-corrected point on a glass map composed of available plastic and glass materials for molding. Thus, if a specific lens is replaced with the material characterized by the chromatic and thermal powers of an aberration-corrected point, we obtain an achromatic and athermal system. First, we identify two materials that yield the minimum and maximum slopes of the line from a housing coordinate, which specifies the slope range of the line spanning the available materials on a glass map. Next, redistributing the optical first orders (optical powers and paraxial ray heights) of lens elements by moving the achromatic and athermal line into the available slope range of materials yields a good achromatic and athermal design. Applying this concept to design a mobile-phone camera lens, we efficiently obtain an achromatic and athermal system with cost-effective material selection, over the specified temperature and waveband ranges.

Fabrication of the focal length and distortion measurement system (초점길이 및 왜곡수차 측정장치 제작)

  • 조현모
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

Optical System Design Composed of Spherical SELFOC Lens and Aspherical Plastic Lens for Mobile Phone Camera (1매의 구면 SELFOC 렌즈와 1매의 비구면 플라스틱 렌즈로 구성된 카메라폰용 광학계의 설계)

  • Lee, Yong-Sun;Lee, Jong-Ung
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.108-115
    • /
    • 2008
  • We designed optical systems for a mobile phone camera using a spherical SELFOC lens and an aspherical plastic lens. Since the radial index distribution gives an additional design parameter for optical design, an aspheric lens could be replaced by a spherical lens. The imaging performances of the design were compared with conventional 2P design composed of two aspherical plastic lenses. In the first stage of study, we designed 1GRIN 1P lenses by using commercially available SELFOC materials. But, the conventional 2P lenses had better performance than the 1GRIN 1P lenses. In the 1GRIN 1P designs, the performance depends on index variation of GRIN material, the larger variation gives the better performance. Hence, we tried to design by using fictitious GRIN materials which have large index variation. We found if the index variation could be increased to about 3 times that of currently available SELFOC materials, the 1GRIN 1P lens will have equivalent or better performance than the conventional 2P design.

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.

Design of a Catadioptric System with Corrected Color Aberration and Flat Petzval Curvature Using a Graphically Symmetric Method

  • Lim, Tae-Yeon;Park, Sung-Chan
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.324-331
    • /
    • 2018
  • This paper describes a symmetric method for determining a combination of element power and optical material to design a catadioptric system with corrected color aberration and flat Petzval curvature. To graphically obtain the solutions, a glass chart containing the Abbe number, the refractive index, and the optical power, which are closely related to these aberrations, is suggested. First, we recompose an optical system as a doublet of the specific lens and an equivalent single lens, and then locate both lenses on lines that are symmetric to each other on a glass chart, through changing the lens parameters effectively. Utilizing this method, an achromatic catadioptric system with flat Petzval curvature is obtained.

Non-Radiative Dielectric(NRD) Rotman Lens with Gap-Coupled Unidirectional Dielectric Radiator(UDR) (갭 결합된 단향성 유전체 방사체를 적용한 비방사 유전체 로트만 렌즈)

  • 이재곤;이정해
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1269-1275
    • /
    • 2003
  • In this paper, nonradiative dielectric(NRD) rotman lens with a gap-coupled unidirectional dielectric radiator(UDR) has been designed. Gap-coupled UDR is structurally suitable for NRD rotman lens. We have optimized NRD rotman lens for minimizing side-lobe, and calculated design parameters of UDR such as length of resonator and distance of gap using an equivalent circuit model of an evanescent NRD guide. Experimental prototype of UDR is fabricated and measured at the center frequency of 38 GHz. The simulated S-parameter and far-field radiation beam pattern of UDR show good agreements with measured data. Finally, total beam pattern of NRD rotman lens of multi-beam feed has been obtained using a measured pattern of UDR and array factor of NRD rotman lens. The obtained beam pattern shows remarkably suppressed side-lobe.

linical Performance Analysis of Lens for Improving VDT Syndrome (VDT 증후군 개선을 위한 렌즈의 임상성능 분석)

  • Ryu, Geun-Chang;Park, Ji-Hoon;Jun, Jin;Jin Moon-Seog;Chae, Soo-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.45-51
    • /
    • 2009
  • Purpose: The purpose of this study is to compare and analyze the survey results of clinical performance and visual problem, and the survey were carried out before and after of VDT working for 4 hours by wearing functional lens designed for improving VDT syndrome and single-vision lens. Methods: We tested near & far visual acuity, change of spherical equivalent, near point of accommodation, near point of convergence, AC/A ratio, accommodative facility and survey of subjective symptoms to visual problem of before and after VDT working for 4 hours after wearing single-vision lens and functional lens subjected on 30 males and females in the age of 20 to 45. Results: When wearing functional lens comparing to single-vision lens, near visual acuity, near point of accommodation, near point of convergence, and accommodative facility are significantly improved. It is investigated that average scores of 10 items to visual problem after VDT working for 4 hours are 3.63${\pm}$0.75 at single-vision lens and 4.69 ${\pm}$ 0.83 at functional lens, and therefore functional lens is significantly improved. Conclusions: It is thought that functional lens is an excellent lens which helps to improve accommodative function and visual problem after VDT working for 4 hours than single-vision lens.

  • PDF

Effects of the Progression Control of Myopia on Myopia Control Lenses and Single Vision Lenses (Myopia Control 렌즈와 Single Vision 렌즈의 근시진행 조절 효과)

  • Jung, Ji-Won;Lee, Ki-Seok;Yoo, Wang-Keun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • Purpose: This paper was to study the clinical effects of moderating myopia by comparing the myopia control lens, which was being recently recognized as a method of inhibiting the progression of myopia, with the wearers of single vision lens. Methods: Using 56 subjects between the ages of 8-15 years (112 eyes) with myopia in the areas of City of Daegu and Gyeongsangbuk Province as study subjects, refractive error, axial length, near point of convergence and accommodative near point were measured and compared a total of 3 times at the baseline, after 1-month and after 6-months. Results: For refractive error, suppression and mitigation were seen in the progression of spherical equivalent when MC lens was worn, as compared to using SV lens, and, when axial length MC lens was worn, the axial progression was significantly suppressed and delayed (p < 0.05). The near point of convergence became shorter with the use of MC lens, and the amplitude of convergence was improved when MC lens was worn. Accommodative near point became shorter with the use of MC lens, and focus ability was significantly improved (p <0.05). Conclusions: It was shown that MC lens, compared to SV lens, could alleviate myopia progression in school-age children and youth. It is considered that MC lens can be used as a useful therapy for the inhibition of myopia progression in the increasing number of myopic children and adolescents.