• Title/Summary/Keyword: Equivalent k

Search Result 7,556, Processing Time 0.055 seconds

Behavior of NO3-N and Accompanying Cations Derived from Urea under Upland Condition -I. Leaching of NO3-N and Accompanying Cations (요소유래(尿素由來) NO3-N 및 동반(同伴) 양(陽)이온의 토양(土壤) 중 행동(行動) -I. NO3-N 동반(同伴) 양(陽)이온의 용탈(溶脫))

  • Yun, Sun-Gang;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.1
    • /
    • pp.15-20
    • /
    • 1994
  • Lysimeter experiments were conducted to elucidate the behavior of $NO_3-N$ derived from urea applied at different rates and accompanying cations in soils and to further provide fundamental information of rational nitrogen-fertilizer management. Urea was applied at rates of 0, 7, 14, 21, 28 and 35kg N/10a to sandy loam pakced into PVC cylindrical lysimeter(vol. : $0.187m^2$, area $0.43m^2$). Leachates from the lysimeter with or without grass grown were collected periodically and analyzed for $NO_3$ and cations. Grass growth and yield responses to N fertilization were also examined. Dry matter yield and nitrogen uptake increased with the urea application rate. The amount of leachate from the lysimeter was negatively correlated with urea application ratesl($r=-0.95^{**}$). The nitrate leaching loss with grass grown was 230 g N/10a at the maximum rate of 35kg N/10a, but the highest leaching loss was observed as 1,607 g N/10a from the bare plot. Increase in urea application rates decreased significantly leaching losses of Ca, Mg, K and Na(>0.01). The highest leaching loss from the bare plot was observed for Ca but only 6.5% of exchangeable form and 14.0% for K from the grass plot respectively. Equivalent ratio of cations to nitrate leached were 3.2 % for the bare plot and the ratio for the grass plot increased with the urea application rate, ranging from 18.6 to 32.7%.

  • PDF

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.

Studies for Antibiotic Free Chicken Production Using Water Extracts from Artemisia capillaris and Camellia sinensis (인진쑥 및 녹차 추출물을 이용한 무항생제 닭고기 생산 연구)

  • Kim, Dong-Wook;Kim, Ji-Hyuk;Kang, Geun-Ho;Kang, Hwan-Ku;Park, Sung-Bok;Park, Jae-Hong;Bang, Han-Tae;Kim, Min-Ji;Na, Jae-Cheon;Chae, Hyun-Suk;Choi, Hee-Chul;Suh, Ok-Suk;Kim, Sang-Ho;Kang, Chang-Won
    • Food Science of Animal Resources
    • /
    • v.30 no.6
    • /
    • pp.975-988
    • /
    • 2010
  • Two experiments were conducted to determine whether water extracts from Artemisia capillaries (A. capillaries) and Camellia sinensis (C. sinensis) could be used as alternatives to antibiotic growth promoters in broiler feed. The experiment 1 was verified their chemical composition, extracts yields, total phenolic compounds concentration, antioxidant activity, antimicrobial activity, and chicken splenocytes proliferation through in vitro test. The extract yields of A. capillaries and C. sinensis were 26.5 and 16.8%, respectively. Total phenolic compounds concentrations of them expressed as gallic acid equivalent were 15.28 and 26.74 mg/mL, respectively. Electron donating abilities of them expressed as $SC_{50}$ showing 50% DPPH radical scavenging were 0.30 and 0.06 mg, respectively. Bacterial inhibitory rates of them against Escherichia coli, Staphylococcus aureus, and Salmonella Typhimurium were ranged from 42.1 to 52.3% and from 21.6 to 33.7%, respectively. And, these extracts increased proliferation of chicken splenocytes. Especially, A. capillaris was more excellent than Echinacea and Concanavalin A known as T-cell stimulator. The experiment 2 was investigated their effects on growth performance, relative organ weight, cecal microflora, blood biochemical parameters, and splenic cytokines mRNA expression in broiler chicks. Four hundred eighty 1-day-old male broiler chicks (Ross 308) were divided in to 4 treatment groups with 4 replicates of 30 birds in each group: NC (control, no antibiotics), PC (avilamycin, 10 ppm; salinomycin, 60 ppm), AC (A. capillaries, 100 ppm), and CS (C. sinensis, 100 ppm); treatments were administered through water supplementation. Final body weight was significantly higher in all treated groups than in NC (p<0.05). Cecal Salmonella numbers were significantly or somewhat decreased in all treated groups than in NC (p<0.05). The relative weights and lengths of the small intestine were more significantly decreased in the PC and AC groups than in the other groups. Cecal Salmonella numbers were significantly or somewhat decreased in all treated groups than in the NC group (p<0.05). The contents of total cholesterol, aspatate aminotransferase, and alanine aminotransferase in blood serum were more significantly decreased in all treated groups than in NC (p<0.05). In conclusion, these results suggested the possibility that these extracts could serve as alternatives for antibiotic growth promoters.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

A Study of Accommodative Response on Emmetropia (정시안의 조절반응량에 관한 연구)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Joo, Seog-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.187-192
    • /
    • 2006
  • The purpose of this research was to measurement real accmmnodative response amount of emmetropia using both eyes open-view auto-refractometer. We classified 377(male 146, female 231)eyes showing good naked vision at least 1.0, with a spherical equivalent refraction of under ${\pm}0.50D$ and cylindercal refraction of under -0.75D, from 10 to 59(mean $25.8{\pm}12.4$) years into 5 groups with 10 year interval and analyzed change of the near astigmatism and accommodative response amount to distinction of age. Age comparison, total mean 1.47D, 10 years age group 1.63D, 20 years age group 1.57D, 30 years age group 1.71D, 40 years age group 0.97D, and 50 years age group 0.05D. It was no difference between 10 to 30 years age group, But it showed the decre8.se which is remarkable from above 40 years age group and it does not almost response from above 50 years age group. Sexual difference, the man appeared some highly in male(mean $26.4{\pm}12.3$ years) 1.56D m female(mean $26.4{\pm}12.3$) 1.43D. Near-astigmatism power change, mean +0.12D, 10 years age group +0.06D, 20 years age group +0.16D, 30 years age group +0.09D, 40 years age group +0.05D, and 50 years age group +0,06D. No significant difference of astigmatism powers among the an groups, but from all years age group the astigmatism power appeared more highly far-astigmatism than near-astigmatism. Near-astigmatism axis change in the far-astigmatism changes at under ${\pm}10^{\circ}$ 103 eyes, above ${\pm}10^{\circ}$ rotation clockwise direction 108 eyes, above ${\pm}10^{\circ}$ rotation counter-clockwise direction 101 eyes. It was analyzed near-astigmatism axis change.

  • PDF

Analysis on the Snow Cover Variations at Mt. Kilimanjaro Using Landsat Satellite Images (Landsat 위성영상을 이용한 킬리만자로 만년설 변화 분석)

  • Park, Sung-Hwan;Lee, Moung-Jin;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.4
    • /
    • pp.409-420
    • /
    • 2012
  • Since the Industrial Revolution, CO2 levels have been increasing with climate change. In this study, Analyze time-series changes in snow cover quantitatively and predict the vanishing point of snow cover statistically using remote sensing. The study area is Mt. Kilimanjaro, Tanzania. 23 image data of Landsat-5 TM and Landsat-7 ETM+, spanning the 27 years from June 1984 to July 2011, were acquired. For this study, first, atmospheric correction was performed on each image using the COST atmospheric correction model. Second, the snow cover area was extracted using the NDSI (Normalized Difference Snow Index) algorithm. Third, the minimum height of snow cover was determined using SRTM DEM. Finally, the vanishing point of snow cover was predicted using the trend line of a linear function. Analysis was divided using a total of 23 images and 17 images during the dry season. Results show that snow cover area decreased by approximately $6.47km^2$ from $9.01km^2$ to $2.54km^2$, equivalent to a 73% reduction. The minimum height of snow cover increased by approximately 290 m, from 4,603 m to 4,893 m. Using the trend line result shows that the snow cover area decreased by approximately $0.342km^2$ in the dry season and $0.421km^2$ overall each year. In contrast, the annual increase in the minimum height of snow cover was approximately 9.848 m in the dry season and 11.251 m overall. Based on this analysis of vanishing point, there will be no snow cover 2020 at 95% confidence interval. This study can be used to monitor global climate change by providing the change in snow cover area and reference data when studying this area or similar areas in future research.

A Study on the Breeding Density and Diet of Magpie Pica pica in Jeju Island1a (제주도에 서식하는 까치 Pica pica의 번식 밀도 및 식이물에 관한 연구)

  • Park, Joo-Yeon;Kim, Byoung-Soo;Oh, Hong-Shik
    • Korean Journal of Environment and Ecology
    • /
    • v.22 no.6
    • /
    • pp.648-657
    • /
    • 2008
  • This research was conducted to investigate the breeding density and seasonal food items of the magpies in Jeju Island and the near-manned islets. The examination of nest distribution to determine breeding density was performed during breeding season from February 2006 to April 2008, and that of food items from May 2006 to February 2008. A total of 2,113 nests were found across Jeju Island, the average density was $1.33\;nest/km^2$, and the magpies were distributed up to 600 meters above the sea level. The nest density was the highest in the central areas of Jeju Island, with 688 nests at $3.61\;nest/km^2$, while that in the eastern areas was the lowest, with 214 nests at $0.66\;nest/km^2$. In terms of the number of nests depending on the height above the sea level, 1,172 nests, which was equivalent to the density of $1.85\;nest/km^2$, was observed below 100m and highest among the intervals of height, but 16 nests found at 500-600m were the lowest, corresponding to $0.20\;nest/km^2$. The number of nests found in the manned islets near Jeju Island was eight in Biyang-do with the density of $15.38\;nest/km^2$, nine in U-do with $1.49\;nest/km^2$, and one in Gapa-do with $1.15\;nest/km^2$, whereas none of nests were observed in Mara-do. The contents of stomach consisted of 17 types of prey sources including countless bones, eggshells, plants, and seed, most of which were the individuals of the order Coleoptera. In spring and summer, the foraging frequency for invertebrate animals such as insects was high, but less than 30% in winter. In contrast, the magpies preyed upon plants and seeds at the frequency of 10% and 30%, respectively, in spring, while the foraging frequencies for both of them were 100% in winter and higher than any of other seasons. Eggshells and bones of birds were also detected infrequently. If the density of the magpies, which may play role as the upper predator within the ecosystem, increases, it would be expected to affect directly the reduction of the number of the species and population of endemic animals such as small birds and reptiles, etc. Therefore, it is considered that long-term monitoring for the density of the magpies and precaution is prerequisite to minimize adverse effects on ecosystem.

Physicochemical Quality Characteristics and Antioxidant Activity of Wasabi (Wasabia japonica) Leaf and Petiole Extracts (고추냉이 잎, 엽병 추출물의 이화학적 특성과 항산화 활성)

  • Sung, Eun Hee;Shin, Se Mi;Kang, Yoon-Han
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.3
    • /
    • pp.335-342
    • /
    • 2017
  • In this study, we investigated the physicochemical quality characteristics and antioxidant activities of water extracts ($20^{\circ}C$ and $95^{\circ}C$) against different parts (leaf and petiole) from Wasabia japonica (wasabi). Water extracts were divided into six types of wasabi powders: leaf hot air dried (LD), petiole hot air dried (PD), whole (leaf+petiole) hot air dried (WD), leaf steamed and hot air dried (LSD), petiole steamed and hot air dried (PSD), and whole steamed and hot air dried (WSD). Turbidity was higher in wasabi $20^{\circ}C$ water extracts than in $95^{\circ}C$ hot water extracts. Browning degree was higher in wasabi leaf extracts than in petiole extracts. The pH of hot water extraction was lower than that of room temperature extraction. Wasabi extracts did not show much difference in Hunter's color values according to extraction temperature, expected that b value of yellowness was significantly higher in leaf extracts than in petiole extracts. Carbazole pectin contents of leaf extracts were significantly higher than in petiole extracts, however water soluble pectin was higher in petiole extracts. The total polyphenol contents of LD20 and LD95 were 1,561.43 mg gallic acid equivalent (GAE)/100 g and 1,163.02 mg GAE/100 g, respectively, and total polyphenols decreased during hot water extraction. Extracts from different parts of wasabi showed a significant difference in total flavonoid contents. Total flavonoid contents of LD20, LD95, PD20, and PD95 were 554.44 mg/100 g, 396.65 mg/100 g, 55.42 mg/100 g, and 47.68 mg/100 g, respectively. In the sensory evaluation, LD95 extract showed significantly higher values than other samples in terms of color, flavor, taste, mouth feeling, and overall acceptability. In the analysis of sourness, saltiness, umami, sweetness, and bitterness taste by an electronic tongue, the sourness values of LD20 and PSD95, saltiness values of WSD20 and WSD95, and umami values of PD20 and PD95 were significantly higher than other extracts. The results of this study suggest that wasabi leaf and petiole extracts enhance qualities and antioxidant activities when used different parts together.